Fully coupled modeling and design of a piezoelectric actuation based valveless micropump for drug delivery application
Source abstract
Abstract
The precise control over the drug delivery involved in several vital applications including healthcare is required for achieving a therapeutic effect. For such precise control/manipulation of the drugs, micropumps are used. These micropumps are basically of two types viz. check valve-based and valveless micropumps. The valveless micropumps are preferable due to the congestion-free operation of diffuser/nozzle valves. In this paper, design optimization of a valveless piezo-electric actuation based micropump is carried out using COMSOL Multiphysics 5.0 by coupling two Multiphysics interface modules namely fluid–structure interaction and piezoelectric physics modules. Using simulation studies, the influence of pump design parameters including diffuser angle, diffuser length, neck width, chamber depth, chamber diameter and diaphragm thickness on net flow rate is studied. An optimal set of design parameters for the proposed micropump is identified. Further, the influence of actuation frequency on the flow rate is analysed. It is found that the proposed micropump is capable to deliver a net flow rate of 20 µl/min and a maximum back pressure attainable is 200 Pa.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Amirouche F, Zhou Y, Johnson T (2009) Current micropump technologies and their biomedical applications. Microsyst Technol 15(5):647–66610.1007/s00542-009-0804-7 ↗
2. Chen YT, Kang SW, Chang PF (2003) A manufacturing technique for 3D polymer micro-venturi tube. Int J Mach Tools Manuf 43(4):421–42410.1016/S0890-6955(02)00262-6 ↗
3. Chen YT, Kang SW, Wu LC, Lee SH (2008) Fabrication and investigation of PDMS micro-diffuser/nozzle. J Mater Process Technol 198(1–3):478–48410.1016/j.jmatprotec.2007.07.025 ↗
4. Cui Q, Liu C, Zha XF (2008) Simulation and optimization of a piezoelectric micropump for medical applications. In J Adv Manufact Technol 36(5–6):516–52410.1007/s00170-006-0867-x ↗
5. Dau VT, Dinh TX, Katsuhiko T, Susumu S (2009) A cross-junction channel valveless-micropump with PZT actuation. Microsyst Technol 15(7):1039–104410.1007/s00542-009-0878-2 ↗
6. de Lima CR, Vatanabe SL, Choi A, Nakasone PH, Pires RF, Silva ECN (2009) A biomimetic piezoelectric pump: computational and experimental characterization. Sens Actuators A 152(1):110–11810.1016/j.sna.2009.02.038 ↗
7. Fan B, Song G, Hussain F (2005) Simulation of a piezoelectrically actuated valveless micropump. Smart Mater Struct 14(2):40010.1088/0964-1726/14/2/014 ↗
8. Gidde RR, Pawar PM (2017) On effect of viscoelastic characteristics of polymers on performance of micropump. Adv Mech Eng 9(2):168781401769121110.1177/1687814017691211 ↗
9. Gidde RR, Pawar PM, Ronge BP, Dhamgaye VP (2019) Design optimization of an electromagnetic actuation based valveless micropump for drug delivery application. Microsyst Technol 25(2):509–51910.1007/s00542-018-3987-y ↗
10. Guo L, Yan W, Xu Y, Chen Y (2012) Valveless piezoelectric micropump of parallel double chambers. In J Precis Eng Manuf 13(5):771–77610.1007/s12541-012-0101-8 ↗
11. Kanda K, Moriue S, Fujita T, Maenaka K (2017) Three-dimensional piezoelectric MEMS actuator by using sputtering deposition of Pb (Zr, Ti) O3 on microstructure sidewalls. Smart Mater Struct 26(4):04501910.1088/1361-665X/aa61eb ↗
12. Laser DJ, Santiago JG (2004) A review of micropumps. J Micromech Microeng 14(6):R3510.1088/0960-1317/14/6/R01 ↗
13. Liu Y, Komatsuzaki H, Imai S, Nishioka Y (2011) Planar diffuser/nozzle micropumps with extremely thin polyimide diaphragms. Sens Actuators A 169(2):259–26510.1016/j.sna.2011.02.009 ↗
14. Mo C, Wright R, Slaughter WS, Clark WW (2006) Behaviour of a unimorph circular piezoelectric actuator. Smart Mater Struct 15(4):109410.1088/0964-1726/15/4/023 ↗
