journal article·2009-10

Multiple conducting polymer microwire sensors

Anirban Chakraborty, Cheng Luo

Microsystem Technologies· Volume 15· Issue 10-11
Publisher page

Abstract

In this work, conducting polymer microwires of three commonly used conducting polymers were fabricated simultaneously on a common substrate using an intermediate-layer lithography (ILL) method. The three conducting polymers under consideration were polypyrrole (PPy), sulphonated polyaniline (SPANI) and poly(3,4-ethylenedioxythiophen)-poly(4-styrenesulphonate) (PEDOT-PSS). The fabricated microwires were implemented as sensing elements in detecting humidity and two organic vapors (i.e., methanol and acetone). The sensitivity of a single PPy microwire was compared with a rectangular PPy film after both were exposed to 45–85% humidity. The microwire sensor, due to its higher surface-to-volume ratio, was found to be more sensitive than the film sensor at low levels of humidity (between 45 and 58%). Beyond 58% humidity, the responses of the film and microwire sensors were similar. Three different sets of conducting polymer microwires (of PPy, SPANI and PEDOT) were then fabricated and employed as sensors to detect methanol, acetone and their mixtures. These microwires exhibited wave-like responses when they were exposed to these targets. The PPy and PEDOT microwires showed higher sensitivities in detecting methanol and acetone, respectively. The SPANI microwires exhibited similar responses in detecting methanol and acetone. The results demonstrate that microwire sensors were more effective than film sensors in detecting little quantities of target molecules. A sensor platform which integrates multiple microwire detectors is promising to detect multiple targets, and it also provides more information in detecting and distinguishing targets.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Chemical Sensor Technologies · Analytical Chemistry and Sensors · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Adhikari B, Majumdar S (2004) Polymers in sensor applications. Prog Polym Sci 29:699–76610.1016/j.progpolymsci.2004.03.002 ↗
2. Ameer Q, Adeloju S (2005) Polypyrrole-based electronic noses for environmental and industrial analysis. Sens Actuators B 106:541–55210.1016/j.snb.2004.07.033 ↗
3. Athawale AA, Kulkarni MV (2000) Polyaniline and its substituted derivatives as sensor for aliphatic alcohols. Sens Actuators B 67:173–17710.1016/S0925-4005(00)00394-4 ↗
4. Bartolini R, Hannan WJ, Karlsons D, Lurie M (1970) Embossed hologram motion pictures for television playback. Appl Opt 9:2283–229010.1364/AO.9.002283 ↗
5. Chakraborty A, Liu X, Parthasarathi G, Luo C (2007) An intermediate-layer lithography method for generating microstructures made of different conducting polymers. Microsyst Technol 13:1175–118410.1007/s00542-006-0321-x ↗
6. Chou SY, Krauss PR, Renstorm PJ (1996) Nanoimprint lithography. J Vac Sci Technol B 14:4129–413310.1116/1.588605 ↗
7. Daoud WA, Xin JH, Szeto YS (2005) Polyethylenedioxythiophene coatings for humidity, temperature and strain sensing polyamide fibers. Sens Actuators B 109:329–33310.1016/j.snb.2004.12.067 ↗
8. de Melo CP, Neto BB, de Lima EG, de Lira LFB, de Souza JEC (2005) Use of conducting polypyrrole blends as gas sensors. Sens Actuators B 109:348–35410.1016/j.snb.2005.01.001 ↗
9. Dhawan SK, Kumar D, Ram MK, Chandra S, Trivedi DC (1997) Application of conducting polyaniline as sensor material for ammonia. Sens Actuators B 40:99–10310.1016/S0925-4005(97)80247-X ↗
