Size-Resolved Single Entity Collision Biosensing for Dual Quantification of MicroRNAs in a Single Run
Source abstract
Abstract
Limited to the accuracy of size resolution, single entity collision biosensing (SECBS) for multiplex immunoassays remains challenging, because it is difficult to get the true value of nanoparticle (NP) sizes based on the current intensity due to the complex movement of NPs on the electrode surface. Considering that the size-dependent movement of NPs meanwhile will generate a characteristic current shape, in this work, the huge difference in the current rise time of 5 and 15 nm Pt NPs colliding on an Au ultramicroelectrode ( d = 30 μm) was originally used to develop a size-resolved SECBS for multiplex immunoassays of miRNAs. The limit concentration that can be detected was 0.5 fM. Compared with conventional electrochemical biosensors for multiplex immunoassays, for the size-resolved SECBS, one does not need to worry about potential overlapping. Therefore, the proposed method demonstrates a promising potential for the application of SECBS in multiplex immunoassays.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrochemical Analysis and Applications · Electrochemical Analysis and Applications · Electrochemical Analysis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
Funding
National Natural Science Foundation of China
References (46)
Show source-provided references
1. 10.1021/acs.analchem.9b0508010.1021/acs.analchem.9b05080 ↗
2. 10.1021/acs.chemrev.8b0025710.1021/acs.chemrev.8b00257 ↗
3. 10.1002/anie.20190196410.1002/anie.201901964 ↗
4. 10.1021/acs.analchem.9b0331710.1021/acs.analchem.9b03317 ↗
5. 10.1021/acs.analchem.8b0442410.1021/acs.analchem.8b04424 ↗
6. 10.1021/jacs.8b0942210.1021/jacs.8b09422 ↗
7. 10.1021/acs.analchem.8b0515310.1021/acs.analchem.8b05153 ↗
8. 10.1021/acsnano.7b0073310.1021/acsnano.7b00733 ↗
9. 10.1021/acs.analchem.8b0176010.1021/acs.analchem.8b01760 ↗
10. 10.1021/acssensors.8b0030510.1021/acssensors.8b00305 ↗
11. 10.1016/j.bios.2018.05.04810.1016/j.bios.2018.05.048 ↗
12. 10.1021/acs.analchem.8b0205510.1021/acs.analchem.8b02055 ↗
13. 10.1021/acs.analchem.9b0075010.1021/acs.analchem.9b00750 ↗
14. 10.1021/acs.analchem.8b0257210.1021/acs.analchem.8b02572 ↗
15. 10.1146/annurev.anchem.1.031207.11282610.1146/annurev.anchem.1.031207.112826 ↗
16. 10.1016/j.bios.2013.09.00910.1016/j.bios.2013.09.009 ↗
17. 10.1039/c1cc10240k10.1039/c1cc10240k ↗
18. 10.1016/j.biomaterials.2011.10.01210.1016/j.biomaterials.2011.10.012 ↗
19. 10.1021/ac200969w10.1021/ac200969w ↗
20. 10.1021/ja047857710.1021/ja0478577 ↗
21. 10.1021/ja310614x10.1021/ja310614x ↗
22. 10.1021/acs.analchem.5b0263910.1021/acs.analchem.5b02639 ↗
23. 10.1021/jacs.5b0862810.1021/jacs.5b08628 ↗
24. 10.1021/jacs.9b0451610.1021/jacs.9b04516 ↗
25. 10.1002/anie.20171245410.1002/anie.201712454 ↗
26. 10.1039/c2cp42940c10.1039/c2cp42940c ↗
27. 10.1021/ja304074f10.1021/ja304074f ↗
28. 10.1021/jacs.7b0364810.1021/jacs.7b03648 ↗
29. 10.1021/acs.analchem.9b0349210.1021/acs.analchem.9b03492 ↗
30. 10.1021/acscatal.6b0263310.1021/acscatal.6b02633 ↗
31. 10.1021/jacs.5b1314910.1021/jacs.5b13149 ↗
32. 10.1038/srep3002210.1038/srep30022 ↗
33. 10.1021/acs.langmuir.5b0312310.1021/acs.langmuir.5b03123 ↗
34. 10.1021/jacs.9b0941410.1021/jacs.9b09414 ↗
35. 10.1073/pnas.160500211310.1073/pnas.1605002113 ↗
36. 10.1073/pnas.150429411210.1073/pnas.1504294112 ↗
37. 10.1002/anie.20160531010.1002/anie.201605310 ↗
38. 10.1021/jacs.5b0454510.1021/jacs.5b04545 ↗
39. 10.1021/acs.analchem.8b0545710.1021/acs.analchem.8b05457 ↗
40. 10.1039/C9NR04566J10.1039/C9NR04566J ↗
41. 10.1039/C6SC04582K10.1039/C6SC04582K ↗
42. 10.1039/c0cp02543g10.1039/c0cp02543g ↗
43. 10.1002/ijch.20100001410.1002/ijch.201000014 ↗
44. 10.1021/ja072344w10.1021/ja072344w ↗
45. 10.1021/ja106054c10.1021/ja106054c ↗
46. 10.1007/s00216-003-1783-710.1007/s00216-003-1783-7 ↗