Interface Cleaning Strategy of Carbon Nanotube Field-Effect Transistor Biosensors for Ultrasensitive Detection of Ophthalmic Biomarkers
Source abstract
Abstract
Carbon nanotube (CNT) field-effect transistor (FET) biosensors combine the molecular recognition capabilities of bioreceptors with the signal amplification and transduction functions of nano-FET devices, enabling highly specific and ultrasensitive biomolecule detection. However, interface degradation and contamination introduced in the micronanofabrication process of batch manufacturing led to inhomogeneity in biofunctionalization of device and sensing performance, thus limiting the reproducible preparation and large-scale application of CNT FET biosensors. In this study, we proposed a comprehensive interface cleaning strategy using inductively coupled plasma oxygen (ICP-O 2 ) and ozone (O 3 ) treatment to reduce process contamination, which led to a 20% increase in transconductance, a 18.75% increase in carrier mobility, and near-theoretical-limit subthreshold swing (68 mV/dec) of CNT FET biosensors. Notably, the cleaning strategy facilitates the introduction of additional aptamer probe binding sites, thereby improving the sensitivity about 6.6-fold. We studied inflammatory related factors of ophthalmic diseases in clinical testing and found that our biosensors could detect trace level IL-6/IgE proteins in a complex tear matrix, with the limit of detection (LOD) reaching 1.37 aM and good consistency with the results of the enzyme-linked immunosorbent assay (ELISA). This study provides insights into the interface engineering of carbon-based FET biosensors and is expected to promote the practical application of CNT FET biosensors in the on-site detection of ophthalmic disease biomarkers.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Advanced biosensing and bioanalysis techniques · Mechanical and Optical Resonators
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hunan Institute of Advanced Sensing and Information Technology
Xiangtan University
Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-Based Electronics, School of Electronics
Peking University
Department of Ophthalmology
Beijing Chaoyang Hospital, Capital Medical University
Funding
National Key Research and Development Program of China · National Natural Science Foundation of China · Xiangtan University
References (50)
Show source-provided references
1. 10.18176/jiaci.096010.18176/jiaci.0960 ↗
2. 10.2147/OPTH.S17182210.2147/OPTH.S171822 ↗
3. 10.1038/sj.eye.670067510.1038/sj.eye.6700675 ↗
4. 10.1097/ICO.0b013e31803dcda210.1097/ICO.0b013e31803dcda2 ↗
5. 10.1007/s11306-020-1650-y10.1007/s11306-020-1650-y ↗
6. 10.3390/s1808265110.3390/s18082651 ↗
7. 10.1021/acsami.3c1239710.1021/acsami.3c12397 ↗
8. 10.1021/acsnano.4c0832310.1021/acsnano.4c08323 ↗
9. 10.1021/acsami.4c0563810.1021/acsami.4c05638 ↗
10. 10.1002/lpor.20240120910.1002/lpor.202401209 ↗
11. 10.1038/s41589-020-0591-010.1038/s41589-020-0591-0 ↗
12. 10.1021/acs.nanolett.4c0251810.1021/acs.nanolett.4c02518 ↗
13. 10.1016/j.sna.2025.11644110.1016/j.sna.2025.116441 ↗
14. 10.1021/acsnano.0c0352310.1021/acsnano.0c03523 ↗
15. 10.1002/adfm.20240490910.1002/adfm.202404909 ↗
16. 10.1007/s10825-020-01511-810.1007/s10825-020-01511-8 ↗
17. 10.1007/s00542-024-05760-610.1007/s00542-024-05760-6 ↗
18. 10.1021/acsnano.4c1405310.1021/acsnano.4c14053 ↗
19. 10.1016/j.mtnano.2024.10056510.1016/j.mtnano.2024.100565 ↗
20. 10.1021/acsnano.5c0052310.1021/acsnano.5c00523 ↗
21. 10.1002/adfm.20241691110.1002/adfm.202416911 ↗
22. 10.3390/s2017481110.3390/s20174811 ↗
23. 10.3390/coatings1303065310.3390/coatings13030653 ↗
24. 10.1021/acsnano.4c1737610.1021/acsnano.4c17376 ↗
25. 10.1016/j.carbon.2023.11813310.1016/j.carbon.2023.118133 ↗
26. 10.3390/nano1108212110.3390/nano11082121 ↗
27. 10.1038/s41928-017-0003-y10.1038/s41928-017-0003-y ↗
28. 10.1126/science.aba598010.1126/science.aba5980 ↗
29. 10.1038/s41467-021-27370-w10.1038/s41467-021-27370-w ↗
30. 10.1088/1361-6528/abac3110.1088/1361-6528/abac31 ↗
31. 10.1126/science.aan247610.1126/science.aan2476 ↗
32. 10.1126/science.aaj162810.1126/science.aaj1628 ↗
33. 10.1002/adma.20170706810.1002/adma.201707068 ↗
34. 10.1088/0256-307X/26/2/02730210.1088/0256-307X/26/2/027302 ↗
35. 10.1021/acsaelm.0c0095710.1021/acsaelm.0c00957 ↗
36. 10.1016/j.snb.2024.13683910.1016/j.snb.2024.136839 ↗
37. 10.1016/j.bios.2017.07.01010.1016/j.bios.2017.07.010 ↗
38. 10.3389/fmats.2020.58373910.3389/fmats.2020.583739 ↗
39. 10.3390/chemosensors1109048110.3390/chemosensors11090481 ↗
40. Belkind A. · Vacuum Technol. Coating · 2008 · 1
41. 10.1002/lpor.20220095010.1002/lpor.202200950 ↗
42. 10.1016/j.bios.2022.11495810.1016/j.bios.2022.114958 ↗
43. 10.1021/acsaelm.2c0168510.1021/acsaelm.2c01685 ↗
44. 10.1016/j.carbon.2023.11871810.1016/j.carbon.2023.118718 ↗
45. 10.1039/D1AN01244D10.1039/D1AN01244D ↗
46. 10.1021/acssensors.2c0096710.1021/acssensors.2c00967 ↗
47. 10.1021/acssensors.3c0069310.1021/acssensors.3c00693 ↗
48. 10.1111/bjd.1511410.1111/bjd.15114 ↗
49. 10.1016/j.bios.2019.03.05310.1016/j.bios.2019.03.053 ↗
50. 10.1021/acssensors.0c0075210.1021/acssensors.0c00752 ↗