journal article·2017-08

Design and experimental research on piezoelectric pump with triple vibrators

Jing Shi Dong, Wen Hua Chen, Ping Zeng, Rui Gang Liu, Chuanliang Shen, Wei Shuai Liu, Quan Qu Chen, Yang Yang, Yue Wu, Zhi Gang Yang, Bai Song Lin

Microsystem Technologies· Volume 23· Issue 8
Publisher page

Abstract

A new kind of piezoelectric pump with triple vibrators was presented. The pump adopted circular piezoelectric vibrator with a hole in the middle, and a check valve was adhered to the hole to cut off air. The working principle of the pump was analyzed. A prototype of piezoelectric pump was fabricated and measured. The experimental results show: (1) The maximum flow rate of the piezoelectric pump under the working mode of vibrators 1, and 3 driven synchronously and vibrator 2 driven asynchronously reached to 1513.2 mL/min when driving frequency was 220 Hz, and the maximum pressure reached to 4.08 kPa when that was 140 Hz. (2) The output performance of the piezoelectric pump with triple vibrators was the best under the working mode of vibrators 1, and 3 driven synchronously and vibrator 2 driven asynchronously. (3) When only two vibrators participate in working, the best connection method was vibrator 1 not driven and vibrators 2, and 3 driven asynchronously. (4) When only one vibrator participates in working, the best connection method was vibrator 3 driven solely.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Hydraulic and Pneumatic Systems · Piezoelectric Actuators and Control

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. de Lima CR, Vatanabe SL, Choi A et al (2009) A biomimetic piezoelectric pump: computational and experimental characterization[J]. Sens Actuators A 152(1):110–11810.1016/j.sna.2009.02.038 ↗
2. Guo-jun L, Zun-qiang F, Jing-shi D et al (2007) Piezoelectric micro pump for insulin injection[J]. J Jilin Univ Eng Technol Ed 37(2):372–376
3. Jang LS, Li YJ, Lin SJ et al (2007) A stand-alone peristaltic micropump based on piezoelectric actuation[J]. Biomed Microdevices 9(2):185–19410.1007/s10544-006-9020-8 ↗
4. Jing-shi D, Guang-ming C, Chuan-liang S et al (2007) Piezoelectric insulin pump[J]. J Xi’an Jiaotong Univ 41(5):602–605
5. Kan JW, Yang Z, Cheng GM (2002) Research on piezoelectric pump and its development[J]. Optic Precis Eng 10(6):619–625
6. Ma HK, Hou BR, Wu HY et al (2008a) Development and application of a diaphragm micro-pump with piezoelectric device[J]. Microsyst Technol 14(7):1001–100710.1007/s00542-007-0462-6 ↗
7. Ma HK, Hou BR, Gao JJ et al (2008b) Development of one-sided actuating piezoelectric micropump combined with cold plate in a laptop. In: Semiconductor thermal measurement and management symposium, 2008. Semi-Therm, 24th Annual IEEE. IEEE, 2008, pp 124–13110.1109/STHERM.2008.4509378 ↗
8. Ma HK, Hou BR, Lin CY et al (2008c) The improved performance of one-side actuating diaphragm micropump for a liquid cooling system[J]. Int Commun Heat Mass Transfer 35(8):957–96610.1016/j.icheatmasstransfer.2008.04.002 ↗
9. Ma HK, Chen BR, Gao JJ et al (2009) Development of an OAPCP-micropump liquid cooling system in a laptop[J]. Int Commun Heat Mass Transf 36(3):225–23210.1016/j.icheatmasstransfer.2008.11.014 ↗
10. Peng TJ, Yang ZG, Cheng GM et al (2009) Design of double-chamber piezoelectric pump[J]. Optics Precis Eng 17(5):1078–1085
11. Zhang Z, Kan J, Wang S et al (2013) Flow rate self-sensing of a pump with double piezoelectric actuators[J]. Mech Syst Signal Process 41(1):639–64810.1016/j.ymssp.2013.08.012 ↗