journal article·2018-08

Catheter type thermal flow sensor with small footprint for measuring breathing function

Y. Hasegawa, H. Kawaoka, Y. Mitsunari, M. Matsushima, T. Kawabe, M. Shikida

Microsystem Technologies· Volume 24· Issue 8
Publisher page

Abstract

We preivously developed a catheter type flow sensor for measuring breathing and heartbeat information from breathing at the mouth [Hasegawa et al. J Micromech Microeng 27(12): 125016, (2017); Kawaoka et al. Tech. Dig. IEEE Micro Electro Mechanical Systems Conference 2016, pp 359–362]. In this study, we redesigned and developed the new sensor configuraiton for the catheter flow sensor to downsize and improve the sensor characteristics. The previous flow sensor consists of two pairs of a heater and a temperature compensation sensor for flow rate detection. The two heaters also functioned not only for flow rate detection but also for flow direction detection. The two temperature compensation sensors had a large footprint and corresponded to each heater. Therefore, the sensor occupied a large area, and it was necessary to match the heater characteristics for flow rate detection. The newly designed sensor is composed of a set of a heater and a temperature compensation sensor and two flow direction sensors. By providing the new flow direction sensors, the number of temperature compensation sensors with a large footprint was reduced to one. Thus, the area of the new sensor design was 15.0 mm2, which was reduced to 54.5% of the 27.0 mm2 of the previous sensor area by providing the flow direction sensors. Then, the new catheter type flow sensor was fabricated, and the flow characteristics for measuring breathing funciton were evaluated. Finally, we applied the catheter type flow sensor to an animal experiment using a rat, and it could evaluate the flow rate characteristics of the rat’s breathing as a reciprocating flow including flow direction. Moreover, the obtained breathing characteristics were within the range of the physiological values of rats.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Chemical Sensor Technologies · Microfluidic and Capillary Electrophoresis Applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Akifumi S (2009) Hitachi Mappie CMUT Ultrasound Probe. http://www.hitachi.co.jp/products/healthcare/products-support/contents/medix/pdf/vol51/P31-34.pdf
2. Chandra NC, Hazinski MF (1997) American Red cross basic life support for healthcare providers handbook. American Red Cross, Washington, D.C.
3. Demirci U, Oralkan O, Johnson JA, Ergun AS, Karaman M, Khuri-Yakub BT (2001) Capacitive micromachined ultrasonic transducer arrays for medical imaging: experimental results. In: Ultrasonics Symposium, 2001 IEEE, Atlanta GA, vol 2, pp 957–960, 7–10 Oct 2001
4. Hasegawa Y, Kawaoka H, Yamada T, Matsushima M, Kawabe T, Shikida M (2017) Respiration and heartbeat signal detection from airflow at airway in rat by catheter flow sensor with temparature compensation function. J Micromech Microeng 27(12):12501610.1088/1361-6439/aa9595 ↗
5. Jovanov E, Raskovic D, Hormigo R (2001) Thermistor-based breathing sensor for circadian rhythm evaluation. In: Proc. 38th Annu. Rocky Mountain Bioengineering Symp. RMBS 2001, pp 493–497, 2001 Apr
6. Kawaoka H, Yamada T, Matsushima M, Kawabe T, Shikida M (2015a) Detection of both heartbeat and respiration signals from airflow at mouth by using single catheter flow sensor. In: Tech. Digest of the 18th international conference on solid-state sensors, actuators and microsystems, Anchorage, USA, 2015, pp 1755–175810.1109/TRANSDUCERS.2015.7181285 ↗
7. Kawaoka H, Yamada T, Matsushima M, Kawabe T, Hasegawa Y, Shikida M (2015b) Extraction of heartbeat signal from airflow at mouth by flow sensor. In: Proceedings of IEEE sensors conference, Busan, Nov 2015, pp 279–28210.1109/ICSENS.2015.7370234 ↗
8. Kawaoka H, Yamada T, Matsushima M, Kawabe T, Hasegawa Y, Shikida M (2016) Detection of kinetic heartbeat signals from airflow at mouth by catheter flow sensor with temperature compensation. In: Tech Dig IEEE micro electro mechanical systems conference, Shanghai, China, Jan 2016, pp 359–36210.1109/MEMSYS.2016.7421635 ↗
9. Kawaoka H, Yamada T, Matsushima M, Kawabe T, Hasegawa Y, Shikida M (2017) Heartbeat signal detection from analysis of airflow in rat airway under different depths of anesthesia conditions. IEEE Sens J 17(14):4369–437710.1109/JSEN.2017.2707594 ↗
10. Khuri-Yakub BT, Oralkan O (2011) Capacitive micromachined ultrasonic transducers for medical imaging and therapy. J Micromech Microeng 21(5):54004–5401510.1088/0960-1317/21/5/054004 ↗
11. King LV (1914) On the convection of heat from small cylinders in a stream of fluid: determination of the convection constants of small platinum wires with applications to hot-wire anemometry. Philos Trans R Soc Lond A 214:373–43210.1098/rsta.1914.0023 ↗
12. Liu LY, Keeler EG (2015) Progress of MEMS scanning micromirrors for optical bio-imaging. Micromachines 6:1675–168910.3390/mi6111450 ↗
13. Lu CD, Kraus MF, Potsaid B (2014) Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror. Biomed Opt Express 5:293–31110.1364/BOE.5.000293 ↗
14. Mitsunari Y, Hasegawa Y, Matsushima M, Kawabe T, Shikida M (2017) Development of small-footprint thermal sensor detecting airflow at mouth in baby. In: Proceedings of Eurosensors2017 conference. https://doi.org/10.3390/proceedings104035910.3390/proceedings1040359 ↗
15. Shikida M, Naito J, Yokota T, Kawabe T, Hayashi Y, Sato K (2009) A catheter-type flow sensor for measurement of aspirated- and inspired-air characteristics in the bronchial region. J Micromech Microeng 19:10502710.1088/0960-1317/19/10/105027 ↗
16. Shikida M, Yokota T, Kawabe T, Funaki T, Matsushima M, Iwai S, Matsunaga N, Sato K (2010) Characteristics of an optimized catheter-type thermal flow sensor for measuring reciprocating airflows in bronchial pathways. J Micromech Microeng 20:12503010.1088/0960-1317/20/12/125030 ↗
17. Shikida M, Yoshikawa K, Matsuyama T, Yamazaki Y, Matsushima M, Kawabe T (2014) Catheter flow sensor with temperature compensation for tracheal intubation tube system. Sens Actuators A 215:155–16010.1016/j.sna.2013.08.004 ↗