Horizontal connection method for glass microfluidic devices
Source abstract
Abstract
In a conventional glass microfluidic system, the vertical connection is the most frequently used for connections between a microfluidic device and its peripheral equipment. However, it leads to a significant pressure drop at the inlet of a microfluidic device, decreases the flow velocity, and can introduce few samples than expected. To overcome these problems, a horizontal connection method for glass microfluidic devices, which have advantages such as keeping pressure/flow velocity, compatible with small space, reduced sample loss and convenience for modularisation is reported. These advantages are important for high‐speed analysis on precious samples such as single‐cell flow cytometry. In this work, they proposed a horizontal connection method which showed compatibility with high pressure (at least 0.6 MPa) at inlet without leakage, small loss of injected samples (<0.11%), and 22% faster flow velocity along the direction of applied pressure than that of vertical connection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrowetting and Microfluidic Technologies · Microfluidic and Capillary Electrophoresis Applications · Advanced Surface Polishing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Center for Biosystems Dynamics Research (BDR) RIKEN 1–3 Yamadaoka Suita Osaka 565‐0871 Japan
Division of Materials Science Nara Institute of Science and Technology Takayama Ikoma Nara 630‐0192 Japan
References (34)
Show source-provided references
1. 10.1088/0960‐1317/16/5/R0110.1088/0960‐1317/16/5/R01 ↗
2. 10.1039/C6LC00132G10.1039/C6LC00132G ↗
3. 10.1016/j.sna.2017.05.04710.1016/j.sna.2017.05.047 ↗
4. 10.1007/s10616‐011‐9415‐010.1007/s10616‐011‐9415‐0 ↗
5. 10.1016/j.snb.2018.11.02510.1016/j.snb.2018.11.025 ↗
6. 10.1016/j.sna.2019.11156610.1016/j.sna.2019.111566 ↗
7. 10.1039/c3an01266b10.1039/c3an01266b ↗
8. 10.1002/smll.20167015910.1002/smll.201670159 ↗
9. 10.1038/s41598‐017‐12378‐410.1038/s41598‐017‐12378‐4 ↗
10. 10.1073/pnas.120471810910.1073/pnas.1204718109 ↗
11. Effects of flow‐induced micro fluidic chip wall deformation on imaging flow cytometry
12. 10.1016/j.mee.2014.10.01310.1016/j.mee.2014.10.013 ↗
13. 10.1016/S1872‐2040(18)61126‐010.1016/S1872‐2040(18)61126‐0 ↗
14. 10.1016/j.cell.2018.08.02810.1016/j.cell.2018.08.028 ↗
15. 10.1038/s41698‐017‐0005‐210.1038/s41698‐017‐0005‐2 ↗
16. 10.1039/c3ra41218k10.1039/c3ra41218k ↗
17. 10.3390/mi705008310.3390/mi7050083 ↗
18. Lee H.B. · 2002 · 55
19. 10.1023/A:101857791051110.1023/A:1018577910511 ↗
20. 10.1039/C4LC01246A10.1039/C4LC01246A ↗
21. 10.1039/C7LC00396J10.1039/C7LC00396J ↗
22. 10.1002/cyto.a.2308410.1002/cyto.a.23084 ↗
23. 10.1364/OL.40.00480310.1364/OL.40.004803 ↗
24. 10.1063/1.494105010.1063/1.4941050 ↗
25. 10.1039/C8LC01370E10.1039/C8LC01370E ↗
26. 10.1016/j.bios.2017.07.05310.1016/j.bios.2017.07.053 ↗
27. 10.3390/mi708013910.3390/mi7080139 ↗
28. 10.1039/C7LC00951H10.1039/C7LC00951H ↗
29. 10.1038/s41598‐017‐17765‐510.1038/s41598‐017‐17765‐5 ↗
30. 10.1039/C5LC00094G10.1039/C5LC00094G ↗
31. 10.1039/C6LC00741D10.1039/C6LC00741D ↗
32. 10.1063/1.474291110.1063/1.4742911 ↗
33. 10.3390/mi805013710.3390/mi8050137 ↗
34. 10.1016/j.cej.2017.06.02810.1016/j.cej.2017.06.028 ↗