Comparison of in-plane and out-of-plane piezoelectric microresonators for real-time monitoring of engine oil contamination with diesel
Source abstract
Abstract
Real-time monitoring of the physical properties of liquids, such as lubricants, is a very important issue for the automotive industry. For example, contamination of lubricating oil by diesel soot has a significant impact on engine wear. Resonant microstructures are regarded as a precise and compact solution for tracking the viscosity and density of lubricant oils. In this work, we report two different resonators for the monitoring of oil dilution with diesel fuel; one device was designed to vibrate in out-of-plane modes (12-mode or 14-mode), while the other micro-plate was actuated in the first extensional in-plane mode. To determine from the measurements the resonance parameters of interest (resonance frequency and quality factor), an interface circuit was implemented and included within a closed-loop scheme. Two types of oscillator circuits were tested, a Phase-Locked Loop based on instrumentation and a more compact version based on discrete electronics, showing similar resolution. A model with fitting parameters was validated allowing for the determination of the viscosity and density of the fluids under test, for which only a small amount of test liquid, in the range of 0.5 ml, was required. Our results demonstrate the performance of the resonators in oils with viscosity up to 90 mPa s. For such viscosity, the quality factor measured at 25 °C was 7 for the 12-mode, 19 for the 14-mode and 16 for the extensional mode. The best resolution for both fluid material parameters was obtained in the 14-mode, showing 3.92 × 10ź5 g/ml for the density and 1.27 × 10ź1 mPa s for the viscosity, in pure lubricant oil SAE 0W30. Finally, the resonator with the best result (14-mode) was also tested in continuous-flow measurements, showing a resolution of 0.5 ppm of diesel contamination in a pure lubricant oil SAE 2.5 W.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Acoustic Wave Resonator Technologies · Mechanical and Optical Resonators · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Agoston A, Ötsch C, Jakoby B (2005) Viscosity sensors for engine oil condition monitoring—Application and interpretation of results. Sens Actuators A Phys 121:327–332. doi: 10.1016/j.sna.2005.02.02410.1016/j.sna.2005.02.024 ↗
2. Aldajah S, Ajayi OO, Fenske GR, Goldblatt IL (2007) Effect of exhaust gas recirculation (EGR) contamination of diesel engine oil on wear. Wear 263:93–98. doi: 10.1016/j.wear.2006.12.05510.1016/j.wear.2006.12.055 ↗
3. Dufour I, Lemaire E, Caillard B et al. (2014) Effect of hydrodynamic force on microcantilever vibrations: applications to liquid-phase chemical sensing. Sens Actuators B: Chem 192:664–672. doi: 10.1016/j.snb.2013.10.10610.1016/j.snb.2013.10.106 ↗
4. Gatti PL, Ferrari V (2001) Applied structural and mechanical vibrations. doi: 10.1016/S0141-0296(00)00050-X10.1016/S0141-0296(00)00050-X ↗
5. George S, Balla S, Gautam M (2007) Effect of diesel soot contaminated oil on engine wear. Wear 262:1113–1122. doi: 10.1016/j.wear.2006.11.00210.1016/j.wear.2006.11.002 ↗
6. Heinisch M, Voglhuber-Brunnmaier T, Reichel EK et al (2014) Reduced order models for resonant viscosity and mass density sensors. Sens Actuators A Phys 220:76–84. doi: 10.1016/j.sna.2014.09.00610.1016/j.sna.2014.09.006 ↗
7. Ho GK, Abdolvand R, Sivapurapu A et al (2008) Piezoelectric-on-silicon lateral bulk acoustic wave micromechanical resonators. J Microelectromechanical Syst 17:512–520. doi: 10.1109/JMEMS.2007.90675810.1109/JMEMS.2007.906758 ↗
