Investigation of new micromachined coplanar probe for near-field microwave microscopy
Source abstract
Abstract
The near-field measurement is based generally on the use of purely passive miniature sensors, dedicated to the capture of a component of the electromagnetic field. The performances of probe are characterized by two quantities: the sensitivity and spatial resolution, related to the geometry of the probe. Improve the spatial resolution of a sensor is often at the expense of sensitivity. In this work, we have presented non-conventional planar microwave probe. We achieved These electrical probes, based on a combination of coplanar line and the point effect, using the clean room techniques. The motivation behind the choice of a coplanar line with a pointed end is the fact of having a quasi-TEM propagation mode in order to have the performances of the conventional coaxial probes and secondly to have a compatibility with the integrated circuits for future microwave integrated microscopy. To prevent the oxidation problem, we choose gold as the metal structure. We used an oxidized silicon substrate in order to reduce losses in the silicon. Simulations and measurements results on a micro-strip line have shown that the probe is mainly sensitive to the normal electric field. The estimated sensitivity is 30 µV/(V/m). Using this CPW probe on a precision X–Y scanning table, 2D images of micro-strip line have been successfully constructed, indicated that the ratio of the resolution to the wavelength $$R/\lambda$$ is around $$0.66\times 10-4$$ at 1 GHz.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Near-Field Optical Microscopy · Integrated Circuits and Semiconductor Failure Analysis · Microwave and Dielectric Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Cortes R, Coello V, Arriaga R, Elizondo N (2014) Collection mode near-field scanning microwave microscopy. Optik 125:240010.1016/j.ijleo.2013.10.085 ↗
2. Dutta SK, Vlahacos CP, Steinhauer DE, Thanawalla AS, Feenstra BJ, Wellstood FC, Anlage SM (1999) Imaging microwave electric fields using a near field scanning microwave microscope. Appl Phys Lett 74:15610.1063/1.123137 ↗
3. Gao Y, Wolff I (1997) Measurements of field distributions and scattering parameters in multiconductor structures using an electric field probe: IEEE MTT-S Int. Microw. Symp. Digest, Denver, p 1741
4. Kantor R, Shvets IV (2003) Measurement of electric-field intensities using scanning near-field microwave microscopy. IEE Trans Microw Theory Tech 51:222810.1109/TMTT.2003.818938 ↗
5. Kassing R, Rangelow IW, Oesterschulze E, Stuke M (2003) Sensors for scanning probe microscopy. Appl Phys A 76:90710.1007/s00339-002-1974-7 ↗
6. Marzoug J, Arscott S, El-Fellahi A, Haddadi K, Boyaval C, Lepilliet S, Lasri T, Dambrine G (2016) Optimization of a microelectromechanical systems (MEMS) approach for miniaturized microcantilever-based RF microwave probes. Sens Actuators A Phys 238:5110.1016/j.sna.2015.10.043 ↗
7. Mononobe S (2015) Fabrication of a double-tapered probe with enhanced aspect ratio for near-field scanning optical microscopy. Appl Phys A 121:136510.1007/s00339-015-9499-z ↗
8. Nozokido T, Ishino M, Seto R, Bae J (2015) Contrast analysis of near-field scanning microscopy using a metal slit probe at millimeter wavelengths. J Appl Phys 118:11490510.1063/1.4931149 ↗
9. Obrzut J, Emiroglu C, Kirillov O, Yang Y, Elmquist RE (2016) Surface conductance of graphene from non-contact resonant cavity. Measurement 87:14610.1016/j.measurement.2016.03.020 ↗
10. Oesterschulze E (1998) Novel probes for scanning probe microscopy. Appl Phys A 66:S310.1007/s003390051089 ↗
11. Ramzi MR, Abou-Khousa M, Prayudi I (2017) Near-field microwave imaging using open-ended circular waveguide probes. IEEE Sens J 17:235910.1109/JSEN.2017.2669301 ↗
12. Simons RN (2001) Coplanar waveguide circuits, components, and systems, vol 42. Wiley, New York ISBNs: 0-471-16121-7 (Hardback); 0-471-22475-8 (Electronic)
13. Sun W, Yang Y, Wu Z, Feng T, Zhuang Q, Peng LM, Xu S, Ong CK (2014) Penetrative imaging of sub-surface microstructures with a near-field microwave microscope. J Appl Phys 116:04490410.1063/1.4891215 ↗
14. Synge EH (1928) A suggested method for extending microscopic resolution into the ultra-microscopic region. Philos Mag C 6:35610.1080/14786440808564615 ↗
15. Tabib-Azar M, Wang Y (2004) Design and fabrication of scanning near-field microwave probes compatible with atomic force microscopy to image embedded nanostructures : IEEE Trans. Microw Theory Tech 52:97110.1109/TMTT.2004.823596 ↗
16. Tankielun A, Keller U, Sicard E, Kralicek P, Vrignon B (2006) Electromagnetic near-field scanning for microelectronic test chip investigation. IEEE EMC Society Newsletter, p 68
17. Valiente LA, Gibson AAP, Haigh AD (2004) Tapered coaxial microwave probe sensor. Electron Lett 40:148310.1049/el:20046391 ↗
18. Wei Z, Cui YT, Ma EY, Johnston S, Yang Y, Chen R, Kelly M, Shen ZX, Chen X (2016) Quantitative theory for probe-sample interaction with inhomogeneous perturbation in near-field scanning microwave microscopy. IEEE Trans Microwave Theory Tech 64:140210.1109/TMTT.2016.2537801 ↗