journal article·2019-07

MEMS based tin oxide thin film gas sensor for diabetes mellitus applications

Smiti Sachdeva, Ravinder Agarwal, Ajay Agarwal

Microsystem Technologies· Volume 25· Issue 7
Publisher page

Abstract

Breath analysis has gained interest of many researchers lately. Acetone has been proven to be the biomarker for diabetes mellitus. The research depicts a thin film MEMS based gas sensor for acetone gas detection. MEMS techniques have been followed to develop the gas sensor involving the processes like oxidation, lithography, sputtering for deposition of thin films and electrodes, etc. Tin oxide thin film has been incorporated for detecting different concentration levels of acetone gas, viz, 20, 10, 7, 5, 3, 1.5 ppm. Various characterization like X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), gas sensing characterization for recording resistance changes have been performed. XRD patterns reveal the formation of SnO2. AFM and SEM depict clear images of grain boundaries on the film. SnO2 thin films have been annealed at 300 °C to achieve an optimum grain size of 86.3 nm as depicted by AFM. Optimum operating temperature for sensing acetone gas has been computed to be 360 °C. Tin oxide can detect even a very low concentration of 1.5 ppm acetone gas with a good resistance response change of 30%. Apart from acetone gas, other interfering gases present in breath have also been tested. The sensor does not respond to them. The response time of the sensor for detection of acetone gas is approximately 3 min and the recovery time is approximately 4 min. A suitable instrumentation circuitry has also been designed for the sensor which displays the resistance value of the thin film before and after it comes in contact with acetone gas.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Analytical Chemistry and Sensors · Advanced Chemical Sensor Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Aoki A, Sasakura H (1970) Tin oxide thin film transistors. Jpn J Appl Phys 9(5):58210.1143/JJAP.9.582 ↗
2. Baik NS et al (2000) Hydrothermally treated sol solution of tin oxide for thin-film gas sensor. Sens Actuators B Chem 63(1-2):74–7910.1016/S0925-4005(99)00513-4 ↗
3. Baker B (1998) Precision temperature sensing with RTD circuits. AN687, Microchip Technology Inc, Chandler
4. Banerjee R, Das D (1987) Properties of tin oxide films prepared by reactive electron beam evaporation. Thin Solid Films 149(3):291–30110.1016/0040-6090(87)90392-0 ↗
5. Brattain WH, Bardeen J (1953) Surface properties of germanium. Bell Labs Tech J 32(1):1–4110.1002/j.1538-7305.1953.tb01420.x ↗
6. Carter B, Mancini R (2017) Op Amps for everyone. Newnes, Oxford
7. Choe Y-S (2001) New gas sensing mechanism for SnO2 thin-film gas sensors fabricated by using dual ion beam sputtering. Sen Actuators B Chem 77(1-2):200–20810.1016/S0925-4005(01)00731-6 ↗
8. Chopra KL, Major S, Pandya DK (1983) Transparent conductors—a status review. Thin Solid Films 102(1):1–4610.1016/0040-6090(83)90256-0 ↗
9. Comini E, Faglia G, Sberveglieri Gn (2001) UV light activation of tin oxide thin films for NO2 sensing at low temperatures. Sens Actuators B Chem 78(1–3):73–7710.1016/S0925-4005(01)00796-1 ↗
10. Dolbec R et al (2003) Influence of the nanostructural characteristics on the gas sensing properties of pulsed laser deposited tin oxide thin films. Sens Actuators B Chem 93(1–3):566–57110.1016/S0925-4005(03)00229-6 ↗
11. Durrani SMA et al (2002) Effect of preparation conditions on the optical and thermochromic properties of thin films of tungsten oxide. Sol Energy Mater Sol Cells 71(3):313–32510.1016/S0927-0248(01)00090-3 ↗
12. Durrani S et al (2012) Investigation of the carbon monoxide gas sensing characteristics of tin oxide mixed cerium oxide thin films. Sensors 12(3):2598–260910.3390/s120302598 ↗
13. Götz A et al (1997) Thermal and mechanical aspects for designing micromachined low-power gas sensors. J Micromech Microeng 7(3):24710.1088/0960-1317/7/3/045 ↗
14. Govender M et al (2013) Operating temperature effect in WO3 films for gas sensing. In: SENSORS, 2013 IEEE. IEEE10.1109/ICSENS.2013.6688192 ↗
15. Guo B et al (2017) Effects of nitrogen dioxide and carbon monoxide on the determination of sulfur dioxide by flue gas analyzer. MAPAN 32(4):265–27110.1007/s12647-017-0223-7 ↗
16. Horcas I et al (2007) WSXM: a software for scanning probe microscopy and a tool for nanotechnology. Rev Sci Instrum 78(1):01370510.1063/1.2432410 ↗
17. Kao K-W et al (2012) A sub-ppm acetone gas sensor for diabetes detection using 10 nm thick ultrathin InN FETs. Sensors 12(6):7157–716810.3390/s120607157 ↗
