journal article·2020-09

Chiral constrained stent: Effect of structural design on the mechanical and intravascular stent deployment performances

Xiaoli Ruan, Weixing Yuan, Yiqun Hu, Jiejie Li, Wenwang Wu, Re Xia

Publisher page

Abstract

Abstract The high mortality of atherosclerosis-caused cardiovascular disease has promoted the requirement of designing novel intravascular stents with comprehensive robust mechanical performances, which is critical for re-constructing the blocked artery and recovering the biomechanical functions of artery vessels during vascular interventional therapy procedures. In this study, a chiral constrained structure with zero/negative Poisson's ratio and robust expansion transformation ability is proposed through combining the axial constraint effect of tetrachiral element and the good stretchability of oscillating wave element along circumferential direction. Afterwards, through applying the theoretical prediction, experimental tests and finite element analysis, the mechanical properties and stenting performances of the chiral constrained structure are explored. The modified tetrachiral topology shows strong orthotropic after integration of oscillating wave strut profile, indicating its capability of handling radial loads without great longitudinal recoil (foreshortening). Finally, stent deployment performances have been evaluated through a highly nonlinear coupling analysis of the stenosed vessels system, in terms of transformation characteristics, dogboning, radial recoil, foreshortening, and plaque prolapse ratio, etc. Especially, remarkable non-conventional performances of anti-dogboning and anti-foreshortening are identified in chiral constrained stent. Synthetically index is generated to compensate the competing behaviors among the above terms, and to improve the comprehensive mechanical performances of chiral constrained stent. These results show the potential in generating a new family of the intravascular stent with chiral mechanical metamaterials and provide a promising clinical application in curing atherosclerosis.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Elasticity and Material Modeling · Tribology and Lubrication Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (61)

