Rapid and sensitive detection of formaldehyde based on AC electrokinetic effects
Source abstract
Abstract
Formaldehyde is a toxic water‐soluble organic matter. Its detection methods and detection limit have been attracting more attentions. An AC electrokinetic (ACEK)‐enhanced capacitive sensing method for rapid detection of trace formaldehyde in liquid is presented using commercial microelectrode chips. By this method, a detection limit is achieved as low as 0.01 ppm (μg/ml) within a 60 s response time. It is proved that the trace amount of formaldehyde in common solvents can also be effectively detected. As a complement, the capacitance change rate dependence on testing voltage and frequency is investigated. Compared to other existing detection methods, this ACEK‐based capacitive method is a low cost, high sensitive and fast detection means, which shows a great application prospect in industry and research such as food safety and specimen cleaning.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · Electrical and Bioimpedance Tomography · Electrostatics and Colloid Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electronics Science and Applied Physics Hefei University of Technology Hefei 230009 People's Republic of China
Department of Electrical Engineering and Computer Science The University of Tennessee Knoxville TN 37996 USA
Laboratory of Dielectric Functional Materials School of Physics & Material Science Anhui University Hefei 230601 People's Republic of China
Funding
National Natural Science Foundation of China
References (17)
Show source-provided references
1. 10.1016/j.aca.2007.03.04210.1016/j.aca.2007.03.042 ↗
2. 10.1016/j.matchemphys.2010.09.06910.1016/j.matchemphys.2010.09.069 ↗
3. 10.1016/j.snb.2013.02.04310.1016/j.snb.2013.02.043 ↗
4. 10.1016/j.snb.2015.11.12910.1016/j.snb.2015.11.129 ↗
5. 10.1016/j.bios.2013.08.01610.1016/j.bios.2013.08.016 ↗
6. 10.1039/c3an01112g10.1039/c3an01112g ↗
7. 10.1016/j.bios.2016.10.09810.1016/j.bios.2016.10.098 ↗
8. 10.1007/s00604‐015‐1556‐y10.1007/s00604‐015‐1556‐y ↗
9. CuiH.ChengC.WuJ.et al.: ‘Rapid detection of progesterone by commercially available microelectrode chips’.IEEE Sensors Conf. Baltimore USA 2013 pp.138–14010.1109/ICSENS.2013.6688157 ↗
10. 10.1002/elps.20140028410.1002/elps.201400284 ↗
11. 10.14737/journal.aavs/2015/3.6.347.35310.14737/journal.aavs/2015/3.6.347.353 ↗
12. WalewynsT.FrancisL.A.: ‘A novel MEMS tunable ionization sensor based on patterned freestanding Nickel nanowires and moving electrode’.IEEE TRANSDUCERS Conf. Beijing China 2011 pp.1986–198910.1109/TRANSDUCERS.2011.5969195 ↗
13. ThomasW.LaurentA.F.: ‘Modeling the sensing behavior of a MEMS field ionization device coupled with capacitive actuation’.IEEE Sensors Conf. Taipei Taiwan 2012 pp.1–410.1109/ICSENS.2012.6411421 ↗
14. 10.1007/s00216‐008‐2559‐x10.1007/s00216‐008‐2559‐x ↗
15. 10.1002/047171624310.1002/0471716243 ↗
16. Bard A.J. · 1980
17. 10.1021/ie049417u10.1021/ie049417u ↗