15. Mohith S, Karanth PN, Kulkarni SM (2018) Recent trends in mechanical micropumps and their applications: a review. Mechatronics 60:34–5510.1016/j.mechatronics.2019.04.009 ↗
16. Nguyen NT, Truong TQ (2004) A fully polymeric micropump with piezoelectric actuator. Sens Actuators B Chem 97(1):137–14310.1016/S0925-4005(03)00521-5 ↗
17. Nguyen NT, Wereley S (2006) Fundamentals and applications of microfluidics. Artech house, pp 293–341
18. Nisar A, Afzulpurkar N, Mahaisavariya B, Tuantranont A (2008) MEMS-based micropumps in drug delivery and biomedical applications. Sens Actuators B Chem 130(2):917–94210.1016/j.snb.2007.10.064 ↗
19. Olsson A, Stemme G, Stemme E (1995) A valve-less planar fluid pump with two pump chambers. Sens Actuators A 47(1–3):549–55610.1016/0924-4247(94)00960-P ↗
20. Pan QS, He LG, Huang FS, Wang XY, Feng ZH (2015) Piezoelectric micropump using dual-frequency drive. Sens Actuators A 229:86–9310.1016/j.sna.2015.03.029 ↗
21. Park JH, Seo MY, Ham YB, Yun SN, Kim DI (2013) A study on high-output piezoelectric micropumps for application in DMFC. J Electroceram 30(1–2):102–10710.1007/s10832-012-9740-5 ↗
22. Pawar PM, Gidde RR, Ronge BP (2016) Shape optimization of microfluidic pump using fluid-structure interaction approach. In: techno-societal 2016, international conference on advanced technologies for societal applications. Springer, Cham, pp 471–477
23. Revathi S, Padmanabhan R (2016) Study of the effect on flow rate for planar type polymer-based diaphragm piezoelectric actuated valveless micropump for insulin delivery. Adv Mater Proc Technol 2(1):31–43
24. Revathi S, Padmanabhan R (2018) Design and Development of piezoelectric composite-based micropump. J Microelectromech Syst 27(6):1105–111310.1109/JMEMS.2018.2870949 ↗
25. Sassa F, Al-Zain Y, Ginoza T, Miyazaki S, Suzuki H (2012) Miniaturized shape memory alloy pumps for stepping microfluidic transport. Sens Actuators B Chem 165(1):157–16310.1016/j.snb.2011.12.085 ↗
26. Sen AK, Darabi J, Knapp DR (2007) Simulation and parametric study of a novel multi-spray emitter for ESI–MS applications. Microfluid Nanofluid 3(3):283–29810.1007/s10404-006-0122-7 ↗
27. Singh S, Kumar N, George D, Sen AK (2015) Analytical modeling, simulations and experimental studies of a PZT actuated planar valveless PDMS micropump. Sens Actuator A Phys 225:81–9410.1016/j.sna.2015.02.012 ↗
28. Singhal V, Garimella SV, Murthy JY (2004) Low Reynolds number flow through nozzle-diffuser elements in valveless micropumps. Sens Actuator A Phys 113(2):226–23510.1016/j.sna.2004.03.002 ↗
29. Stemme E, Stemme G (1993) A valveless diffuser/nozzle-based fluid pump. Sen Actuator A Phys 39(2):159–16710.1016/0924-4247(93)80213-Z ↗
30. Wang YN, Fu LM (2018) Micropumps and biomedical applications—a review. Microelectron Eng 195:121–13810.1016/j.mee.2018.04.008 ↗
31. Xia GD, Li YF, Wang J, Zhai YL (2016) Numerical and experimental analyses of planar micromixer with gaps and baffles based on field synergy principle. Int Commun Heat Mass Transf 71:188–19610.1016/j.icheatmasstransfer.2015.12.029 ↗
32. Yamahata C, Lotto C, Al-Assaf E, Gijs MAM (2005) A PMMA valveless micropump using electromagnetic actuation. Microfluid Nanofluid 1(3):197–20710.1007/s10404-004-0007-6 ↗
33. Yang KS, Chao TF, Chen IY, Wang CC, Shyu JC (2012) A comparative study of nozzle/diffuser micropumps with novel valves. Molecules 17(2):2178–218710.3390/molecules17022178 ↗
34. Zhang Z, Kan J, Cheng G, Wang H, Jiang Y (2013) A piezoelectric micropump with an integrated sensor based on space-division multiplexing. Sens Actuators A Phys 203:29–3610.1016/j.sna.2013.08.027 ↗
35. Zhou Y, Amirouche F (2009) Study of fluid damping effects on resonant frequency of an electromagnetically actuated valveless micropump. Int J Adv Manuf Technol 45(11–12):118710.1007/s00170-009-2053-4 ↗
36. Zhou Y, Amirouche F (2011) An electromagnetically-actuated all-PDMS valveless micropump for drug delivery. Micromachines 2(3):345–35510.3390/mi2030345 ↗