Show source-provided references
1. Comparison of primary angioplasty with stent placement for treating symptomatic intracranial atherosclerotic diseases: a multicenter study10.1161/STROKEAHA.108.515361 ↗
2. Park · J. Am. Coll. Cardiol. · 2010 · 56 · 136610.1016/j.jacc.2010.03.097 ↗
3. Neurocognitive improvement after carotid artery stenting in patients with chronic internal carotid artery occlusion and cerebral ischemia10.1161/STROKEAHA.111.613133 ↗
4. Deployment of a self-expanding stent inside an artery: a finite element analysis10.1016/j.matdes.2012.05.019 ↗
5. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall10.1007/s10237-004-0039-6 ↗
6. Finite element simulation of stent and balloon interaction10.1016/S0924-0136(03)00435-7 ↗
7. Shape optimization of coronary artery stent based on a parametric model10.1016/j.finel.2009.01.001 ↗
8. In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy
9. Auxetic oesophageal stents: structure and mechanical properties10.1007/s10856-013-5067-2 ↗
10. Compliance and longitudinal strain of cardiovascular stents: influence of cell geometry10.1115/1.4005226 ↗
11. Mechanical properties of anti-tetrachiral auxetic stents10.1016/j.compstruct.2017.11.048 ↗
12. Layout design of a bi-stable cardiovascular stent using topology optimization10.1016/j.cma.2016.02.036 ↗
13. Comparative performance of uncoated, self-expanding metal biliary stents of different designs in 2 diameters: final results of an international multicenter, randomized, controlled trial10.1016/j.gie.2008.11.018 ↗
14. Stent deployment failure: reasons, implications, and short-and long-term outcomes
15. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial10.1161/01.CIR.103.23.2816 ↗
16. Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound10.1016/S0002-9149(02)02347-0 ↗
17. Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior10.1016/j.cad.2012.03.009 ↗
18. Multiobjective design optimisation of coronary stents10.1016/j.biomaterials.2011.07.059 ↗
19. Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts10.1007/s11517-018-1864-6 ↗
20. Tissue Stresses in Stented Coronary Arteries with Different Geometries: effect of the Relation Between Stent Length and Lesion Length10.1007/s40997-018-0206-5 ↗
21. The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: a review10.1016/j.actbio.2008.11.012 ↗
22. A platinum–chromium steel for cardiovascular stents10.1016/j.biomaterials.2010.01.146 ↗
23. A numerical study on the application of the functionally graded materials in the stent design10.1016/j.msec.2016.12.034 ↗
24. Deployment of a bulk metallic glass-based self-expandable stent in a patient-specific descending aorta10.1021/acsbiomaterials.6b00342 ↗
25. Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery—Finite element simulation10.1016/j.msec.2014.05.057 ↗
26. A computational approach for the lifetime prediction of cardiovascular balloon-expandable stents10.1016/j.ijfatigue.2015.02.002 ↗
27. Experimental studies and numerical analysis of the inflation and interaction of vascular balloon catheter-stent systems10.1007/s10439-008-9606-9 ↗
28. Virtual evaluation of stent graft deployment: a validated modeling and simulation study10.1016/j.jmbbm.2012.04.021 ↗
29. Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery10.1016/j.ijcard.2004.12.033 ↗
30. Comparing coronary stent material performance on a common geometric platform through simulated bench testing10.1016/j.jmbbm.2012.02.013 ↗
31. Concept Design of Cardiovascular Stents Based on Load Identification10.1007/s40032-014-0157-6 ↗
32. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations10.1016/j.jmbbm.2017.07.017 ↗
33. Computational comparison of the bending behavior of aortic stent-grafts10.1016/j.jmbbm.2011.09.006 ↗
34. Stent design affects femoropopliteal artery deformation10.1097/SLA.0000000000002747 ↗
35. Directions dependence of the elastic properties of a 3D augmented re-entrant cellular structure10.1016/j.matdes.2017.08.024 ↗
36. Mechanical metamaterials associated with stiffness, rigidity and compressibility: a brief review10.1016/j.pmatsci.2017.12.003 ↗
37. Additive manufacturing (3D printing): a review of materials, methods, applications and challenges10.1016/j.compositesb.2018.02.012 ↗
38. Properties of a chiral honeycomb with a Poisson's ratio of -110.1016/S0020-7403(96)00025-2 ↗
39. Elastic constants of 3-, 4-and 6-connected chiral and anti-chiral honeycombs subject to uniaxial in-plane loading10.1016/j.compscitech.2009.07.009 ↗
40. Mechanical properties of hierarchical anti-tetrachiral metastructures10.1016/j.eml.2017.08.004 ↗
41. Auxetic metamaterials and structures: a review10.1088/1361-665X/aaa61c ↗
42. Smart shape memory alloy chiral honeycomb10.1016/j.msea.2006.10.219 ↗
43. Metallic glass-based chiral nanolattice: light weight, auxeticity, and superior mechanical properties10.1016/j.mattod.2017.10.001 ↗
44. Homogenization of periodic hexa-and tetrachiral cellular solids10.1016/j.compstruct.2014.05.033 ↗
45. Chiral effect in plane isotropic micropolar elasticity and its application to chiral lattices10.1016/j.jmps.2012.06.008 ↗
46. Micropolar continuum modelling of bi-dimensional tetrachiral lattices
47. Mechanical design of antichiral-reentrant hybrid intravascular stent
48. A novel chiral three-dimensional material with negative Poisson's ratio and the equivalent elastic parameters10.1016/j.compstruct.2017.05.027 ↗
49. A survey of stent designs10.1080/136457002760273340 ↗
50. A novel bioresorbable polymer paclitaxel-eluting stent for the treatment of single and multivessel coronary disease: primary results of the COSTAR (Cobalt Chromium Stent With Antiproliferative for Restenosis) II study10.1016/j.jacc.2008.01.020 ↗
51. Effects of material on the deployment of coronary stents10.4028/www.scientific.net/AMR.123-125.315 ↗
52. Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery—Finite element simulation10.1016/j.msec.2014.05.057 ↗
53. Symplectic analysis of dynamic properties of hexagonal honeycomb sandwich tubes with plateau borders10.1016/j.jsv.2015.04.012 ↗
54. A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment10.1186/s40759-014-0002-x ↗
55. Three-dimensional mechanical metamaterials with a twist10.1126/science.aao4640 ↗
56. Chiral three-dimensional lattices with tunable Poisson's ratio10.1088/0964-1726/25/5/054005 ↗
57. Elastic properties of chiral, anti-chiral, and hierarchical honeycombs: a simple energy-based approach10.1016/j.taml.2016.02.004 ↗
58. On the properties of real finite‐sized planar and tubular stent‐like auxetic structures10.1002/pssb.201384257 ↗
59. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method10.1016/j.jmbbm.2017.08.023 ↗
60. Identification of hemodynamically optimal coronary stent designs based on vessel caliber10.1109/TBME.2012.2196275 ↗
61. Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry10.1016/j.medengphy.2008.11.002 ↗