journal article·2017-10

Effects of an additional air chamber on the sensitivity of a capacitive pressure sensor

Jaehyuk Choi, Bumkyoo Choi

Microsystem Technologies· Volume 23· Issue 10
Publisher page

Abstract

This study demonstrates the effect of an additional air chamber on the sensitivity of an air-sealed capacitive pressure sensor. This effect is investigated by theoretical analysis, finite element analysis, and experimental validation. First, the variation in sensitivity of the capacitive pressure sensor with air chambers of various volumes was investigated by an analytical method as a theoretical approach and by FEM simulation. The results showed that the sensitivity of an air-sealed capacitive pressure sensor with a flexible diaphragm could be enhanced by adopting an additional air chamber. In this process, the variation in the ambient temperature was also considered. Experimental validation was conducted by fabricating a sensor to consider the previous result. The results of the experimental validation of the air-sealed capacitive pressure sensor with natural rubber latex (NRL) diaphragm showed that the sensitivity increased more than 15-fold by adopting the additional air chamber compared to the NRL sensor without the air chamber. Consequently, the NRL sensor with the additional air chamber measured a pressure sensitivity of 8986 ppm/kPa and a pressure responsivity of 1.391 MHz/kPa in the applied pressure range of 1–10 kPa. Finally, the effect of the variation in ambient temperature on the sensitivity of an air-sealed capacitive pressure sensor was measured and compared with the theoretical and FEM simulation results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Advanced MEMS and NEMS Technologies · Sensor Technology and Measurement Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Akar O, Akin T, Najafi K (2001) A wireless batch sealed absolute capacitive pressure sensor. Sens Actuators A 95:29–3810.1016/S0924-4247(01)00753-1 ↗
2. Chang S-P, Allen MG (2004) Capacitive pressure sensors with stainless steel diaphragm and substrate. J Micromech Microeng 14:61210.1088/0960-1317/14/4/023 ↗
3. Chavan AV, Wise KD (2001) Batch-processed vacuum-sealed capacitive pressure sensors. J Microelectromech Syst 10:580–58810.1109/84.967381 ↗
4. Chen P-J, Rodger DC, Saati S, Humayun MS, Tai Y-C (2008) Microfabricated implantable parylene-based wireless passive intraocular pressure sensors. Microelectromechanical Systems, Journal of 17:1342–135110.1109/JMEMS.2008.2004945 ↗
5. Chen P-J, Saati S, Varma R, Humayun MS, Tai Y-C (2010) Wireless intraocular pressure sensing using microfabricated minimally invasive flexible-coiled LC sensor implant. J Microelectromech Syst 19:721–73410.1109/JMEMS.2010.2049825 ↗
6. Daigle M, Corcos J, Wu K (2007) An analytical solution to circular touch mode capacitor. Sens J IEEE 7:502–50510.1109/JSEN.2007.891996 ↗
7. DeHennis A, Wise KD (2002) A double-sided single-chip wireless pressure sensor in Micro Electro Mechanical Systems. Fifteenth IEEE Int Conf 2002:252–255
8. Hao X, Maenaka K, Takao H, Higuchi K (2014) An analytical thermal-structural model of a gas-sealed capacitive pressure sensor with a mechanical temperature compensation structure. Sens Actuators A 205:92–10210.1016/j.sna.2013.10.029 ↗
9. He F, Huang Q-A, Qin M (2007) A silicon directly bonded capacitive absolute pressure sensor. Sens Actuators A 135:507–51410.1016/j.sna.2006.09.022 ↗
10. Lee HY, Choi B (2015) Theoretical and experimental investigation of the trapped air effect on air-sealed capacitive pressure sensor. Sens Actuators A 221:104–11410.1016/j.sna.2014.11.002 ↗
11. Park J, Gianchandani Y (2000) A capacitive absolute-pressure sensor with external pick-off electrodes. J Micromech Microeng 10:52810.1088/0960-1317/10/4/307 ↗
12. Puers R (1993) Capacitive sensors: when and how to use them. Sens Actuators A 37:93–10510.1016/0924-4247(93)80019-D ↗
13. Radosavljević GJ, Zivanov LD, Smetana W, Marić AM, Unger M, Nađ LF (2009) A wireless embedded resonant pressure sensor fabricated in the standard LTCC technology. Sens J IEEE 9:1956–196210.1109/JSEN.2009.2030974 ↗
14. Smith MS, Bowman L, Meindl JD (1986) Analysis, design, and performance of a capacitive pressure sensor IC. IEEE Trans Biomed Eng 33:163–17410.1109/TBME.1986.325849 ↗
15. Timoshenko S, Woinowsky-Krieger S (1959) Theory of plates and shells vol. 2. McGraw-hill, New York