journal article·2025-01-01

Inhibition of Copper Corrosion by Corrosion Inhibitors in the Presence of Scale Dispersants

Kaho Sugiura, Yuna Yamaguchi, Toyohiro Arima, Yuma Kano, Takato Sasaki, Itaru Ikeda, Takashi Iyasu, Yutaka Yamada, Osamu Sakurada

MATERIALS TRANSACTIONS· Volume 66· Issue 1
Publisher page

Abstract

We have been examined the suppression of pitting corrosion in copper tube used for heat transfer in cooling water systems with absorption chillers. The corrosion was caused by the relationship between the carbon film on the copper tube surface and the water quality flowing through the tube. Phosphonic acid, and benzotriazole (BTA) were used as water treatment chemical due to suppress pitting corrosion. We reported silicate ion and calcium ion are effective for the corrosion resistance of copper in the presence of phosphonic acid, and also studied the effect of pH and carbon film. In this study, BTA was added to the system containing these three factors, and the effect of BTA on the corrosion resistance of copper tubes was investigated using electrochemical measurements. As the concentration of BTA increased, the current density was suppressed and the BDP became larger. No significant difference was observed with pH, but there was a difference with and without carbon film. From these results, it was considered that corrosion inhibition is more effective with increasing BTA concentration.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Material Properties and Applications · Environmental Chemistry and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry and Biomolecular Science, Faculty of Engineering, Gifu University

Technical Research Laboratory, Dai-Dan Co., Ltd.

Technical Support Department, Kurita Water Industries Ltd.

Daiwa Techno Co., Ltd.

References (9)

Show source-provided references
1. 1) T. Iyasu, M. Kuratani, I. Ikeda, N. Tanaka, Y. Yamada and O. Sakurada: A Study of Water Treatment Chemical Effects of Type I′′ Pitting Corrosion of Copper Tubes, Mater. Sci. Appl. 11 (2020) 494–504. doi:10.4236/msa.2020.11703410.4236/msa.2020.117034 ↗
2. 2) M. Kuratani, I. Ikeda, T. Iyasu, N. Tanaka, T. Katsuragawa, S. Matsumura, Y. Yamada and O. Sakurada: Corrosion Survey of Cooling Water Pipes with Pattern Diagrams of Water Quality, J. Japan Inst. Copper 60 (2021) 144–149. doi:10.34562/jic.60.1_14410.34562/jic.60.1_144 ↗
3. 3) T. Sasaki, Y. Kano, M. Kuratani, T. Iyasu, N. Tanaka, Y. Yamada and O. Sakurada: Evaluation of Cooling Water System Water Treatment Chemical on Anticorrosion Effectiveness of Copper Tubes Using Pattern Diagrams of Water Quality, Proceedings of JSCE Materials and Environments, (2021) pp. 121–122 (in Japanese).
4. 4) Y. Yamaguchi, T. Sasaki, M. Kuratani, T. Iyasu, Y. Yamada and O. Sakurada: Effects of Silicate on Corrosion Resistance of Copper Tubes by Cooling Water System Water Treatment Chemical, J. Japan Inst. Copper 61 (2022) 154–158. doi:10.34562/jic.61.1_15410.34562/jic.61.1_154 ↗
5. 5) Y. Yamada, K. Nagata and K. Tagashira: Pitting Corrosion of Copper Tube in a Phosphonic Acid Solution, Sumitomo Light Metal Technical Reports 33 (1992) 222–229.
6. 6) Y. Yamaguchi, M. Kuratani, T. Sasaki, T. Iyasu, Y. Yamada and O. Sakurada: Effect of Silicate and Ca Hardness on Corrosion Resistance of Copper Tubes in the Presence of Phosphonic Acid, Proceedings of JSCE Materials and Environments, (2022) pp. 57–58 (in Japanese).
7. 7) Y. Yamaguchi, Y. Kano, I. Ikeda, T. Iyasu, Y. Yamada and O. Sakurada: Effect of pH on Corrosion Resistance of Copper Tubes by Silicate and Ca Hardness in the Presence of Phosphonic Acid, Proceedings of the 69th Japan Conference on Materials and Environments, (2022) pp. 61–62 (in Japanese).
8. 8) T. Arima, Y. Yamaguchi, K. Sugiura, Y. Kano, T. Sasaki, I. Ikeda, T. Iyasu, Y. Yamada and O. Sakurada: Effect of Ca2+, SiO44− Concentrations and Carbon Film in Phosphonic Acid Solutions on Copper Tube Corrosion, J. Japan Inst. Copper 62 (2023) 114–118. doi:10.34562/jic.62.1_11410.34562/jic.62.1_114 ↗
9. 9) Y. Yamada, A. Mori, R. Hatanaka, T. Atsumi and N. Nakao: Pitting Corrosion of Copper Coiled Tubes in the Air Conditioning System having the Open Heat Storage Water Tank, Zairyo-to-Kankyo 47 (1998) 723–728. doi:10.3323/jcorr1991.47.72310.3323/jcorr1991.47.723 ↗