18. Khadayate RS, Sali JV, Patil PP (2007) Acetone vapor sensing properties of screen printed WO3 thick films. Talanta 72(3):1077–108110.1016/j.talanta.2006.12.043 ↗
19. Lee D-D et al (1996) Low-power micro gas sensor. Sens Actuators B Chem 33(1–3):147–15010.1016/0925-4005(96)01822-9 ↗
20. Lentka G (2017) Scalable measurement system for multiple impedance gas sensors. MAPAN 32(3):223–22810.1007/s12647-017-0216-6 ↗
21. Li G-J, Kawi S (1998) Synthesis, characterization and sensing application of novel semiconductor oxides. Talanta 45(4):759–76610.1016/S0039-9140(97)00295-6 ↗
22. Liu S et al (2012) Acetone detection properties of single crystalline tungsten oxide plates synthesized by hydrothermal method using cetyltrimethyl ammonium bromide supermolecular template. Sens Actuators B Chem 162(1):259–26810.1016/j.snb.2011.12.076 ↗
23. Maekawa T et al (2001) Odor identification using a SnO2-based sensor array. Sens Actuators B Chem 80(1):51–5810.1016/S0925-4005(01)00885-1 ↗
24. Mandayo GG, Castano E et al (2003) Strategies to enhance the carbon monoxide sensitivity of tin oxide thin film. Sens Actuators B 95:90–9610.1016/S0925-4005(03)00413-1 ↗
25. Manolis A (1983) The diagnostic potential of breath analysis. Clin Chem 29(1):5–1510.1093/clinchem/29.1.5 ↗
26. Minh TDC, Blake DR, Galassetti PR (2012) The clinical potential of exhaled breath analysis for diabetes mellitus. Diabetes Res Clin Pract 97:19510.1016/j.diabres.2012.02.006 ↗
27. Niranjan RS, Mulla IS (2003) Spin coated tin oxide: a highly sensitive hydrocarbon sensor. Mater Sci Eng B 103(2):103–10710.1016/S0921-5107(03)00154-5 ↗
28. Ozkan E et al (2002) Electrochromic and optical properties of mesoporous tungsten oxide films. Solid State Ion 149(1–2):139–14610.1016/S0167-2738(02)00143-1 ↗
29. Pandya HJ, Chandra S, Vyas AL (2012) Integration of ZnO nanostructures with MEMS for ethanol sensor. Sens Actuators B Chem 161(1):923–92810.1016/j.snb.2011.11.063 ↗
30. Patil PS, Patil PR, Ennaoui EA (2000) Characterization of ultrasonic spray pyrolyzed tungsten oxide thin films. Thin Solid Films 370(1-2):38–4410.1016/S0040-6090(00)00745-8 ↗
31. Prajesh R et al (2014) MEMS based integrated gas sensor for NO2 and NH3. Inst Smart Struct Syst (ISSS) 3(3):1–6
32. Ray SC, Karanjai MK, DasGupta D (1998) Tin dioxide based transparent semiconducting films deposited by the dip-coating technique. Surf Coat Technol 102(1-2):73–8010.1016/S0257-8972(97)00561-6 ↗
33. Righettoni M, Tricoli A (2011) Toward portable breath acetone analysis for diabetes detection. J Breath Res 5(3):03710910.1088/1752-7155/5/3/037109 ↗
34. Righettoni M, Tricoli A, Pratsinis SE (2010) Si: WO3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis. Anal Chem 82(9):3581–358710.1021/ac902695n ↗
35. Rothschild A, Komem Y (2004) The effect of grain size on the sensitivity of nanocrystalline metal-oxide gas sensors. J Appl Phys 95(11):6374–638010.1063/1.1728314 ↗
36. Sachdeva S, Ajay A, Agarwal R (2018) Tungsten oxide thin film characterizations for acetone gas detection. MAPAN 33(1–6):57–6210.1007/s12647-017-0233-5 ↗
37. Sakai G et al (2001) Gas sensing properties of tin oxide thin films fabricated from hydrothermally treated nanoparticles: dependence of CO and H2 response on film thickness. Sensors and Actuators B Chem 77(1–2):116–12110.1016/S0925-4005(01)00682-7 ↗
38. Sberveglieri G et al (1995) WO3 sputtered thin films for NOx monitoring. Sens Actuators B Chem 26(1-3):89–9210.1016/0925-4005(94)01563-W ↗
39. Singh I, Mohan S (2005) 3D Simulations and electro-thermal analysis of micro-hotplate designs using Coventorware for gas sensor applications. In: Proceedings ISSS conference
40. Tatsuyama C, Ichimura S (1976) Electrical and optical properties of GaSe–SnO2 heterojunctions. Jpn J Appl Phys 15(5):84310.1143/JJAP.15.843 ↗
41. Velmathi G, Mohan S (2009) Design, Fabrication and testing of microheater with uniform thermal distribution and low power consumption for gas sensor. In: Proceedings of third national conference on MEMS, smart structures and materials
42. Watson JG et al (2013) Standards and traceability for air quality measurements: flow rates and gaseous pollutants. Mapan 28(3):167–17910.1007/s12647-013-0071-z ↗
43. Yan H et al (1998) Characterizations of SnO2 thin films deposited on Si substrates. Thin Solid Films 326(1-2):88–9110.1016/S0040-6090(98)00530-6 ↗
44. Zakrzewska K (2001) Mixed oxides as gas sensors. Thin Solid Films 391(2):229–23810.1016/S0040-6090(01)00987-7 ↗
45. Ziabari AA, Rozati SM, Bargbidi Z, Kiriakidis G (2012) Characterization and Gas-sensing Performance of Spray Pyrolysed in2O3 thin films: substrate temperature effect. Trans Electr Electron Mater 13(3):111–11510.4313/TEEM.2012.13.3.111 ↗