journal article·2018-08Open access

Non‐enzymatic continuous glucose monitoring system

Sean Moore, Byoung Hee You, Namwon Kim, Taehyun Park, In‐Hyouk Song

Micro & Nano Letters· Volume 13· Issue 8

Abstract

A prominent field of study in biosensor development is the study of electric properties which provide valuable insight into the fluids contents. In this research, a non‐enzymatic glucose sensor is fabricated, characterised, and employed. The developed device determines the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, and a real‐time measurement of glucose concentration. Deviations throughout the entire glucose range are detected as an inverse of the impedance in the cell due to the inverse relationship of glucose concentration and charge transfer resistance. The continuous monitoring of glucose is demonstrated by a rapid device response over two iterations of glucose concentration in ascending order: 50 µM, 400 µM, and 3.2 mM. At a sustained frequency of 10 kHz, the result shows a stable impedimetric response of 1038, 752, and 688 kΩ, respectively. The validity of the device as a continuous glucose monitoring method is carried out by repeating the cycle and observing the response.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Biosensors and Analytical Detection · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Engineering Technology Texas State University San Marcos 78666 USA

Ingram School of Engineering Texas State University San Marcos 78666 USA

School of Mechanical Engineering Kyungnam University Changwon‐si Gyeongsangnam‐do Republic of Korea

References (24)

Show source-provided references
1. 10.1016/j.bios.2015.08.00310.1016/j.bios.2015.08.003 ↗
2. 10.1016/S0956‐5663(01)00313‐X10.1016/S0956‐5663(01)00313‐X ↗
3. 10.1111/j.1749‐6632.1962.tb13623.x10.1111/j.1749‐6632.1962.tb13623.x ↗
4. 10.1016/j.bioelechem.2006.01.00310.1016/j.bioelechem.2006.01.003 ↗
5. 10.1016/j.aca.2005.05.08010.1016/j.aca.2005.05.080 ↗
6. 10.1016/j.snb.2015.08.01310.1016/j.snb.2015.08.013 ↗
7. 10.3390/s1701018210.3390/s17010182 ↗
8. 10.1007/BF0061080510.1007/BF00610805 ↗
9. A reinforced composite structure composed of polydiacetylene assemblies deposited on polystyrene microspheres and its application to H5n1 virus detection
10. 10.3390/s810615410.3390/s8106154 ↗
11. 10.1016/j.elecom.2006.11.03510.1016/j.elecom.2006.11.035 ↗
12. 10.1016/j.jelechem.2015.04.03310.1016/j.jelechem.2015.04.033 ↗
13. 10.1016/j.msec.2016.06.00610.1016/j.msec.2016.06.006 ↗
14. 10.1016/j.electacta.2013.09.04010.1016/j.electacta.2013.09.040 ↗
15. 10.1016/j.ab.2016.01.00610.1016/j.ab.2016.01.006 ↗
16. 10.3390/s10050485510.3390/s100504855 ↗
17. 10.1016/j.talanta.2005.04.05710.1016/j.talanta.2005.04.057 ↗
18. 10.1016/j.snb.2016.06.02010.1016/j.snb.2016.06.020 ↗
19. 10.1016/j.bios.2014.08.03910.1016/j.bios.2014.08.039 ↗
20. 10.1016/j.electacta.2016.08.04710.1016/j.electacta.2016.08.047 ↗
21. 10.1016/j.snb.2016.04.06510.1016/j.snb.2016.04.065 ↗
22. 10.1016/j.bios.2014.07.06110.1016/j.bios.2014.07.061 ↗
23. 10.1016/j.electacta.2010.04.06910.1016/j.electacta.2010.04.069 ↗
24. 10.1016/j.bios.2010.10.00910.1016/j.bios.2010.10.009 ↗