8. Ivaldi P, Abergel J, Matheny MH et al (2011) 50 nm thick AlN film-based piezoelectric cantilevers for gravimetric detection. J Micromechanics Microengineering 21:085023. doi: 10.1088/0960-1317/21/8/08502310.1088/0960-1317/21/8/085023 ↗
9. Jakoby B, Member S, Vellekoop MJ (2011) Physical sensors for liquid properties. IEEE Sens J 11:3076–308510.1109/JSEN.2011.2167716 ↗
10. Kucera M, Wistrela E, Pfusterschmied G et al (2014) Characterization of a roof tile-shaped out-of-plane vibrational mode in aluminum-nitride-actuated self-sensing micro-resonators for liquid monitoring purposes. Appl Phys Lett 104:10–15. doi: 10.1063/1.488217710.1063/1.4882177 ↗
11. Lapuerta M, Hernández JJ, Oliva F (2014) Strategies for active diesel particulate filter regeneration based on late injection and exhaust recirculation with different fuels. Int J Engine Res 15:209–221. doi: 10.1177/146808741246858410.1177/1468087412468584 ↗
12. Manzaneque T, Ruiz V, Hernando-García J et al (2012) Characterization and simulation of the first extensional mode of rectangular micro-plates in liquid media. Appl Phys Lett 101:151904. doi: 10.1063/1.475847010.1063/1.4758470 ↗
13. Manzaneque T, Ruiz-Díez V, Hernando-García J et al (2014) Piezoelectric MEMS resonator-based oscillator for density and viscosity sensing. Sens Actuators A Phys. doi: 10.1016/j.sna.2014.10.00210.1016/j.sna.2014.10.002 ↗
14. Milpied J, Uhrich M, Patissier B, Bernasconi L (2010) Applications of tuning fork resonators for engine oil, fuel, biodiesel fuel and urea quality monitoring. SAE Int J Fuels Lubr 2(2):45–53. doi: 10.4271/2009-01-263910.4271/2009-01-2639 ↗
15. Park KKK, Lee HJ, Yaralioglu GG et al (2007) Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen. Appl Phys Lett 91:094102. doi: 10.1063/1.277634810.1063/1.2776348 ↗
16. Pettine J, Patrascu M, Karabacak DM et al (2013) Volatile detection system using piezoelectric micromechanical resonators interfaced by an oscillator readout. Sens Actuators A Phys 189:496–503. doi: 10.1016/j.sna.2012.11.00310.1016/j.sna.2012.11.003 ↗
17. Seo JH, Brand O (2008) High Q-factor in-plane-mode resonant microsensor platform for gaseous/liquid environment. J Microelectromechanical Syst 17:483–493. doi: 10.1109/JMEMS.2008.91632810.1109/JMEMS.2008.916328 ↗
18. Toledo J, Manzaneque T, Hernando-García J et al (2014) Application of quartz tuning forks and extensional microresonators for viscosity and density measurements in oil/fuel mixtures. Microsyst Technol 20:945–953. doi: 10.1007/s00542-014-2095-x10.1007/s00542-014-2095-x ↗
19. Van Eysden CA, Sader JE (2009) Frequency response of cantilever beams immersed in compressible fluids with applications to the atomic force microscope. J Appl Phys 106:094904. doi: 10.1063/1.325419110.1063/1.3254191 ↗
20. van Mullem C, Tilmans H (1992) Electrical cross-talk in two-port resonators—the resonant silicon beam force sensor. Sensors Actuators A Phys 31:168–173. doi: 10.1016/0924-4247(92)80099-O10.1016/0924-4247(92)80099-O ↗
21. von Neumann J, Kent RH, Bellinson HR, Hart BI (1941) The mean square successive difference. Ann Math Stat 12:153–162. doi: 10.1214/aoms/117773174610.1214/aoms/1177731746 ↗
22. Walls FL, Allan DW (1986) Measurements of frequency stability. Proc IEEE 74:162–168. doi: 10.1109/PROC.1986.1342910.1109/PROC.1986.13429 ↗
23. Wilson TL, Campbell GA, Mutharasan R (2007) Viscosity and density values from excitation level response of piezoelectric-excited cantilever sensors. Sens Actuators A Phys 138:44–51. doi: 10.1016/j.sna.2007.04.05010.1016/j.sna.2007.04.050 ↗