Fast fabrication of microfluidic devices using a low-cost prototyping method
Source abstract
Abstract
Conventional ways to produce microfluidic devices cost a lot due to the requirements for cleanroom environments and expensive equipment, which prevents the wider applications of microfluidics in academia and in industry. In this paper, a dry film photoresist was utilized in a simple way to reduce the fabrication cost of microfluidic masters. Thus, a fast prototyping and fabrication of microstructures in polydimethylsiloxane microchips through a replica molding technology was achieved in a low-cost setting within 2.5 h. Subsequently, major manufacturing conditions were optimized to acquire well-resolved microfluidic molds, and the replicated microchips were validated to be of good performance. A T-junction channel microchip was fabricated by using a dry film master to generate water droplets of uniform target size. Meanwhile, a gated injection of fluorescein sodium and a contactless conductivity detection of Na+ were both performed in a crosslink channel microchip via capillary electrophoresis, in other words, this fast prototyping and fabrication method would be an efficient, economical way to embody structural design into microfluidic chips for various applications.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Innovative Microfluidic and Catalytic Techniques Innovation · Electrowetting and Microfluidic Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Anderson JR, Chiu DT, Wu H, Schueller OJ, Whitesides GM (2000) Fabrication of microfluidic systems in poly (dimethylsiloxane). Electrophoresis 21:27–4010.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO;2-C ↗
2. Ansari K, Ying JYS, Hauser PC, Rooij NF, Rodriguez I (2013) A portable lab-on-a-chip instrument based on MCE with dual top-bottom capacitive coupled contactless conductivity detector in replaceable cell cartridge. Electrophoresis 34:1390–139910.1002/elps.201200592 ↗
3. Chen C, Hahn JH (2007) Dual-channel method for interference-free in-channel amperometric detection in microchip capillary electrophoresis. Anal Chem 79:7182–718610.1021/ac070721h ↗
4. Chen Z, Gao Y, Su R, Li C, Lin J (2003) Fabrication and characterization of poly (methyl methacrylate) microchannels by in situ polymerization with a novel metal template. Electrophoresis 24:3246–325210.1002/elps.200305534 ↗
5. Chen C, Zhu Y, Leech PW, Manasseh R (2009) Production of monodispersed micron-sized bubbles at high rates in a microfluidic device. Appl Phys Lett 95:144101–14410310.1063/1.3242019 ↗
6. Chen C, Teng W, Hahn JH (2011) Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis. Electrophoresis 32:838–84310.1002/elps.201000661 ↗
7. Dongre C, van Weerd J, Besselink GA, van Weeghel R, Vazquez RM, Osellame R, Cerullo G, Cretich M, Chiari M, Hoekstra HJ (2010) High-resolution electrophoretic separation and integrated-waveguide excitation of fluorescent DNA molecules in a lab on a chip. Electrophoresis 31:2584–258810.1002/elps.201000126 ↗
8. Fredlake CP, Hert DG, Niedringhaus TP, Lin JS, Barron AE (2012) Divergent dispersion behavior of ssDNA fragments during microchip electrophoresis in pDMA and LPA entangled polymer networks. Electrophoresis 33:1411–142010.1002/elps.201100686 ↗
9. Friend J, Yeo L (2010) Fabrication of microfluidic devices using polydimethylsiloxane. Biomicrofluidics 4:26502–2650710.1063/1.3259624 ↗
10. Fu L, Yang R, Lee G, Liu H (2002) Electrokinetic injection techniques in microfluidic chips. Anal Chem 74:5084–509110.1021/ac025821w ↗
11. Guijt RM, Armstrong JP, Candish E, Lefleur V, Percey WJ, Shabala S, Hauser PC, Breadmore MC (2011) Microfluidic chips for capillary electrophoresis with integrated electrodes for capacitively coupled conductivity detection based on printed circuit board technology. Sens Actuators B Chem 159:307–31310.1016/j.snb.2011.06.023 ↗
12. Gunther A, Khan SA, Thalmann M, Trachsel F, Jensen KF (2004) Transport and reaction in microscale segmented gas-liquid flow. Lab Chip 4:278–28610.1039/B403982C ↗
13. Huang Y, Du W, Pan J, Fang Q (2008) Microfluidic chip-based valveless flow injection analysis system with gravity-driven flows. Analyst 133:1237–124110.1039/b807494a ↗
