Fabrication of micro-gas chromatograph columns for fast chromatography
Source abstract
Abstract
Gas chromatography (GC) is one of the most widespread techniques used in laboratories as a way to separate and analyze complex mixtures of volatile and semi-volatile compounds. The main advantage of miniaturization of these systems is the increased performance due to the reduced time for analysis and reduced fabrication cost of the complex pneumatic flow system. In this paper advanced design ideas and fabrication processes to facilitate integration of the sample concentrator and the column will be presented. Using the LIGA process, 0.5- and 2-m-long, 50-μm-wide, and up to 600-μm-high aspect ratio metal GC separation columns with on-chip integrated sample injection and detection were fabricated. Initial experiments of coating these high aspect ratio columns show promising results when compared to simple tubular columns.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Analytical Chemistry and Chromatography · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Bhushan A, Yemane D, Goettert J, Overton EB, Murphy MC (2004a) Fabrication and testing of high aspect ratio metal micro-gas chromatograph columns. In: Proceedings of ASME international mechanical engineering congress & expo, Anaheim, 13–19 November 200410.1115/IMECE2004-62115 ↗
2. Bhushan A, Challa V, McKeon J, Yemane D, Overton EB, Murphy MC, Goettert J (2004b) Application of scanning acoustic microscopy in characterizing metal micro gas chromatograph columns. TMS Lett 1(7):145–146
3. Blumberg LM, Klee MS (2001) Quantitative comparison of performance of isothermal and temperature-programmed gas chromatography. J Chromatogr A 933(1–2):13–2610.1016/S0021-9673(01)01276-6 ↗
4. Golay JME (1981) The height equivalent to a theoretical plate or retentionless rectangular tubes. J Chromatogr A 216:1–810.1016/S0021-9673(00)82330-4 ↗
5. Grob RL (1995) Modern practice of gas chromatography. Wiley, New York
6. Ho CM, Tai YC (1998) Micro-electro-mechanical-systems (MEMS) and fluid flows. Annu Rev Fluid Mech 30:579–61210.1146/annurev.fluid.30.1.579 ↗
7. Hudson ML, Kottenstette R, Matzke CM, Frye-Mason GC, Shollenberger KA, Adkins DR, Wong CC (1998) Design, testing and simulation of microscale gas chromatography columns, vol. DSC-66. Proc ASME IMECE, pp 207–21410.1115/IMECE1998-1244 ↗
8. Kolesar ES, Reston RR (1996) Design and fabrication of the fundamental components integrated to realize a functional silicon micromachined gas chromatography system, vol. DSC-59. Proc ASME IMECE, pp 11–17
9. Lambertus G, Elstro A, Sensenig K, Potkay J, Agah M, Scheuering S, Wise K, Dorman K, Sacks R (2004) Design, fabrication and evaluation of microfabricated columns for gas chromatography. Anal Chem 76(9):2629–263710.1021/ac030367x ↗
10. Noh HS, Hesketh PJ, Frye-Mason GC (2002) Parylene gas chromatographic column for rapid thermal cycling. J Microelectromech Syst 11(6):718–72510.1109/JMEMS.2002.805052 ↗
11. Paegel LH, Simpson P, Mathies R (2000) Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels. Anal Chem 72(14):3030–303710.1021/ac000054r ↗
12. Spangler GE (1998) Height equivalent to a theoretical plate theory for rectangular GC columns. Anal Chem 70(22):4805–481610.1021/ac980328z ↗
13. Sumpter RS, Lee ML (1991) Enhanced radial dispersion in open tubular column chromatography. J Microcolumn Sep 3:91–11310.1002/mcs.1220030203 ↗
14. Terry SC, Herman JC (1979) A gas chromatographic air analyzer fabricated on a silicon wafer. IEEE Trans Electron Devices 26:1880–188610.1109/T-ED.1979.19791 ↗
15. Whiting JJ, Lu CJ, Zellers ET, Sacks RD (2001) A portable, high-speed, vacuum-outlet GC vapor analyzer employing air as carrier gas and surface acoustic wave detection. Anal Chem 73(19):4668–467510.1021/ac0103726 ↗