journal article·2011-07

Assessment of transmission of the shear stress in potted anchors for composite rods: 4. Nonlinear bond behavior between the FRP rod and the potting material

G. G. Portnov, C. E. Bakis, V. L. Kulakov

Mechanics of Composite Materials· Volume 47· Issue 3
Publisher page

Abstract

An analytical model for estimating the load-carrying capacity of cylindrical potted anchors with round rods made of high-strength composites is developed taking into account a partial debonding at the rod-pottant interface under tension loading. A detailed parametric analysis of the influence of propagation of the debonding on the load-carrying capacity of a potted anchor is carried out.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. G. G. Portnov, C. E. Bakis, and V. L. Kulakov, “Assessment of transmission of the shear stress in potted anchors for composite rods: 1. Sleeve of constant thickness,” Mech. Compos. Mater., 45, No. 3, 1–26 (2009).10.1007/s11029-009-9087-4 ↗
2. G. G. Portnov, C. E. Bakis, and V. L. Kulakov, “Assessment of transmission of the shear stress in potted anchors for composite rods: 2. Sleeve of variable thickness,” Mech. Compos. Mater., 45, No. 4, 381–398 (2009).10.1007/s11029-009-9099-0 ↗
3. G. G. Portnov, C. E. Bakis, and V. L. Kulakov, “Assessment of transmission of the shear stress in potted anchors for composite rods: 3. Bipotted Anchor,” Mech. Compos. Mater., 46, No. 2, 555–578 (2010).10.1007/s11029-010-9133-2 ↗
4. G. G. Portnov and C. E. Bakis, “Analysis of stress concentration during tension of round pultruded composite rods,” Compos. Struct., 83, No. 1, 100–109 (2008).10.1016/j.compstruct.2007.04.010 ↗
5. M. Keuser, B. Kepp, G. Mehlhorn, and F. Rostasy, “Nonlinear static analysis of end-fittings for GFRP-prestressing rods,” Comput. Struct., 17, Nos. 5–6, 719–730 (1983).10.1016/0045-7949(83)90086-X ↗
6. A. Al-Mayah, K. Soudki, and A. Plumtree, “Mechanical behavior of CFRP rod anchors under tensile loading,” J. Compos. Construct., 5, No. 2, 128–135 (2001).10.1061/(ASCE)1090-0268(2001)5:2(128) ↗
7. S. Yang, Z. Wu, X. Hu, and J. Zheng “Theoretical analysis on pullout of anchor from anchor–mortar–concrete anchorage system,” Eng. Fract. Mech., 75, 961–985 (2008).10.1016/j.engfracmech.2007.05.004 ↗
8. R. Tepfers and L. De Lorenzis, “Bond FRP reinforcement in concrete — a challenge,” Mech. Compos. Mater., 39, No. 4, 315–328 (2003).10.1023/A:1025642411103 ↗
9. C. E. Bakis, V. S. Uppuluri, A. Nanni, and T. E. Boothby, “Analysis of bonding mechanisms in smooth and lugged FRP rods embedded in concrete,” Compos. Sci. Technol., 58, No. 8, 1307–1319 (1998).10.1016/S0266-3538(98)00016-5 ↗
10. Federation Internationale du Beton (FIB). FRP Reinforcement in RC Structures, Bulletin No. 40, Lausanne, Switzerland (2007).
11. H. Diab and Zh. Wu, “A linear viscoelastic model for interfacial long-term behavior of FRP–concrete interface,” Composites. Part B: Engineering, 39, 722–730 (2008).10.1016/j.compositesb.2007.05.007 ↗
12. M. A. Aiello and M. Leone, “Interface analysis between FRP EBR system and concrete,” Composites. Part B: Engineering, 39, No. 4, 618–626 (2008).10.1016/j.compositesb.2007.07.002 ↗
13. K.-K. Choi, P. Meshgin, M. M. Reda Taha, “Shear creep of epoxy at the concrete–FRP interfaces,” Composites. Part B: Engineering, 38, Nos. 5–6, 772–780 (2007).10.1016/j.compositesb.2006.10.003 ↗
14. M. S. Mohamed Ali, D. J. Oehlers, M. C. Griffith, and R. Seracino, “Interfacial stress transfer of near surface-mounted FRP-to-concrete joints,” Eng. Struct., 30, No. 7, 1861–1868 (2008).10.1016/j.engstruct.2007.12.006 ↗
15. A. Mortazavi, “Anchorage and shear strength properties for composite tendons used in earthwork support systems,” Construct. Build. Mater., 21, No. 1, 109–117 (2007).10.1016/j.conbuildmat.2005.06.034 ↗
16. K. Cho, J.-R. Cho, W.-J.Chin, and B.-S. Kim, “Bond–slip model for coarse sand coated interface between FRP and concrete from optimization technique,” Comput. Struct., 84, No. 7, 439–449 (2006).10.1016/j.compstruc.2005.10.004 ↗
17. F. Focacci, A. Nanni, and C. E. Bakis, “Local bond–slip relationship for FRP reinforcement in concrete,” J. Compos. Construct., 4, No.1, 24–31 (2000).10.1061/(ASCE)1090-0268(2000)4:1(24) ↗
18. B. Zhang and B. Benmokrane, “Pullout bond properties of fiber-reinforced polymer tendons to grout,” J. Mater. Civil Eng., 14, No. 5, 399–408 (2002).10.1061/(ASCE)0899-1561(2002)14:5(399) ↗
19. X. Chang, G. Yue, H. Lin, and C. Tang “Modeling the pullout behavior of fiber reinforced polymer bars from concrete,” Construct. Build. Mater., 24, 431–437 (2010).10.1016/j.conbuildmat.2009.10.020 ↗
20. F. F. Ren, Z. J. Yang, J. F. Chen, and W. W. Chen. “An analytical analysis of full-range behavior of grouted rockbolts based on a tri-linear bond–slip model,” Construct. Build. Mater., 24, No. 3, 361–370 (2010).10.1016/j.conbuildmat.2009.08.021 ↗
21. B. Benmokrane, B. Zhang, and A. Chennouf, “Tensile properties and pullout behavior of AFRP and CFRP rods for grouted anchor applications,” Construct. Build. Mater., 14, Iss. 1, 157–170 (2000).10.1016/S0950-0618(00)00017-9 ↗
22. M. Baena, L. Torres, A. Turon, and C. Barris, “Experimental study of bond behavior between concrete and FRP bars using a pull-out test,” Composites. Part B, 40, No. 8, 784–797 (2009).10.1016/j.compositesb.2009.07.003 ↗