Threshold voltage adjustment of pMOS‐radiation field‐effect transistor with thick thermal oxide
Source abstract
Abstract
The pMOS‐RADFET (radiation field‐effect transistor) as a microdosimeter has been widely applied in spacecraft, medicine and personal dosimetry. Thick gate‐oxide and zero threshold voltage ( V th ) are two critical factors to achieve a high performance pMOS‐RADFET. In this reported work, threshold voltage adjustment techniques for a thick gate oxide RADFET by B + implantation are systematically simulated by Silvaco technology computer‐aided design, including implanting energy, implanting dose and annealing conditions. Impurity distributions in gate oxide and silicon substrate are analysed. The results show that the thicker the gate oxide is, the higher the implanting energy and larger dose for tuning V th to 0 V. Both the annealing temperature and the time have to be as low and as short as possible on the premise of sufficient ion activation.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advancements in Semiconductor Devices and Circuit Design · Radiation Effects in Electronics · CCD and CMOS Imaging Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Microelectronics Peking University Beijing 100871 People's Republic of China
Shenzhen Graduate School of Peking University Peking University Shenzhen People's Republic of China
References (10)
Show source-provided references
1. 10.1109/23.27751410.1109/23.277514 ↗
2. 10.1109/TNS.2004.83506510.1109/TNS.2004.835065 ↗
3. 10.1016/j.radmeas.2012.01.01710.1016/j.radmeas.2012.01.017 ↗
4. 10.1109/TNS.2009.201437610.1109/TNS.2009.2014376 ↗
5. JaksicA.RisticG.PejovicM.MohammadzadehA.LaneW.: ‘Characterisation of radiation response of 400 nm implanted gate oxide RADFETs.Proc. IEEE 2002 23rd Int. Conf. Microelectronics Niš Serbia 2002 vols. 1–2 pp.727–73010.1109/MIEL.2002.1003360 ↗
6. JaksicA.KimotoY.MohammadzadehA.MathewsonA.: ‘Dose rate dependence of RADFET irradiation and post‐irradiation responses’.Proc. 2004 24th Int. Conf. Microelectronics Niš Serbia 2004 vols. 1–2 pp.661–66410.1109/ICMEL.2004.1314915 ↗
7. O'ConnellB.EnrightA.ConneelyC.LaneW.: ‘Improving the sensitivity of PMOS dosimeters using dual dielectrics’.Proc. Fourth IEEE Euro. Conf. RADECS'97 Cannes France 1997 pp.282–28710.1109/RADECS.1997.698910 ↗
8. 10.1063/1.165351310.1063/1.1653513 ↗
9. 10.1063/1.171382510.1063/1.1713825 ↗
10. 10.1149/1.336076610.1149/1.3360766 ↗