Tilt sensor based on a dual‐axis microaccelerometer with maximum sensitivity and minimum uncertainty in the full measurement range
Source abstract
Abstract
This work presents an approach to enhance the sensitivity and lower the uncertainty of a tilt sensor based on a dual‐axis accelerometer. The arctangent function arctan( a 2 / a 1 ) instead of traditional arcsine function arcsin( a 2 /g ) or arcsin( a 1 / g ) is used to solve for tilt angle. As a result, the measured sensitivity of tilt angle is kept in the maximum constant value (17.45 mg/°) and the measurement uncertainty is kept in the minimum constant value (0.033° for the tilt sensor of this work) in the measurement range of −90° to +90°. It is also experimentally verified that the solving method has the maximum sensitivity (the average value of 17.74 mg/° with a root mean square of 0.008 mg/°) and minimum uncertainty (the average value of 0.034° with a root mean square of 0.003°) compared with other solving methods in the range of −90° to +90°]. The output of tilt sensor in the range of −90° to+90° and +90° to +270° is axial symmetry about 90°, so it is easy to extend the measurement range to 360°. Therefore, the presented approach is proved to be effective to enhance tilt sensor sensitivity and lower the uncertainty.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced MEMS and NEMS Technologies · Mechanical and Optical Resonators · Geophysics and Sensor Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
MOE Key Laboratory of Micro/Nano Systems for Aerospace Northwestern Polytechnical University Xi'an 710072 People's Republic of China
Funding
National Natural Science Foundation of China
References (15)
Show source-provided references
1. 10.1109/JMEMS.2014.235963310.1109/JMEMS.2014.2359633 ↗
2. ZhaoL.YeatmanE.M.: ‘Micro capacitive tilt sensor for human body movement detection’.Fourth Int. Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007) Aachen Germany March2007 pp.195–20010.1007/978-3-540-70994-7_34 ↗
3. 10.1109/JSEN.2014.236315710.1109/JSEN.2014.2363157 ↗
4. 10.1016/j.conengprac.2011.04.00210.1016/j.conengprac.2011.04.002 ↗
5. 10.1016/j.mechatronics.2011.11.01110.1016/j.mechatronics.2011.11.011 ↗
6. 10.1109/TIE.2009.201246910.1109/TIE.2009.2012469 ↗
7. An annular planar‐capacitive tilt sensor with a 360° measurement range
8. 10.1016/j.sna.2014.10.00410.1016/j.sna.2014.10.004 ↗
9. 10.1109/JMEMS.2011.216766210.1109/JMEMS.2011.2167662 ↗
10. LiB.ZhangH.ZhongJ.et al.: ‘A mode localization based resonant MEMS tilt sensor with a linear measurement range of 360°’.29th IEEE Int. Conf. Micro Electro Mechanical Systems (MEMS) Shanghai China January2016 pp.938–94110.1109/MEMSYS.2016.7421786 ↗
11. 10.1109/JMEMS.2015.251409210.1109/JMEMS.2015.2514092 ↗
12. WangS.RenJ.ZhangT.et al.: ‘A MEMS resonant tilt sensor with high sensitivity maintained in the whole 360° measurement range’.2016 IEEE SENSORS Orlando USA 2016 pp.1–310.1109/ICSENS.2016.7808792 ↗
13. LiE.ZhongJ.LiB.et al.: ‘A tilt sensor with a constant sensitivity output in the full measurement range’.12th IEEE Int. Conf. Nano/Micro Engineered and Molecular Systems (NEMS) Los Angeles USA April2017 pp.198–20110.1109/NEMS.2017.8017005 ↗
14. TaylorB.N.KuyattC.E.: ‘Guidelines for evaluating and expressing the uncertainty of NIST measurement results’ NIST Technical Note 199410.6028/NIST.TN.1297 ↗