journal article·2016-06-22Open access

AirJump: Using Interfaces to Instantly Perform Simultaneous Extractions

Scott M. Berry, Hannah M. Pezzi, Alex J. LaVanway, David J. Guckenberger, Meghan A. Anderson, David J. Beebe

Abstract

Analyte isolation is an important process that spans a range of biomedical disciplines, including diagnostics, research, and forensics. While downstream analytical techniques have advanced in terms of both capability and throughput, analyte isolation technology has lagged behind, increasingly becoming the bottleneck in these processes. Thus, there exists a need for simple, fast, and easy to integrate analyte separation protocols to alleviate this bottleneck. Recently, a new class of technologies has emerged that leverages the movement of paramagnetic particle (PMP)-bound analytes through phase barriers to achieve a high efficiency separation in a single or a few steps. Specifically, the passage of a PMP/analyte aggregate through a phase interface (aqueous/air in this case) acts to efficiently "exclude" unbound (contaminant) material from PMP-bound analytes with higher efficiency than traditional washing-based solid-phase extraction (SPE) protocols (i.e., bind, wash several times, elute). Here, we describe for the first time a new type of "exclusion-based" sample preparation, which we term "AirJump". Upon realizing that much of the contaminant carryover stems from interactions with the sample vessel surface (e.g., pipetting residue, wetting), we aim to eliminate the influence of that factor. Thus, AirJump isolates PMP-bound analyte by "jumping" analyte directly out of a free liquid/air interface. Through careful characterization, we have demonstrated the validity of AirJump isolation through comparison to traditional washing-based isolations. Additionally, we have confirmed the suitability of AirJump in three important independent biological isolations, including protein immunoprecipitation, viral RNA isolation, and cell culture gene expression analysis. Taken together, these data sets demonstrate that AirJump performs efficiently, with high analyte yield, high purity, no cross contamination, rapid time-to-isolation, and excellent reproducibility.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Biosensors and Analytical Detection · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering, University of Wisconsin—Madison, Madison, Wisconsin 53705, United States

Funding

National Cancer Institute · Bill and Melinda Gates Foundation

References (28)

Show source-provided references
1. 10.2353/jmoldx.2010.09019010.2353/jmoldx.2010.090190 ↗
2. 10.1088/0960-1317/16/9/01710.1088/0960-1317/16/9/017 ↗
3. 10.1016/j.jbiosc.2009.07.00510.1016/j.jbiosc.2009.07.005 ↗
4. 10.1007/s10404-010-0692-210.1007/s10404-010-0692-2 ↗
5. 10.1021/am200400910.1021/am2004009 ↗
6. 10.1007/s10544-011-9573-z10.1007/s10544-011-9573-z ↗
7. 10.1039/c1lc00004g10.1039/c1lc00004g ↗
8. 10.1021/am506374t10.1021/am506374t ↗
9. 10.1039/C2LC40929A10.1039/C2LC40929A ↗
10. 10.1016/j.jmmm.2014.10.02010.1016/j.jmmm.2014.10.020 ↗
11. 10.1371/journal.pone.014952210.1371/journal.pone.0149522 ↗
12. 10.1063/1.493855910.1063/1.4938559 ↗
13. 10.1016/j.ab.2013.10.03810.1016/j.ab.2013.10.038 ↗
14. 10.1074/jbc.M112.36213710.1074/jbc.M112.362137 ↗
15. 10.1021/pr400225p10.1021/pr400225p ↗
16. 10.1021/ac402162r10.1021/ac402162r ↗
17. 10.1021/ac300085m10.1021/ac300085m ↗
18. 10.1016/j.jmoldx.2014.01.00410.1016/j.jmoldx.2014.01.004 ↗
19. 10.1177/221106821246202310.1177/2211068212462023 ↗
20. 10.1039/C0LC00296H10.1039/C0LC00296H ↗
21. 10.1021/ac500574t10.1021/ac500574t ↗
22. 10.1039/C2LC41136A10.1039/C2LC41136A ↗
23. 10.1039/b705045c10.1039/b705045c ↗
24. 10.1039/b819818g10.1039/b819818g ↗
25. 10.1016/j.pep.2010.12.01110.1016/j.pep.2010.12.011 ↗
26. 10.1038/nature0544810.1038/nature05448 ↗
27. 10.1097/QAI.0b013e3180640cf510.1097/QAI.0b013e3180640cf5 ↗
28. Abbott RealTime HIV-1 Product Insert. 2007.