Bond of FRP Reinforcement in Concrete - a Challenge
Source abstract
Abstract
The bond of ordinary steel reinforcement in concrete depends on many factors, such as the pullout resistance, the geometry of a concrete member, the placement of a bar in the member cross section, the cover splitting, the confinement caused by concrete and the surrounding reinforcement, the order of bond-crack appearance, and the bond-stress distribution along the bond length. The bond of FRP reinforcement depends on even a greater number of factors. Moreover, the types of FRP bars are numerous. Their surface is weaker than that of steel bars and may fracture by bond forces. The surface of FRP bars is softer and does not create as high local stress concentrations in bond contact points to concrete as the harder steel bars do. This fact often delays the appearance of cover splitting cracks along the bars. However, the load necessary for developing the crack pattern of ultimate splitting failure in concrete is then very dependent on whether the bar surface is glossy or rough. The FRP reinforcement can also be used for external shear and/or flexural strengthening of existing members. For this application, FRP bars are placed in grooves cut on the surface of the member to be strengthened and are fixed there with a cement mortar or epoxy paste. In such an application, the performance of bond between the FRP rod and the mortar or resin and then between the mortar or resin and concrete is critical for the effectiveness of the technique. The presence of two interfaces increases the number of parameters needed to characterize the global “joint” behavior and introduces new possible failure modes. The fundament for the bond resistance estimation should be an accepted bond philosophy linked to appropriate models. A system of bond tests should provide necessary coefficients for the models.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. V. Tamuzs, R. Apinis, J. Modniks, and R. Tepfers, “The performance of bond of FRP reinforcement in concrete,” SAMPE (Society for the Advancement of Material and Process Engineering) Symposium, May 6th-10th, Long Beach, California (2001), pp. 1738–1748.
2. Fib, Task Group “Bond Models,” “Bond of reinforcement in concrete,” Bulletin 10, Fédération internationale du béton, Case Postale 88, CH-1015 Lausanne, Switzerland (2000), pp. 313–394.
3. R. Tepfers, A Theory of Bond Applied to Overlapped Tensile Reinforcement Splices for Deformed Bars, Doctoral Thesis, Work No. 723, Publ. 73:2, Division of Concrete Structures, Chalmers University of Technology, Göteborg (May, 1973).
4. R. Tepfers, “Bond stress along lapped reinforcing bars,” Mag. Concrete Res., 32, No. 112, 135–142 (September, 1980).10.1680/macr.1980.32.112.135 ↗
5. R. Tepfers, “Lapped tensile reinforcement splices,” ASCE J. Struct. Div., 283–301 (January, 1982).10.1061/JSDEAG.0005865 ↗
6. R. Tepfers, I. Molander, and K. Thalenius, “Experience from testing of concrete reinforced with carbon fiber and aramid fiber strands,” in: XIV Nordic Concrete Congress & Nordic Concrete Industry Meeting, 6-8 August, Icelandic Concrete Association, Reykjavik (1992), pp. 337–347.
7. R. Tepfers, “Cracking of concrete cover along anchored deformed reinforcing bars,” Mag. Concrete Res., 31, No. 106, 3–12 (March, 1979).10.1680/macr.1979.31.106.3 ↗
8. R. Tepfers and P.-Å. Olsson, “Ring test for evaluation of bond properties of reinforcing bars,” in: Int. Conf. “Bond in Concrete — from Research to Practice,” October, Riga, Latvia (1992), pp. 1–89-1-99.
9. L. De Lorenzis, L. A. Rizzo, and A. La Tegola, “Bond and anchorage length of near-surface mounted frp rods in concrete,” in: Proc. ACIC2002, 14–17 April, Southampton, UK (2002).10.1680/apcfsaic.31227.0014 ↗
10. L. De Lorenzis and A. Nanni, “Bond between near-surface mounted fiber-reinforced polymer rods and concrete in structural strengthening,” ACI Struct. J., 99, No. 2, 123–132 (2002).
11. R. Tepfers and M. Karlsson, “Pull-out and tensile reinforcement splice tests using FRP C-BARs,” in: Proc. of the Third International Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures, FRPRCS-3, October, Japan Concrete Institute, Sapporo (1997), pp. 357–364.
12. R. Tepfers, G. Hedlund, and B. Rosinski, “Pull-out tensile reinforcement splice tests with GFRP bars,” in: Proc. of the ICCI'98, Second International Conference on Composites in Infrastructure, January 3-4, Tucson, Arizona. Vol. II (1998), pp. 37–51.
13. J. Magnusson, Bond and Anchorage of Deformed Bars in High-Strength Concrete, Chalmers University of Technology, Division of Concrete Structures, Licentiate Thesis, Work No. 1113, Publ. 97:1, Göteborg (November, 1997).
14. J. Magnusson, Bond an Anchorage of Ribbed Bars in High-Strength Concrete, Chalmers University of Technology, Division of Concrete Structures, Doctoral Thesis, Work No. 1113, Publ. 00:1, Göteborg (2000).