journal article·2003-12

Electron Beam Coater for Reduction of Charging in Ice-Embedded Biological Specimens using Ti88Si12 Alloy

Michael B. Sherman, Wah Chiu

Microscopy and Microanalysis· Volume 9· Issue 6
Publisher page

Abstract

Biological macromolecules embedded in vitreous ice are known to suffer from charging while being imaged in an electron transmission cryomicroscope. We developed an electron beam coater that deposits conductive films onto the surface of frozen-hydrated specimens. The conductive films help to dissipate charge during electron irradiation of poorly conductive ice-embedded biological samples. We observed significant reduction in charging of ice-embedded catalase crystals suspended over holes in a holey carbon film after coating them with a 30-Å-thick layer of an amorphous alloy, Ti88Si12. Images of the crystals after coating showed diffraction spots of up to 3 Å resolution.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Electron Microscopy Techniques and Applications · nanoparticles nucleation surface interactions · Nanowire Synthesis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. 10.1017/S003358350000429710.1017/S0033583500004297 ↗
2. Brink, J. , Sherman, M.B. , Berriman, J. , & Chiu, W. (1998b).Evaluation of charging on macromolecules in electron cryomicroscopy.Ultramicroscopy 72,41–52.10.1016/S0304-3991(97)00126-5 ↗
3. 10.1006/jsbi.1994.102910.1006/jsbi.1994.1029 ↗
4. Miyazawa, A. , Fujiyoshi, Y. , Stowell, M. , & Unwin, N. (1999).Nicotinic acetylcholine receptor at 4.6 A resolution: Transversetunnels in the channel wall.J Mol Biol 288,765–786.
5. 10.1007/978-1-4757-2519-310.1007/978-1-4757-2519-3 ↗
6. Henderson, R. (1992).Image contrast in high-resolution electron microscopy of biologicalmacromolecules: TMV in ice.Ultramicroscopy 46,1–18.
7. 10.1016/S0006-3495(96)79597-810.1016/S0006-3495(96)79597-8 ↗
8. Fukami, A. & Adachi, K. (1965).A new method of preparation of a self-perforated micro plastic gridand its application.J Elect Microsc 14,112–118.
9. 10.1016/0304-3991(89)90333-110.1016/0304-3991(89)90333-1 ↗
10. 10.1016/0304-3991(95)00010-X10.1016/0304-3991(95)00010-X ↗
11. 10.1111/j.1365-2818.1992.tb03251.x10.1111/j.1365-2818.1992.tb03251.x ↗
12. 10.1088/0950-7671/43/1/42610.1088/0950-7671/43/1/426 ↗
13. 10.1111/j.1365-2818.1984.tb02545.x10.1111/j.1365-2818.1984.tb02545.x ↗
14. Brink, J. , Gross, H. , Tittmann, P. , Sherman, M.B. , & Chiu, W. (1998a).Reduction of charging in protein electron cryomicroscopy.J Microsc 191,67–73.10.1046/j.1365-2818.1998.00342.x ↗
15. 10.1016/S0022-5320(68)80048-610.1016/S0022-5320(68)80048-6 ↗
16. 10.1016/0968-4328(96)00018-210.1016/0968-4328(96)00018-2 ↗