Lock-in amplifier powered analogue Q-control circuit for self-actuated self-sensing piezoelectric MEMS resonators
Source abstract
Abstract
This paper presents a novel analogue Q-control circuit. A self-actuated and self-sensing piezoelectric microstructure in combination with a lock-in amplifier is used to provide a feedback signal with a substantially reduced noise level. This DC-value being proportional to the piezoelectric current is multiplied with a carrier sinusoidal signal on a custom-designed analogue printed circuit board applying an analogue amplifier IC. With this generated analogue feedback signal a complete analogue Q-control circuit is realized enabling faster response and as a consequence measurement cycles are less time consuming. Using this proposed Q-control technique, the Q-factor is increased from 397 to about 8,537 in air without pushing the feedback loop circuitry to stability limits. We believe that these promising results will stimulate further activities for a reliable on-line monitoring of even highly viscous liquids in the near future.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical and Optical Resonators · Advanced MEMS and NEMS Technologies · Acoustic Wave Resonator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Abadal G, Davis ZJ, Helbo B, Borrisé X, Ruiz R, Boisen A, Campabadal F, Esteve J, Figueras E, Pérez-Murano F, Barniol N (2001) Electromechanical model of a resonating nano-cantilever-based sensor for high-resolution and high-sensitivity mass detection. Nanotechnology 12:10010.1088/0957-4484/12/2/305 ↗
2. Beardslee LA, Addous AM, Heinrich S, Josse F, Dufour I, Brand O (2010) Thermal excitation and piezoelectric detection of cantilever in-plane resonance modes for sensing applications. J Microelectromech Syst 19:101510.1109/JMEMS.2010.2052093 ↗
3. Ekinci KL, Yang YT, Roukes ML (2004) Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems. J Appl Phys 95:2682–268910.1063/1.1642738 ↗
4. Graeme JG (1996) Photodiode amplifiers: op amp solutions. McGraw-Hill, Boston
5. Ikehara T, Lu J, Konno M, Maeda R, Mihara T (2007) A high quality-factor silicon cantilever for a low detection-limit resonant mass sensor operated in air. J Micromech Microeng 17:249110.1088/0960-1317/17/12/015 ↗
6. Johnson BN, Mutharasan R (2012) Biosensing using dynamic-mode cantilever sensors: a review. Biosens Bioelectron 32:1–1810.1016/j.bios.2011.10.054 ↗
7. Jung WG (ed) (2002) Op amp applications handbook. Analog devices (Online). http://www.analog.com/library/analogdialogue/archives/39-05/op_amp_applications_handbook.html
8. Kobayashi N, Li YJ, Naitoh Y, Kageshima M, Sugawara Y (2010) High force sensitivity in Q-controlled phase-modulation atomic force microscopy. Appl Phys Lett 97:01190610.1063/1.3457431 ↗
9. Kucera M, Manzaneque T, Sánchez-Rojas JL, Bittner A, Schmid U (2013a) Q-factor enhancement for self-actuated self-sensing piezoelectric MEMS applying a lock-in driven feedback loop. J Micromech Microeng 23:08500910.1088/0960-1317/23/8/085009 ↗
10. Kucera M, Hofbauer F, Manzaneque T, Ruiz V, Sanchez-Rojas JL, Bittner A, Schmid U (2013b) Quality factor enhancement for resonant MEMS applying an analogue feedback circuit driven by a lock-in amplifier. Proc SPIE Smart Sens, Actuators, MEMS VI 8763:87630W. doi: 10.1117/12.201713110.1117/12.2017131 ↗
11. Kwon TY, Eom K, Park JH, Yoon DS, Kimc TS, Lee HL (2007) In situ real-time monitoring of biomolecular interactions based on resonating microcantilevers immersed in a viscous fluid. Appl Phys Lett 90:22390310.1063/1.2741053 ↗
12. Lavrik NV, Sepaniak MJ, Datskos PG (2004) Cantilever transducers as a platform for chemical and biological sensors. Rev Sci Instrum 75:222910.1063/1.1763252 ↗
13. Malo J, Izpura J-I (2009) Feedback-induced phase noise in microcantilever-based oscillators. Sens Actuator A 155:188–19410.1016/j.sna.2009.08.001 ↗
14. Manzaneque T, Hernando-García J, Ababneh A, Seidel H, Schmid U, Sánchez-Rojas JL (2011) Quality-factor amplification in piezoelectric MEMS resonators applying an all-electrical feedback loop. J Micromech Microeng 21:02500710.1088/0960-1317/21/2/025007 ↗
15. Manzaneque T, Ruiz V, Hernando-García J, Ababneh A, Seidel H, Sánchez-Rojas JL (2012) Characterization and simulation of the first extensional mode of rectangular micro-plates in liquid media. Appl Phys Lett 101:15190410.1063/1.4758470 ↗
16. Ramus X (2009) Transimpedance considerations for high-speed amplifiers. Texas instruments application report SBOA122-Nov 2009 (Online 02.08.2013), http://www.ti.com/lit/an/sboa122/sboa122.pdf
17. Sanchez-Rojas JL, Hernando J, Donoso A, Bellido JC, Manzaneque T, Ababneh A, Seidel H, Schmid U (2010) Modal optimization and filtering in piezoelectric microplate resonators. J Micromech Microeng 20:05502710.1088/0960-1317/20/5/055027 ↗
18. Tamayo J (2005) Study of the noise of micromechanical oscillators under quality factor enhancement via driving force control. J Appl Phys 97:04490310.1063/1.1847729 ↗
19. Tamayo J, Humphris ADL, Malloy AM, Miles MJ (2001) Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. Ultramicroscopy 86:167–17310.1016/S0304-3991(00)00082-6 ↗
20. Tao Y, Li X, Xu T, Yu H, Xu P, Xiong B, Wei C (2011) Resonant cantilever sensors operated in a high-Q in-plane mode for real-time bio/chemical detection in liquids. Sens Actuators B 157:606–61410.1016/j.snb.2011.05.030 ↗
21. Wasisto HS, Merzsch S, Andreas Waag, Uhde E, Salthammer T, Peiner E (2013) Portable cantilever-based airborne nanoparticle detector. Sens Actuator B 187:118–12710.1016/j.snb.2012.09.074 ↗
22. Ziegler C (2004) Cantilever-based biosensors. Anal Bioanal Chem 379:946–959