TIRF-Rheometer for Measuring Protein Adsorption under High Shear Rates: Constructional and Fluid Dynamic Aspects

H.P. Jennissen, A. Sanders, H.J. Schnittler, V. Hlady

Publisher page

Abstract

In total internal reflection fluorescence (TIRF) measurements an exponentially decaying evanescent wave of light (285–290 nm) excites the Trp residues in a protein to fluoresce at 350 nm when it is adsorbed to a transparent surface. A major problem in the measurement of protein adsorption kinetics in such systems is that the protein has to diffuse through a boundary layer to reach the surface. The thickness of such a boundary layer can be reduced by shearing the fluid phase. In the classical TIRF adsorption chamber only a unidirectional flow of buffer through the chamber is possible. In such a chamber the shear rates and shear stresses vary across the cross section and only low shear rates are obtainable. Therefore based on a rheological system for studying fluid shear stress on cultured cells a TIRF-chamber was constructed which allowed the installment of a rotating cone (max. rate: 1200 rpm) and plate viscometer-type variable shear device. In this case a flow field can be set up in which the shear rates and shear stresses are approximately constant. Cone angles (α) between 1.0–2.5 ° allowed shear rates (γ) between 0 and 7200 s−1. The TIRF-rheometer can be employed in two different modes in the form of: (a) a closed system (no fluid flow through the rheometer chamber), (b) an open system with continuous buffer flow through the chamber. The flow conditions were checked by observing the dissolution of a small spot of dried Coomassie blue as a function of the shear rate and time. A significant secondary flow was found with all cone angles and was dependent on the square root of the shear rate. Ink injection studies demonstrate that mixing times in the chamber below two seconds are obtainable. The TIRF Rheometer thus provides a means for studying the shear dependence of the adsorption of blood proteins and the generation of thin to ultra thin boundary layers for the measurement of protein adsorption kinetics relevant to biomaterials.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Blood properties and coagulation · Rheology and Fluid Dynamics Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.