14. Ibarlucea B, Diez-Gil C, Ratera I, Veciana J, Caballero A, Zapata F, Tarraga A, Molina P, Demming S, Buttgenbach S (2013) PDMS based photonic lab-on-a-chip for the selective optical detection of heavy metal ions. Analyst 138:839–84410.1039/C2AN36402F ↗
15. Kim J, Hwang I, Britain D, Chung TD, Sun Y, Kim D (2011) Microfluidic approaches for gene delivery and gene therapy. Lab Chip 11:3941–394810.1039/c1lc20766k ↗
16. Li Q, Pei J, Song P, Kennedy RT (2010) Fraction collection from capillary liquid chromatography and off-line electrospray ionization mass spectrometry using oil segmented flow. Anal Chem 82:5260–526710.1021/ac100669z ↗
17. Lin C, Lee G, Chang B, Chang G (2002) A new fabrication process for ultra-thick microfluidic microstructures utilizing SU-8 photoresist. J Micromech Microeng 12:590–59710.1088/0960-1317/12/5/312 ↗
18. Luo C, Yang X, Fu Q, Sun M, Ouyang Q, Chen Y, Ji H (2006) Picoliter-volume aqueous droplets in oil: electrochemical detection and yeast cell electroporation. Electrophoresis 27:1977–198310.1002/elps.200500665 ↗
19. Martinez-Duarte R (2012) Microfabrication technologies in dielectrophoresis applications: review. Electrophoresis 33:3110–313210.1002/elps.201200242 ↗
20. Minarik M, Kopeckova M, Gassman M, Osmancik P, Benesova L (2012) Rapid testing of clopidogrel resistance by genotyping of CYP2C19 and CYP2C9 polymorphisms using denaturing on-chip capillary electrophoresis. Electrophoresis 33:1306–131010.1002/elps.201100457 ↗
21. Neuzi P, Giselbrecht S, Lange K, Huang TJ, Manz A (2012) Revisiting lab-on-a-chip technology for drug discovery. Nat Rev Drug Discov 11:620–63210.1038/nrd3799 ↗
22. Okushima S, Nisisako T, Torii T, Higuchi T (2004) Controlled production of monodisperse double emulsions by two-step droplet breakup in microfluidic devices. Langmuir 20:9905–990810.1021/la0480336 ↗
23. Osaki T, Yoshizawa S, Kawano R, Sasaki H, Takeuchi S (2011) Lipid-coated microdroplet array for in vitro protein synthesis. Anal Chem 83:3186–319110.1021/ac2000048 ↗
24. Pei J, Li Q, Kennedy RT (2010) Rapid and label-free screening of enzyme inhibitors using segmented flow electrospray ionization mass spectrometry. J Am Soc Mass Spectr 21:1107–111310.1016/j.jasms.2010.02.013 ↗
25. Reiser A (1989) Photoreactive polymers: the science and technology of resists. Wiley, New York
26. Srisa-Art M, Bonzani IC, Williams A, Stevens MM, Edel JB (2009) Identification of rare progenitor cells from human periosteal tissue using droplet microfluidics. Analyst 134:2239–224510.1039/b910472k ↗
27. Stephan K, Pittet P, Renaud L, Kleimann P, Morin P, Ouaini N, Ferrigno R (2007) Fast prototyping using a dry film photoresist: microfabrication of soft-lithography masters for microfluidic structures. J Micromech Microeng 17:N69–N7410.1088/0960-1317/17/10/N01 ↗
28. Tantra R, Robinson K, Sikora A (2014) Variability of microchip capillary electrophoresis with conductivity detection. Electrophoresis 35:263–27010.1002/elps.201300175 ↗
29. Tsai Y, Jen H, Lin K, Hsieh Y (2006) Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis. J Chromatogr A 1111:267–27110.1016/j.chroma.2005.12.003 ↗
30. Vulto P, Glade N, Altomare L, Bablet J, Del Tin L, Medoro G, Chartier I, Manaresi N, Tartagni M, Guerrieri R (2005) Microfluidic channel fabrication in dry film resist for production and prototyping of hybrid chips. Lab Chip 5:158–16210.1039/b411885e ↗
31. Wegrzyn J, Samborski A, Reissig L, Korczyk PM, Blonski S, Garstecki P (2013) Microfluidic architectures for efficient generation of chemistry gradations in droplets. Microfluid Nanofluid 14:235–24510.1007/s10404-012-1042-3 ↗
32. Wu W, Lee NY (2012) Flow-through PCR on a 3D qiandu-shaped polydimethylsiloxane (PDMS) microdevice employing a single heater: toward microscale multiplex PCR. Analyst 137:2069–207610.1039/c2an35077g ↗
33. Wu N, Courtois F, Surjadi R, Oakeshott J, Peat TS, Easton CJ, Abell C, Zhu Y (2011) Enzyme synthesis and activity assay in microfluidic droplets on a chip. Eng Life Sci 11:157–16410.1002/elsc.201000043 ↗
34. Zhou J, Ellis AV, Voelcker NH (2010) Recent developments in PDMS surface modification for microfluidic devices. Electrophoresis 31:2–1610.1002/elps.200900475 ↗
35. Zhu Y, Power BE (2008) Lab-on-a-chip in vitro compartmentalization technologies for protein studies. Adv Biochem Eng Biot 110:81–114