Micromachined pyramidal shaped biodegradable microneedle and its skin penetration capability
Source abstract
Abstract
A biodegradable pyramidal shaped microneedle array made of hyaluronic acid-based material was fabricated by anisotropic wet etching and a molding process. First, pyramidal shaped needles were fabricated on a Si wafer by anisotropic wet etching as an original master and then a mixture of two biodegradable materials, hyaluronic acid and a collagen, were replicated with the same shape as the original Si needle by a molding process. The height and pitch of the needle were 0.21 and 0.62 mm, respectively. The tip radius in the replicated biodegradable needle became 0.005 mm. The penetration capability of the needle arrays was evaluated by applying the load to skin multiple times. Results showed that both the Si and biodegradable needle arrays could successfully penetrate silicone rubber sheets with the applied load of 100 g. The developed biodegradable needle arrays also successfully penetrated mouse skin with the load of 50 g.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Transdermal Drug Delivery · Neuroscience and Neural Engineering · Optical Coherence Tomography Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Barry B, Williams A (2003) Penetration enhancers. Adv Drug Deliv Rev 56:603–618
2. Davis SP, Prausnitz MR, Allen MG (2003) Fabrication and characterization of laser micromachined hollow microneedles, Tech. In: Digest of the 12th international conference on solid-state sensors, actuators, and microsystems, pp 1435–143810.1109/SENSOR.2003.1217045 ↗
3. Griss P, Stemme G (2002) Novel, side opened out-of-plane microneedles for microfluidic transdermal interfacing, Tech. In: Digest of the 15th international IEEE micro electro mechanical conference, pp 467–470
4. Henry S, McAllister DV, Allen MG, Prausnitz MR (1998) Micromachined needles for the transdermal delivery of drugs, Proc. Micro Electro Mechanical Systems Workshop, pp 494–498
5. Kim J, Paik SJ, Wang PC, Kim SH, Allen MG (2011) Maskless fabrication of high aspect ratio structures by combination of micromolding and direct drawing, Tech. In: Digest of the 24th international IEEE micro electro mechanical conference, pp 280–283
6. Ledger PW (1992) Skin biological issues in electrically enhanced transdermal delivery. Adv Drug Deliv Rev 9:289–30710.1016/0169-409X(92)90027-N ↗
7. Mansoor I, Häfeli UO, Stoeber B (2011) Array of solvent cast hollow out-of-plane polymer microneedles for drug delivery, Tech. In: Digest of the 24th international IEEE micro electro mechanical conference, pp 1027–1030
8. Mansoor I, Liu Y, Häfeli UO, Stoeber B (2013) Fabrication of hollow microneedle arrays using electrodeposition of metal onto solvent cast conductive polymer structures, Tech. In: Digest of the 17th international conference on solid-state sensors, actuators, and microsystems, pp 373–376
9. Mitragotri S, Kost J (2004) Low-frequency sonophoresis: a review. Adv Drug Deliv Rev 56:589–60110.1016/j.addr.2003.10.024 ↗
10. Paik SJ, Kim SH, Wang PC, Wester BA, Allen MG (2010) Dissolvable-tipped, drug-reservoir integrated microneedle array for transdermal drug delivery, Tech. In: Digest of the 23rd international IEEE micro electro mechanical conference, pp 312–315
11. Park JH, Davis S, Yoon YK, Prausnitz MR, Allen MG (2003) Micromachined biodegradable microstructures, Tech. In: Digest of the 16th international IEEE micro electro mechanical conference, pp 371–374
12. Park JH, Yoon YK, Prausnitz MR, Allen MG (2004), High-aspect-ratio tapered structures using an integrated lens technique, Tech. In: Digest of The 17th international IEEE micro electro mechanical conference, pp 383–386
13. Preat V, Vanbever R (2004) Skin electroporation for transdermal and topical delivery. Adv Drug Deliv Rev 56:659–67410.1016/j.addr.2003.10.027 ↗
14. Roxhed N, Griss P, Stemme G (2005a) Generic leak-free drug storage and delivery for microneedle-based systems, Tech. In: Digest of the 18th international IEEE micro electro mechanical conference, pp 742–74510.1109/MEMSYS.2005.1454036 ↗
15. Roxhed N, Griss P, Stemme G (2005b) Reliable in vivo penetration and transdermal injection using ultra-sharp hollow microneedles, Tech. In: Digest of the 13th international conference on solid-state sensors, actuators, and microsystems, pp 213–21610.1109/SENSOR.2005.1496396 ↗
16. Roxhed N, Samel B, Nordquist L, Griss P, Stemme G (2006) Compact, seamless integration of active dosing and actuation with microneedles for transdermal drug delivery, Tech. In: Digest of the 19th international IEEE micro electro mechanical conference, pp 414–41710.1109/MEMSYS.2006.1627824 ↗
17. Roxhed N, Griss P, Stemme G (2007) Tapered deep reactive ion etching: method and characterization, Tech. In: Digest of the 14th international conference on solid-state sensors, actuators, and microsystems, pp 493–49610.1109/SENSOR.2007.4300175 ↗
18. Shikida M, Ando M, Ishihara Y, Ando T, Sato K, Asaumi K (2004a) Non-photolithographic pattern transfer for fabricating pen-shaped microneedle structures. J Micromech Microeng 14:1462–146710.1088/0960-1317/14/11/005 ↗
19. Shikida M, Odagaki M, Todoroki N, Ando M, Ishihara Y, Ando T, Sato K (2004b) Non-photolithographic pattern transfer for fabricating arrayed three-dimensional microstructures by chemical anisotropic etching. Sens Actuators A 116:264–27110.1016/j.sna.2004.04.031 ↗
20. Shikida M, Hasada T, Sato K (2006a) Fabrication of densely arrayed micro-needles with flow channels by mechanical dicing and anisotropic wet etching. J Micromech Microeng 16:1740–174710.1088/0960-1317/16/8/039 ↗
21. Shikida M, Hasada T, Sato K (2006b) Fabrication of a hollow needle structure by dicing, wet etching, and metal deposition. J Micromech Microeng 16:2230–223910.1088/0960-1317/16/10/041 ↗
22. Trautmann A, Ruther P, Paul O (2003) Microneedle arrays fabricated using suspended etch mask technology combined with fluidic through wafer vias, Tech. In: Digest of the 16th international IEEE micro electro mechanical conference, pp 682–685
23. Trautmann A, Heuck F, Denfeld R, Ruther P, Paul O (2006) Detachable silicon microneedle stamps for allergy skin prick testing, Tech. In: Digest of the 19th international IEEE micro electro mechanical conference, pp 434–43710.1109/MEMSYS.2006.1627829 ↗
24. Wang PC, Paik SJ, Kim J, Kim SH, Allen MG (2011) Hypodermic-needle-like hollow polymer microneedle array using UV lithography into micromolds, Tech. In: Digest of the 24th international IEEE micro electro mechanical conference, pp 1039–1042