Numerical study on micromixers with Wall-Fractal structure
Source abstract
Abstract
The ability for low reagent consumption and minimum waste production in a miniaturised system has generated great interest in the green chemistry field and medical testing. Microfluidic technology is the trend of miniaturization of testing instruments. Passive micromixer in particular has attracted much attention over active micromixers due to their fabrication and operation simplicity. This article presents a Wall-Fractal micromixer, in which, the effect of fractal structure on mixing efficiency was studied by numerical simulation. On the basis of fractal principle, the study focus on the Primary Wall-Fractal (PWF) and Secondary Wall-Fractal (SWF) in the single wall and double walls on the mixing efficiency. Under different numbers of Reynolds (Res), the efficiency of SWF was better than that of PWF. With the distance A-B increasing, it does not contribute to improve the mixing efficiency. Effected by the symmetrically Wall-Fractal that the mixing efficiency at Re = 0.05 and Re = 100 reach up to 95% in outlet. Because of its high mixing efficiency, Wall-Fractal micromixer will have broad application prospects.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Innovative Microfluidic and Catalytic Techniques Innovation · Electrowetting and Microfluidic Technologies · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Barz DPJ, Zadeh HF, Ehrhard P (2007) Measurements and simulations of the flow field in an electrically excited meander micromixer. Particle image velocimetry. Springer, Berlin, pp 1–18
2. Cao Q, Han X, Li L (2015) An active microfluidic mixer utilizing a hybrid gradient magnetic field. Int J Appl Electromagn Mech 47(3):583–59210.3233/JAE-140057 ↗
3. Chen X, Li T (2016) A novel design for passive misscromixers based on topology optimization method. Biomed Microdevice 18(4):1–1510.1007/s10544-016-0082-y ↗
4. Chen X, Shen J (2017) Numerical and experimental investigation on splitting-and-recombination micromixer with E-shape mixing units. Microsyst Technol 23(10):4671–467710.1007/s00542-016-3208-5 ↗
5. Chen X, Wang X (2015) Optimized modular design and experiment for staggered herringbone chaotic micromixer. Int J Chem React Eng 13(3):305–30910.1515/ijcre-2014-0123 ↗
6. Chen X, Liu C, Xu Z, Liu J, Du L (2012) Macro-micro modeling design in system-level and experiment for a micromixer. Anal Methods 4(8):2334–234010.1039/c2ay25263e ↗
7. Chen X, Li T, Zeng H et al (2016a) Numerical and experimental investigation on micromixers with serpentine microchannels. Int J Heat Mass Transf 98:131–14010.1016/j.ijheatmasstransfer.2016.03.041 ↗
8. Chen X, Shen J, Zhou M (2016b) Rapid fabrication of a four-layer PMMA-based microfluidic chip using CO2-laser micromachining and thermal bonding. J Micromech Microeng 26(10):10700110.1088/0960-1317/26/10/107001 ↗
9. Chen X, Li T, Hu Z et al (2017) Using orthogonal experimental method optimizing surface quality of CO2 laser cutting process for PMMA microchannels. Int J Adv Manuf Technol 88(9–12):2727–273310.1007/s00170-016-8887-7 ↗
10. Choi E, Kwon K, Lee SJ et al (2015) Non-equilibrium electrokinetic micromixer with 3D nanochannel networks. Lab Chip 15(8):1794–179810.1039/C4LC01435A ↗
11. Chung C, Chen YJ, Chen PC et al (2015) Fabrication of PDMS passive micromixer by lost-wax casting. Int J Precis Eng Manuf 16(9):2033–203910.1007/s12541-015-0264-1 ↗