10. Gardner JW, Bartlett PN (1994) A brief history of electronic noses. Sens Actuators B 18/19:210–21110.1016/0925-4005(94)87085-3 ↗
11. Hecklele M, Bacher W, Müller KD (1998) Hot embossing-the molding technique for plastic microstructures. Microsyst Technol 4:122–12410.1007/s005420050112 ↗
12. Karyakin AA, Vuki M, Lukachova LV, Karyakina EE, Orlov AV, Karpachova GP, Wang J (1999) Processable polyaniline as an advanced potentiometric pH transducer: application to biosensor. Anal Chem 71:2534–254010.1021/ac981337a ↗
13. Ladawan R, Sirivat A, Schwank J (2004) Electrical conductivity response of polypyrrole to acetone vapor: effect of dopant anions and interaction mechanisms. Synth Met 140:15–2110.1016/S0379-6779(02)01319-X ↗
14. Lancet D, Ben-Arie N (1993) Olfactory receptors. Curr Biol 3:668–67410.1016/0960-9822(93)90064-U ↗
15. Linfords T, Ivaska A (2001) Calcium-selective electrode based on polyaniline functionalized with bis[4-(1, 1, 3, 3-tetramethylbutyl)phenyl]phosphate. Anal Chim Acta 437:171–18210.1016/S0003-2670(01)00996-5 ↗
16. Liu Z, Su Y, Varahramyan (2005) Inkjet-printed silver conductors using silver nitrate ink and their electrical contacts with conducting polymers. Thin Solid Films 478:275–27910.1016/j.tsf.2004.11.077 ↗
17. Luo C, Chakraborty A (2009) Effects of dimensions on the sensitivity of a conducting polymer microwire sensor. Microelectron J 40(6):912–92010.1016/j.mejo.2008.11.064 ↗
18. Luo C, Poddar R, Liu X (2006) Innovative approach for replicating micropatterns in a conducting polymer. J Vac Sci Technol B 24(2):L19–L2210.1116/1.2186341 ↗
19. McGovern ST, Spinks GM, Wallace GG (2005) Micro-humidity sensors based on a processable polyaniline blend. Sens Actuators B 107:657–66510.1016/j.snb.2004.11.046 ↗
20. Munoz BC, Steinthal G, Sunshine G (1999) Conductive polymer-carbon black composites-based sensor array for use in sensor array. Sens Rev 19(4):300–30510.1108/02602289910294745 ↗
21. Patel SV, Jenkins MW, Hughes RC, Yelton WG, Ricco AJ (2000) Differentiation of chemical components in a binary solvent vapor mixture using carbon/polymer composite-based chemiresistor. Anal Chem 72:1532–154210.1021/ac990830z ↗
22. Reed RR (1992) Signaling pathways in odorant detection. Neuron 8:205–20910.1016/0896-6273(92)90287-N ↗
23. Rupprecht L (1999) Conductive polymers and plastics. In: Industrial applications. Plastic design library
24. Sotzing GA, Briglin SM, Grubbs RH, Lewis NS (2000) Preparation and properties of vapor detector arrays formed from Poly(3, 4-ethylenedioxy)thiophene-Poly(styrenesulphonate)/insulating polymer composites. Anal Chem 72:3181–319010.1021/ac991079x ↗
25. Suri K, Annapoorni S, Sarkar AK, Tandon RP (2002) Gas and humidity sensors based on iron oxide-polypyrrole nanocomposites. Sens Actuators B 81:277–28210.1016/S0925-4005(01)00966-2 ↗
26. Torres-Rodriguez LM, Billon M, Roget A, Bidan G (1999) A polypyrrole-biotin based biosensor: elaboration and characterization. Synth Met 102:1328–132910.1016/S0379-6779(98)01053-4 ↗
27. van de Leur RHM, van der Waal A (1999) Gas and vapor detection using polypyrrole. Synth Met 102:1330–133110.1016/S0379-6779(98)01055-8 ↗
28. Yamauchi T, Kojima K, Oshima K, Shimomura M, Miyauchi S (1999) Glucose-sensing characteristics of conducting polymer bound with glucose oxidase. Synth Met 102:132010.1016/S0379-6779(98)01027-3 ↗