AC electrokinetics based capture of yeast cells from ultra‐fast through‐flow for sensitive detection
Source abstract
Abstract
This work presents a three‐dimensional multi‐level microfluidic device that enables yeast cell trapping via alternating current (AC) electrokinetics (ACEK) from a rapid through‐flow of sample fluids. ACEK is a versatile technique to control and manipulate cells and microparticles at the micro/nano‐scale. Here the trapping device works by applying an AC signal over a pair of electrode across a flow‐through channel to capture bioparticles from an ultra‐fast through‐flow. The particle capture effect by ACEK was experimentally studied by measuring the cell densities at the inlet and outlet of the micro‐channel. Both symmetric AC signal and DC biased AC signal were used to achieve cell trapping. It is found that DC biased ACEK effect is highly capable of capturing cells from a rapid through‐flow. A trapping efficiency of 56.8% has been obtained from an ultra‐fast external flow with its average velocity at 4.44 mm/s. The merits of ACEK include low‐voltage electrical operation, which is suitable for portable lab‐on‐a‐chip systems. These devices offer numerous benefits for biological applications such as medical diagnostics, detection, drug screening, and particle trapping.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · Microfluidic and Capillary Electrophoresis Applications · Electrical and Bioimpedance Tomography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering and Computer Science The University of Tennessee Knoxville TN 37996 USA
Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47906 USA
Department of Electrical Engineering The University of Texas Rio Grande Valley Edinburg TX 78539 USA
References (29)
Show source-provided references
1. 10.1038/nrmicro161610.1038/nrmicro1616 ↗
2. 10.1039/c0lc00150c10.1039/c0lc00150c ↗
3. 10.1016/j.aca.2009.07.01710.1016/j.aca.2009.07.017 ↗
4. 10.1021/ac201115310.1021/ac2011153 ↗
5. 10.1109/TNANO.2005.85859210.1109/TNANO.2005.858592 ↗
6. 10.1049/iet‐nbt:2007002310.1049/iet‐nbt:20070023 ↗
7. 10.1006/jcis.1999.634610.1006/jcis.1999.6346 ↗
8. 10.1007/978-0-387-48998-8_610.1007/978-0-387-48998-8_6 ↗
9. 10.1021/ie049417u10.1021/ie049417u ↗
10. 10.1007/s10404‐006‐0138‐z10.1007/s10404‐006‐0138‐z ↗
11. 10.1007/s10404‐013‐1231‐810.1007/s10404‐013‐1231‐8 ↗
12. 10.1039/B408382M10.1039/B408382M ↗
13. 10.1007/s10544‐016‐0111‐x10.1007/s10544‐016‐0111‐x ↗
14. 10.1016/j.snb.2015.11.12910.1016/j.snb.2015.11.129 ↗
15. 10.1109/JSEN.2007.89736110.1109/JSEN.2007.897361 ↗
16. 10.1063/1.346744610.1063/1.3467446 ↗
17. 10.1073/pnas.070291610410.1073/pnas.0702916104 ↗
18. 10.2478/s11532‐011‐0008‐810.2478/s11532‐011‐0008‐8 ↗
19. 10.1007/BF0186969510.1007/BF01869695 ↗
20. 10.1016/0092‐8674(91)90042‐W10.1016/0092‐8674(91)90042‐W ↗
21. 10.1007/s10404‐009‐0433‐610.1007/s10404‐009‐0433‐6 ↗
22. 10.1063/1.274641310.1063/1.2746413 ↗
23. 10.1017/S002211200600159510.1017/S0022112006001595 ↗
24. 10.1049/iet‐nbt:2006002210.1049/iet‐nbt:20060022 ↗
25. WuJ.IslamN.LianM.: ‘High sensitivity particle detection by biased AC electro‐osmotic trapping on cantilever’.19th IEEE Int. Conf. on Micro Electro Mechanical System (MEMS) 22–26 January2006 pp.566–569
26. 10.1063/1.283262410.1063/1.2832624 ↗
27. 10.1063/1.308068110.1063/1.3080681 ↗
28. 10.1063/1.345662610.1063/1.3456626 ↗
29. 10.1016/j.snb.2016.12.12410.1016/j.snb.2016.12.124 ↗