Experimental investigation on cold-formed steel structural frame made with lipped channel column and beam elements subjected to lateral loading
Source abstract
Abstract
This study examines the structural performance of a cold-formed steel (CFS) structural frame subjected to lateral loading. An experimental investigation was conducted on cold-formed steel frame. Structural building frames made of cold-formed steel structural members. The structural members (beams and columns) were selected for building the structural frame on the basis of optimized design considering factors such as ease of availability of section and adequate testing conditions. In this way, the channel section is used for columns provided with and without lips. Parameters such as load-carrying capacity, stiffness, and the load– deflection relationship were examined. Based on the results and discussion, the structural frame made with a lipped channel section was found to have high load carrying capacity and high stiffness compared with the other models.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Annamalai University, India
References (14)
Show source-provided references
1. “Full-scale fire resistance tests of steel and plasterboard sheathed web-stiffened stud walls”10.1016/j.tws.2018.12.027 ↗
2. “Flexural behaviour of beams made of cold-formed steel sigma-shaped sections at ambient and fire conditions”10.1016/j.tws.2014.11.004 ↗
3. “Review on cold-formed steel connections”
4. “A comprehensive review on cold-formed steel building components”, In:
5. “Behaviour of cold-formed steel shear walls sheathed with high-capacity sheathing”10.1016/j.engstruct.2020.111280 ↗
6. “Recent research on cold-formed steel beams and columns subjected to elevated temperature: a review”10.1016/j.conbuildmat.2017.03.226 ↗
7. “Cold-formed steel member bending stiffness prediction”10.1016/j.jcsr.2015.07.004 ↗
8. “Review: development of performance-based fire design for cold-formed steel”10.1186/s40038-014-0001-3 ↗
9. “Axial capacity of CFS built-up columns comprising of lipped channels with spacers Nonlinear response and design”10.1016/j.engstruct.2020.110559 ↗
10. “Experimental investigation and finite element analysis of cold-formed steel channel columns with complex edge stiffeners”10.1016/j.tws.2020.106769 ↗
11. “Numerical and theoretical studies on cold-formed steel unlipped channels subjected to axial compression”
12. “Behavior of bolted cold-formed steel frame apex connections under a pure moment”10.1016/j.asej.2010.09.002 ↗
13. “Improved design rules on the buckling behavior of axially loaded back-to-back cold-formed steel built-up channel sections”
14. “Study on the behaviour of cold formed steel frames hollow”