12. Cortes-Quiroz CA, Azarbadegan A, Moeendarbary E (2010) An efficient passive planar micromixer with fin-shaped baffles in the tee channel for wide Reynolds number flow range. World Acad Sci Eng Technol 61:170–175
13. Dixon C, Ng AHC, Fobel R et al (2016) An inkjet printed, roll-coated digital microfluidic device for inexpensive, miniaturized diagnostic assays. Lab Chip 16(23):4560–456810.1039/C6LC01064D ↗
14. Du Y, Zhang Z, Yim CH, Lin M, Cao X (2010) A simplified design of the staggered herringbone micromixer for practical applications. Biomicrofluidics 4(2):02410510.1063/1.3427240 ↗
15. Duan X, Feng X, Yang C et al (2016) Numerical simulation of micro-mixing in stirred reactors using the engulfment model coupled with CFD. Chem Eng Sci 140:179–18810.1016/j.ces.2015.10.017 ↗
16. Fitzgerald DA (2001) Making every nanoliter count: microfluidics devices promise great potential in small packages (Lab Consumer). The Scientist 15(21):22–25
17. Fu LM, Fang WC, Hou HH, Wang YN, Hong TF (2014a) Rapid vortex microfluidic mixer utilizing double-heart chamber. Chem Eng J 249:246–25110.1016/j.cej.2014.03.037 ↗
18. Fu LM, Fang WC, Hou HH, Wang YN, Hong TF (2014b) Rapid vortex microfluidic mixer utilizing double-heart chamber. Chem Eng J 249:246–25110.1016/j.cej.2014.03.037 ↗
19. Guo MT, Rotem A, Heyman JA et al (2012) Droplet microfluidics for high-throughput biological assays. Lab Chip 12(12):2146–215510.1039/c2lc21147e ↗
20. Jain M, Rao A, Nandakumar K (2013) Numerical study on shape optimization of groove micromixers. Microfluid Nanofluid 15(5):689–69910.1007/s10404-013-1169-x ↗
21. Kakavandi FH, Rahimi M, Jafari O et al (2016) Liquid–liquid two-phase mass transfer in T-type micromixers with different junctions and cylindrical pits. Chem Eng Process 107:58–6710.1016/j.cep.2016.06.011 ↗
22. Liu K, Yang Q, Chen F, Zhao Y, Meng X, Shan C, Li Y (2015) Design and analysis of the cross-linked dual helical micromixer for rapid mixing at low Reynolds numbers. Microfluid Nanofluid 19(1):169–18010.1007/s10404-015-1558-4 ↗
23. Manz A, Effenhauser CS, Burggraf N et al (1994) Electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems. J Micromech Microeng 4(4):25710.1088/0960-1317/4/4/010 ↗
24. Ríos Á, Zougagh M (2015) Modern qualitative analysis by miniaturized and microfluidic systems. TrAC Trends Anal Chem 69:105–11310.1016/j.trac.2015.04.003 ↗
25. Ryu G, Huang J, Hofmann O et al (2011) Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip. Lab Chip 11(9):1664–167010.1039/c0lc00586j ↗
26. Srinivasan V, Pamula VK, Fair RB (2004) An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. Lab Chip 4(4):310–31510.1039/b403341h ↗
27. Vasilakis N, Moschou D, Prodromakis T (2016) Computationally efficient concentration-based model for accurate evaluation of T-junction inlet staggered herringbone micromixers. Micro Nano Lett 11(5):236–23910.1049/mnl.2015.0239 ↗
28. Viktorov V, Nimafar M (2013) A novel generation of 3D SAR-based passive micromixer: efficient mixing and low pressure drop at a low Reynolds number. J Micromech Microeng 23(5):05502310.1088/0960-1317/23/5/055023 ↗
29. Vozzi G, Mazzei D, Tirella A, Vozzi F, Ahluwalia A (2010) Finite element modelling and design of a concentration gradient generating bioreactor: application to biological pattern formation and toxicology. Toxicol In Vitro 24(6):1828–183710.1016/j.tiv.2010.05.010 ↗
30. Weigl BH, Bardell RL, Cabrera CR (2003) Lab-on-a-chip for drug development. Adv Drug Deliv Rev 55(3):349–37710.1016/S0169-409X(02)00223-5 ↗