A flexible polyimide cable for implantable neural probe arrays
Source abstract
Abstract
A flexible polyimide cable developed for implantable neural probe array application is presented. The flexible cable is used to connect two implantable platforms--one in direct touch with the brain containing a neural probe array and its interface IC, and the other on the skull including a wireless link IC, a coil and an antenna for power and data transfer through the transcutaneous link. The cable needs to be highly flexible to minimize post-insertion injury caused by the probe array in the presence of brain micro-motion. Polyimide is used to form a flexible substrate and an insulator layer of the cable. For the advanced neural recording system, a large amount of neural recording data has to be communicated between the two platforms through the flexible cable. High-rate data transmission performance of the fabricated flexible cable is characterized and discussed. The measured insertion loss (IL) of the flexible cable is less than 3 dB and the isolation between two adjacent interconnects is better than 17 dB up to 2 GHz. The data transmission through the flexible cable is verified to be highly reliable at 100 Mbps. For surgical manipulation and long term implantation of the neural probe microsystem, the flexible cable needs to have excellent mechanical strength and resistance to fatigue. The mechanical characteristics and fatigue strength of the flexible cable are also measured and discussed. The measured maximum tensile stress and strain of the flexible cable before failure are 251.2 ± 7.1 MPa (14.35 ± 0.3 N) and 4.16 ± 0.11 %, respectively. The Young's modulus of the fabricated flexible cable is 8.21 GPa. From the fatigue strength testing, the measured resistance change of the flexible cable's interconnect is less than 4.8 % after 250,000 cycles of cyclic mechanical stretch.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Bai Q, Wise KD, Anderson DJ (2000) A high-yield microassembly structure for three-dimensional microelectrode arrays. IEEE Trans Bio Med Eng 47:281–28910.1109/10.827288 ↗
2. Eisenstadt WR, Eo Y (1992) S-parameter-based IC interconnect transmission line characterization. IEEE Trans Compon Hybrids Manuf Technol 15:483–49010.1109/33.159877 ↗
3. Goldstein SR, Salcman M (1973) Mechanical factors in design of chronic recording intracortical microelectrodes. IEEE Trans Bio Med Eng 20:260–26910.1109/TBME.1973.324190 ↗
4. Herwik S, Kisban S, Aarts AAA, Seidl K, Girardeau G, Benchenane K, Zugaro MB, Wiener SI, Paul O, Neves HP, Ruther P (2009) Fabrication technology for silicon-based microprobe arrays used in acute and sub-chronic neural recording. J Micromech Microeng 19:1–1110.1088/0960-1317/19/7/074008 ↗
5. Hetke JF, Lund JL, Najafi K, Wise KD, Anderson DJ (1994) Silicon ribbon cables for chronically implantable microelectrode arrays. IEEE Trans Bio Med Eng 41:314–32110.1109/10.284959 ↗
6. Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP (2006) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 442:164–17110.1038/nature04970 ↗
7. Lee YT, Lin CW, Lin CM, Yeh SR, Chang YC, Fang W (2010) A pseudo 3D glass microprobe array: glass microprobe with embedded silicon for alignment and electrical interconnection during assembly. J Micromech Microeng 20:1–9
8. Meyer JU, Stieglitz T, Scholz O, Haberer W, Beutel H (2001) High density interconnects and flexible hybrid assemblies for active biomedical implants. IEEE Trans Adv Packag 24:366–37410.1109/6040.938305 ↗
9. Norlin P, Kindlundh M, Mouroux A, Yoshida K, Hofmann UG (2002) A 32-site neural recording probe fabricated by DRIE of SOI substrates. J Micromech Microeng 12:414–41910.1088/0960-1317/12/4/312 ↗
10. Pang C, Cham JG, Nenadic Z, Musallam S, Tai SC, Burdick JW, Andersen RA (2005) A new multi-site probe array with monolithieally integrated parylene flexible cable for neural prostheses. In: Prof of Intl Conf IEEE Eng Med and Bio, Shanghai, China, pp 7114–7117
11. Rousche PJ, Pellinen DS, Pivin DP, Williams JC, Vetter RJ, Kipke DR (2001) Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans Bio Med Eng 48:361–37110.1109/10.914800 ↗
12. Rubehn B, Stieglitz T (2010) In vitro evaluation of the long-term stability of polyimide as a material for neural implants. Biomaterials 31:3449–345810.1016/j.biomaterials.2010.01.053 ↗
13. Stieglitz T, Beutel HE, Schuettler M, Meyer JU (2000) Micromachined, polyimide-based devices for flexible neural interfaces. Biomed Microdevices 2:283–29410.1023/A:1009955222114 ↗
14. Takeuchi S, Suzuki T, Mabuchi K, Fujita H (2004) 3D flexible multichannel neural probe array. J Micromech Microeng 14:104–10710.1088/0960-1317/14/1/014 ↗
15. Velliste M, Perel S, Spalding MC, Whitford AS, Schwartz AB (2008) Cortical control of a prosthetic arm for self-feeding. Nature 453:1098–110110.1038/nature06996 ↗
16. Wise KD, Bhatti PT, Wang JB, Friedrich CR (2008) High-density cochlear implants with position sensing and control. Hearing Res 242:22–3010.1016/j.heares.2008.04.002 ↗
17. Yao Y, Gulari MN, Casey B, Wiler JA, Wise KD (2007) Silicon microelectrodes with flexible integrated cables for neural implant applications. In: Proc of EMBS Conf Neural Eng, Kohala Coast, pp 398–40110.1109/CNE.2007.369693 ↗