Development of a capillary flow microfluidic Escherichia coli biosensor with on-chip reagent delivery using water-soluble nanofibers
Source abstract
Abstract
Although the potential role of microfluidics in point of care diagnostics is widely acknowledged, the practical limitations to their use still limit deployment. Here, we developed a capillary flow microfluidic with on-chip reagent delivery which combines a lateral flow assay with microfluidic technology. The horseradish peroxidase tagged antibody was electrospun in a water-soluble polyvinylpyrrolidone nanofibers and stored in a microfluidic poly(methyl methacrylate) chip. During the assay, the sample containing Escherichia coli on immunomagnetic beads came in contact with the nanofibers causing them to dissolve and release the reagents for binding. Following hybridization, the solution moved by capillary flow toward a detection zone where the analyte was quantified using chemiluminescence. The limit of detection was found to be approximately 106 CFU/mL of E. coli O157. More importantly, the ability to store sensitive reagents within a microfluidic as nanofibers was demonstrated. The fibers showed almost instant hydration and dissemination within the sample solution.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Biosensors and Analytical Detection · Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Boehm DA, Gottlieb PA, Hua SZ (2007) On-chip microfluidic biosensor for bacterial detection and identification. Sens Actuators B-Chem 126:508–51410.1016/j.snb.2007.03.043 ↗
2. Du Z, Cheng KH, Vaughn MW, Collie NL, Gollahon LS (2007) Recognition and capture of breast cancer cells using an antibody-based platform in a microelectromechanical systems device. Biomed Microdevices 9:35–4210.1007/s10544-006-9010-x ↗
3. Gervais L, Delamarche E (2009) Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab Chip 9:3330–333710.1039/b906523g ↗
4. Graf NJ, Bowser MT (2008) A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump. Lab Chip 8:1664–167010.1039/b805252b ↗
5. He F, Wang Y, Jin S, Nugen SR (2011) Development of a capillary-driven, microfluidic, nucleic acid biosensor. Sens Transducers 13:150–158
6. Hong C, Chang P, Lin C, Hong C (2010) A disposable microfluidic biochip with on-chip molecularly imprinted biosensors for optical detection of anesthetic propofol. Biosens Bioelectron 25:2058–206410.1016/j.bios.2010.01.037 ↗
7. Jin S, Dai M, He F, Wang Y, Ye B, Nugen SR (2012) Development and characterization of a capillary-flow microfluidic device for nucleic acid detection. Microsyst Technolo Micro Nanosyst Inf Storage Process Syst 18:731–73710.1007/s00542-012-1487-z ↗
8. Jung W, Jang A, Bishop PL, Ahn CH (2011) A polymer lab chip sensor with microfabricated planar silver electrode for continuous and on-site heavy metal measurement. Sens Actuators B-Chem 155:145–15310.1016/j.snb.2010.11.039 ↗
9. Konry T, Bale SS, Bhushan A, Shen K, Seker E, Polyak B, Yarmush M (2012) Particles and microfluidics merged: perspectives of highly sensitive diagnostic detection. Microchim Acta 176:251–26910.1007/s00604-011-0705-1 ↗
10. Krogmeier JR, Schaefer I, Seward G, Yantz GR, Larson JW (2007) An integrated optics microfluidic device for detecting single DNA molecules. Lab Chip 7:1767–177410.1039/b710504e ↗
11. Lefevre F, Chalifour A, Yu L, Chodavarapu V, Juneau P, Izquierdo R (2012) Algal fluorescence sensor integrated into a microfluidic chip for water pollutant detection. Lab Chip 12:787–79310.1039/C2LC20998E ↗
12. Liu C, Qiu X, Ongagna S, Chen D, Chen Z, Abrams WR, Malamud D, Corstjens PLAM, Bau HH (2009) A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids. Lab Chip 9:768–77610.1039/B814322F ↗
13. Mubammad-Tahir Z, Alocilja E (2003) A conductometric biosensor for biosecurity. Biosens Bioelectron 18:813–81910.1016/S0956-5663(03)00020-4 ↗
14. Nugen SR, Leonard B, Baeumner AJ (2007) Application of a unique server-based oligonucleotide probe selection tool toward a novel biosensor for the detection of Streptococcus pyogenes. Biosens Bioelectron 22:2442–244810.1016/j.bios.2006.09.002 ↗
15. Nugen SR, Asiello PJ, Connelly JT, Baeumner AJ (2009) PMMA biosensor for nucleic acids with integrated mixer and electrochemical detection. Biosens Bioelectron 24:2428–243310.1016/j.bios.2008.12.025 ↗
16. Qi SZ, Liu XZ, Ford S, Barrows J, Thomas G, Kelly K, McCandless A, Lian K, Goettert J, Soper SA (2002) Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection. Lab Chip 2:88–9510.1039/b200370h ↗
17. Weigl B, Domingo G, LaBarre P, Gerlach J (2008) Towards non- and minimally instrumented, microfluidics-based diagnostic devices. Lab Chip 8:1999–201410.1039/b811314a ↗
18. Yamahata C, Lotto C, Al-Assaf E, Gijs M (2005) A PMMA valveless micropump using electromagnetic actuation. Microfluid Nanofluid 1:197–20710.1007/s10404-004-0007-6 ↗