Generating usable electric power while sensing glucose
Source abstract
Abstract
Herein a system capable of simultaneously sensing glucose and harnessing sufficient energy to power a digital device is presented. This system is powered by an enzymatic glucose biofuel cell consisting of pyroloquinoline quinone glucose dehydrogenase‐modified bioanode and bilirubin oxidase‐modified biocathode. The electrical parameters from a single biofuel cell were amplified to 1.4 V using a charge pump circuit consisting of a capacitive element that senses glucose. Furthermore, a steady output DC supply of 3.2 V was obtained by interfacing a step‐up DC convertor circuit to the charge pump circuit. Such a system simultaneously senses glucose and harnesses energy in the presence of various glucose concentrations. The self‐powered glucose biosensor exhibited an improved sensitivity of 86.42 Hz/cm 2 mM with a linear range extending to 20 mM when operating a digital device simultaneously. This is a 3.7‐fold increase in sensor sensitivity when compared with previous self‐powered glucose biosensors. This novel self‐powered glucose biosensing system shows a promising future for powering implantable devices and assessing patient health.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Photoreceptor and optogenetics research · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Computer Science and Electrical Engineering University of Maryland Baltimore County and Bioelectronics Laboratory 1000 Hilltop Circle Baltimore MD 21250 USA
Funding
National Science Foundation
References (17)
Show source-provided references
1. 10.1016/j.bspc.2015.01.00510.1016/j.bspc.2015.01.005 ↗
2. 10.1016/j.rser.2016.09.04210.1016/j.rser.2016.09.042 ↗
3. 10.4172/2153‐0777.100011010.4172/2153‐0777.1000110 ↗
4. 10.1021/ja210794c10.1021/ja210794c ↗
5. 10.1039/C2EE23209J10.1039/C2EE23209J ↗
6. 10.1039/c3cp50929j10.1039/c3cp50929j ↗
7. 10.1016/j.bios.2015.11.02210.1016/j.bios.2015.11.022 ↗
8. Characterization of a self‐powered glucose monitor
9. Self‐powered glucose biosensor operating under physiological conditions
10. 10.1016/j.bios.2012.05.04110.1016/j.bios.2012.05.041 ↗
11. 10.1039/C5TA08823B10.1039/C5TA08823B ↗
12. 10.1021/acs.analchem.5b0294910.1021/acs.analchem.5b02949 ↗
13. 10.1021/acs.analchem.5b0001210.1021/acs.analchem.5b00012 ↗
14. 10.1002/elan.20150017310.1002/elan.201500173 ↗
15. 10.1016/j.bioelechem.2015.04.00910.1016/j.bioelechem.2015.04.009 ↗
16. 10.1016/j.jpowsour.2016.05.13310.1016/j.jpowsour.2016.05.133 ↗
17. 10.1039/C6RA06570H10.1039/C6RA06570H ↗