Behavior of concrete cylinders confined by carbon-composite tapes and prestressed yarns 1. Experimental data
Source abstract
Abstract
The results of a comprehensive test program for the mechanical behavior of round concrete specimens confined by carbon-fiber epoxy tapes and prestressed carbon yarns are reported. Five different concrete batches of compressive strength from 20 to 100 MPa and the confinement of various thickness and pretension level were investigated. The specimens, which were subjected to monotonic or repeated compressive loadings, showed a nonlinear stress-strain behavior with a significant ductility and increased ultimate strength, in contrary to the brittle behavior of plain concrete. The limit of linearity on the stress-strain diagrams of the confined concrete roughly coincided with the ultimate strength of plain concrete. Above this limit, the damage accumulation and plastic deformations proceeded in the confined specimens. This fact was evidenced by the increasing slope of deformation diagrams in unloadings and repeated loadings and by the pronounced residual strains. The limit of linearity could be raised significantly by pretension of the carbon yarns during their winding.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. S. G. Lim and T. Hahn, “Composite materials in repairing and strengthening of civil engineering,” Korean Soc. Compos. Mater., 9, No. 4, 1–12 (1996).
2. M. Samaan, A. Mirmiram, and M. Shahawy, “Model of concrete confined by fiber composites,” ASCE J. Struct. Eng., 124, No. 9, 1025–1031 (1998).10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
3. S. Matthys, L. Taerwe, and K. Audenaert, “Tests on axially loaded concrete columns confined by fiber-reinforced polymer sheet wrapping,” in: 4th International Symposium on Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures (1999), pp. 217–228.
4. M. Saafi, H. A. Toutanji, and Z. Li, “Behavior of concrete columns confined with fiber-reinforced polymer tubes,” ACI Mater. J., 96, No. 4, 500–509 (1999).
5. L. De Lorenzis and R. Tepfers, “Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites,” ASCE J. Compos. Construct., 219–237 (August, 2003).10.1061/(ASCE)1090-0268(2003)7:3(219) ↗
6. Yu. G. Korobel’nikov, O. F. Siluyanov, V. P. Tamuzh, A. N. Shiryaev, I. L. Kumok, and M. T. Azarova, “Basic laws governing the mechanical properties of filler fibers in a unidirectional composite,” Mech. Compos. Mater., 23, No. 2, 194–198 (1987).10.1007/BF00606321 ↗
7. V. Tamuzs, C. S. You, and R. Tepfers, Experimental Investigation of CFRP-Confined Concretes under Compressive Load, Institute of Polymer Mechanics, University of Latvia, Aizkraukles 23, LV-1006, Riga, Latvia and Division of Building Technology, Chalmers University of Technology, S-412 96 Göteborg, Sweden (December, 2001), http://www.pmi.lv/Assets/Files/ CFRP-confined-concrete.pdf