Hollow Co 3 O 4 microspheres assembled with nanocrystals for non‐enzymatic glucose sensor
Source abstract
Abstract
A non‐enzymatic glucose sensor was developed by using the hollow Co 3 O 4 microspheres assembled with nanocrystals as the sensing materials. The hierarchical structured materials were prepared using carbon spheres as sacrificial templates. X‐ray diffraction, scanning electron microscope and transmission electron microscopy were employed to characterise the crystal structure and morphology of the hollow microspheres. The results showed that the as‐prepared cubic crystalline Co 3 O 4 products have a hollow nature, with the shell thicknesses of about 150 nm. The walls of the hollow microspheres were composed of lots of nanocrystals with diameters about 50 nm. The Co 3 O 4 hollow microspheres displayed superior electrochemical activity used as non‐enzymatic glucose sensors. The high linearity between catalytic current density and glucose concentration was obtained in the range of 2 μM–1.48 mM with a sensitivity of 68.77 μA mM −1 cm −2 . More importantly, the interference from the commonly interfering species such as L‐valine, urea, L‐proline, NaCl and L‐lysine can be effectively avoided. The high sensitivity, low detection limit and good selectivity indicated that the hollow Co 3 O 4 microsphere is a promising no‐enzymatic glucose sensor material for practical application.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advanced Nanomaterials in Catalysis · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Materials & Environmental Engineering Hangzhou Dianzi University Hangzhou 310018 People's Republic of China
References (32)
Show source-provided references
1. 10.1016/j.electacta.2014.11.02410.1016/j.electacta.2014.11.024 ↗
2. 10.1016/j.electacta.2013.10.15110.1016/j.electacta.2013.10.151 ↗
3. 10.1016/j.aca.2014.12.03010.1016/j.aca.2014.12.030 ↗
4. 10.1007/s00604‐015‐1493‐910.1007/s00604‐015‐1493‐9 ↗
5. 10.1016/j.bios.2007.11.00910.1016/j.bios.2007.11.009 ↗
6. 10.1002/elan.20130064510.1002/elan.201300645 ↗
7. 10.1016/j.jallcom.2013.12.18710.1016/j.jallcom.2013.12.187 ↗
8. 10.1016/j.snb.2015.01.02010.1016/j.snb.2015.01.020 ↗
9. 10.1016/j.electacta.2014.11.11510.1016/j.electacta.2014.11.115 ↗
10. 10.1016/j.snb.2014.12.04410.1016/j.snb.2014.12.044 ↗
11. 10.1039/C1CE05869J10.1039/C1CE05869J ↗
12. 10.1016/j.snb.2011.12.01210.1016/j.snb.2011.12.012 ↗
13. 10.1016/j.elecom.2011.01.02610.1016/j.elecom.2011.01.026 ↗
14. 10.1016/j.snb.2014.12.05010.1016/j.snb.2014.12.050 ↗
15. 10.1016/j.jallcom.2015.01.21310.1016/j.jallcom.2015.01.213 ↗
16. 10.1016/j.bios.2014.07.03110.1016/j.bios.2014.07.031 ↗
17. 10.1039/b914462e10.1039/b914462e ↗
18. 10.1016/j.snb.2014.06.12410.1016/j.snb.2014.06.124 ↗
19. 10.1021/nn506624g10.1021/nn506624g ↗
20. 10.1016/j.jpowsour.2014.08.06710.1016/j.jpowsour.2014.08.067 ↗
21. 10.1016/j.bios.2010.07.05010.1016/j.bios.2010.07.050 ↗
22. 10.1016/j.bios.2011.06.03310.1016/j.bios.2011.06.033 ↗
23. 10.1007/s12034‐014‐0084‐410.1007/s12034‐014‐0084‐4 ↗
24. 10.1016/j.matlet.2014.09.02110.1016/j.matlet.2014.09.021 ↗
25. 10.1039/C2RA20794J10.1039/C2RA20794J ↗
26. 10.1002/anie.20035238610.1002/anie.200352386 ↗
27. 10.1002/adfm.20130097610.1002/adfm.201300976 ↗
28. 10.1016/j.ssi.2010.06.02710.1016/j.ssi.2010.06.027 ↗
29. 10.1021/nn300097q10.1021/nn300097q ↗
30. Controllable growth of cobalt oxide nanoparticles on reduced graphene oxide and its application for highly sensitive glucose sensor10.1016/S1452-3981(23)10974-6 ↗
31. 10.1016/j.snb.2014.02.03410.1016/j.snb.2014.02.034 ↗
32. 10.1016/j.aca.2007.05.04710.1016/j.aca.2007.05.047 ↗