journal article·2014-10

LIGA micro-openings for coherence characterization of X-rays

V. Nazmov, M. Kluge, A. Last, F. Marschall, J. Mohr, H. Vogt, R. Simon

Microsystem Technologies· Volume 20· Issue 10-11
Publisher page

Abstract

Infinitely thin opaque screens serving for diaphragms as defined in the visible-light optics are not feasible for operation with X-ray beams due to their high penetrability. Micro-openings of predicted sidewall shape in a gold layer up to 140 μm thick which would provide low transparency, are proposed. The proposed micro-openings were made using the LIGA technique and tested successfully at photon energies of up to 25 keV. The micro-openings can be used as targets for coherence X-ray pattern or, if long interference tails are avoided by means of the advanced sidewall shape, as X-ray beam collimators.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced X-ray Imaging Techniques · X-ray Spectroscopy and Fluorescence Analysis · Laser-Plasma Interactions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Huttel E, Mueller A-S, Birkel I, Wesolowski P (eds) (2012) ANKA instrumentation book. ANKA Karlsruhe Institute of Technology (KIT), http://www.anka.kit.edu
2. Born M, Wolf E (1986). Principles of optics. Pergamon Press, Oxford
3. Brauer S, Stephenson GB, Sutton M, Brüning R, Dufresne E, Mochrie SGJ, Grübel G, Als-Nielsen J, Abernathy DL (1995) X-ray intensity fluctuation spectroscopy observations of critical dynamics in Fe3Al. Phys Rev Lett 74:2010–2013. doi: 10.1103/PhysRevLett.74.201010.1103/PhysRevLett.74.2010 ↗
4. Cloetens P, Ludwig W, Baruchel J, Van Dyck D, Van Landuyt J, Guigay JP, Schlenker M (1999) Holotomography: ouantitative phase tomography with micrometer resolution using synchrotron radiation X-rays. Appl Phys Lett 75:2912–2914. doi: 10.1063/1.12522510.1063/1.125225 ↗
5. Dierker S, Pindak R, Fleming R, Robinson I, Berman L (1995) X-ray photon correlation spectroscopy study of Brownian motion of gold colloids in glycerol. Phys Rev Lett 75:449–452. doi: 10.1103/PhysRevLett.75.44910.1103/PhysRevLett.75.449 ↗
6. Dufresne EM, Nurushev TS, Clarke R, Dierker S (2002) Concentration fluctuations in the binary mixture hexane-nitrobenzene with static and dynamic X-ray scattering. Phys Rev E Stat Nonlin Soft Matter Phys 65:061507. doi: 10.1103/PhysRevE.65.06150710.1103/PhysRevE.65.061507 ↗
7. Dufresne EM, Dierker SB, Yin Z, Berman L (2009) Development of new apertures for coherent X-ray experiments. J Synchrotron Radiat 16:358–367. doi: 10.1107/S090904950900372010.1107/S0909049509003720 ↗
8. Engelke R, Mathuni J, Ahrens G, Gruetzner G, Bednarzik M, Schondelmaier D, Loechel B (2008) Investigations of SU-8 removal from metallic high aspect ratio microstructures with a novel plasma technique. Microsyst Technol 14:1607–1612. doi: 10.1007/s00542-007-0537-410.1007/s00542-007-0537-4 ↗
9. Haddad WS, McNulty I, Trebes JE, Anderson EH, Levesque RA, Yang L (1994) Ultrahigh-resolution X-ray tomography. Science 266(5188):1213–1215. doi: 10.1126/science.266.5188.121310.1126/science.266.5188.1213 ↗
10. Leitenberger W, Kuznetsov S, Snigirev A (2001) Interferometric measurements with hard X-rays using a double slit. Opt Comm 191:91–96. doi: 10.1016/S0030-4018(01)01104-X10.1016/S0030-4018(01)01104-X ↗
11. Livet F (2007) Diffraction with a coherent X-ray beam: dynamics and imaging. Acta Crystallogr A A63:87–107. doi: 10.1107/S010876730605570X10.1107/S010876730605570X ↗
12. Mendez OM, Cadilhac M, Petit R (1983) Diffraction of a two-dimensional electromagnetic beam wave by a thick slit pierced in a perfectly conducting screen. J Opt Soc Am 73:328–331. doi: 10.1364/JOSA.73.00032810.1364/JOSA.73.000328 ↗
13. Nazmov VP, Mezentseva LA, Pindyurin VF, Petrov VV, Yakovleva EN (2000) Modelling and manufacture of regular microstructures with high aspect ratio in acrylic plastic. Nucl Instr Meth PhysRes A 448:493–496. doi: 10.1016/S0168-9002(00)00238-210.1016/S0168-9002(00)00238-2 ↗
14. Nazmov V, Reznikova E, Somogyi A, Mohr J, Saile V (2004) Planar sets of cross X-ray refractive lenses from SU-8 polymer. Proc SPIE 5539:235–243. doi: 10.1117/12.56261510.1117/12.562615 ↗
15. Paterson D, Allman BE, McMahon PJ, Lin J, Moldovan N, Nugent KA, McNulty I et al (2001) Spatial coherence measurement of X-ray undulator radiation. Opt Comm 195:79–84. doi: 10.1364/JOSAA.23.00177910.1016/S0030-4018(01)01276-7 ↗
16. Polack F, Joyeux D, Svatos J, Phalippou D (1995) Application of wavefront division interferometers in soft X-rays. Rev Sci Instrum 66:2180–2183. doi: 10.1063/1.114569810.1063/1.1145698 ↗
17. Robinson I, Harder R (2009) Coherent X-ray diffraction imaging of strain at the nanoscale. Nat Mater 8:291–298. doi: 10.1038/nmat240010.1038/nmat2400 ↗
18. Takayama Y, Hatano T, Miyahara T, Okamoto W (1998a) Relationship between spatial coherence of synchrotron radiation and emittance. J Synchrotron Radiat 5:1187–1194. doi: 10.1107/S090904959701975410.1107/S0909049597019754 ↗
19. Takayama Y, Tai RZ, Hatano T, Miyahara T, Okamoto W, Kagoshima Y (1998b) Measurement of the coherence of synchrotron radiation. J Synchrotron Radiat 5:456–458. doi: 10.1107/S090904959701301010.1107/S0909049597013010 ↗