Electrokinetic microchip‐based sample loading for surface plasmon resonance detection
Source abstract
Abstract
In this reported work, a microfluidic‐based fluid electrokinetic force has been used for surface plasmon resonance or surface plasmon resonance image (SPRI) detection. In this device, a modified rectangular microarray of Au instead of previous reported square or circular gold segments was designed and microfabricated with gold segment geometries and characterised by surface morphology studies. A voltage drop of maximal 400 V/cm was applied without gold erosion to drive fluorescein isothiocyanate isomer I in a high‐conductivity medium on the bare gold surface layer, enabling SPRI detection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · Microfluidic and Capillary Electrophoresis Applications · Electrowetting and Microfluidic Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Transducer Technology Institute of Electronics Chinese Academy of Sciences Beijing People's Republic of China
Funding
National Natural Science Foundation of China
References (26)
Show source-provided references
1. 10.1016/S0925-4005(98)00321-910.1016/S0925-4005(98)00321-9 ↗
2. 10.1155/2003/37291310.1155/2003/372913 ↗
3. 10.1016/j.aca.2011.11.01610.1016/j.aca.2011.11.016 ↗
4. 10.1016/j.copbio.2006.06.01210.1016/j.copbio.2006.06.012 ↗
5. 10.1016/j.bios.2010.09.03010.1016/j.bios.2010.09.030 ↗
6. 10.1016/0250-6874(83)85036-710.1016/0250-6874(83)85036-7 ↗
7. 10.1021/ac00020a02510.1021/ac00020a025 ↗
8. 10.1007/s10404-010-0638-810.1007/s10404-010-0638-8 ↗
9. 10.1038/nature0505810.1038/nature05058 ↗
10. 10.1039/b800606g10.1039/b800606g ↗
11. 10.1016/j.bios.2007.05.00710.1016/j.bios.2007.05.007 ↗
12. 10.1016/j.bios.2010.06.04110.1016/j.bios.2010.06.041 ↗
13. 10.3390/s12060709510.3390/s120607095 ↗
14. 10.4155/bio.12.410.4155/bio.12.4 ↗
15. 10.1016/j.ab.2006.08.00510.1016/j.ab.2006.08.005 ↗
16. 10.1039/b920589f10.1039/b920589f ↗
17. 10.1016/j.ab.2008.11.01410.1016/j.ab.2008.11.014 ↗
18. 10.1021/ac100316310.1021/ac1003163 ↗
19. 10.1039/c000705f10.1039/c000705f ↗
20. 10.1021/ac802668z10.1021/ac802668z ↗
21. 10.1021/ac06193210.1021/ac061932 ↗
22. 10.1016/j.bios.2008.11.03110.1016/j.bios.2008.11.031 ↗
23. CuiD.F.CaiH.Y.WangJ.B.et al.:Chinese Patent Appl. No. CN 200610066542.4 2006
24. 10.1016/j.corsci.2008.06.02110.1016/j.corsci.2008.06.021 ↗
25. 10.1016/0079-6816(96)00002-010.1016/0079-6816(96)00002-0 ↗
26. 10.1039/C1LC20605B10.1039/C1LC20605B ↗