A new blood flow volume sensor with embedded estimation of SpO2 to maximize its accuracy
Source abstract
Abstract
A new portable blood flow volume (BFV) sensor is developed from the function of estimating oxygen saturation (SpO2) implemented inherently to maximize the accuracy of predicting BFV. The sensor is designed to estimate BFV in high accuracy at the arteriovenous fistula (AVF) of a hemodialysis (HD) patient based on a built artificial neural network (ANN). The BFVs measured by the proposed sensor would help greatly evaluate the AVF complications at early stage, such as infection, bleeding, stenosis, and vascular calcification, while AVFs are under long-time usage. The sensor module consists of LEDs/PDs, readout circuitry and algorithm to estimate BFV. The oxygen saturation (SpO2) is also estimated using the same hardware to serve as one of input features for the aforementioned ANN for maximize the accuracy in BFV. With using the hardware, oxygen saturation’s algorithm is built and implemented with the mean deviation (MD) and standard deviation (SD) adapted FDA standard, which is MD ∓ 1.96SD = 0.024% ∓ 1.772% < 5%. Besides, the BFV ground-truth data are obtained from a transonic HD03 dilution machine for calibrating the ANN. The accuracy in estimating BFV with and without estimating SpO2 are compared, which correspond to R2 = 0. 94,517, root mean square error = 92.199 ml/min and R2 = 0.87145, root mean square error = 141.015 ml/min, respectively. Besides, another neural network model is implemented with fixing value of an input feature of SpO2, the ANN model’s correlation reaches only 0.1554, while the related root mean square error is 493.2442 ml/min. Therefore, the results validate clearly the necessity of the inherent estimation on SpO2.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Electrical and Bioimpedance Tomography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Bessems D, Rutten M, Vsse FVD (2007) A wave propagation model of blood flow in large vessels using an approximate velocity profile function. J Fluid Mech 580:145–16810.1017/S0022112007005344 ↗
2. Cai B, Jiang X (2014) A novel artificial neural network method for biomedical prediction based on matrix pseudo-inversion. J Biomed Inform 48:114–12110.1016/j.jbi.2013.12.009 ↗
3. Chiang PY, Chao PC-P, Tarng DC, Yang CY (2017) A novel wireless photoplethysmography blood flow volume sensor for assessing arteriovenous fistula of hemodialysis patients. IEEE Trans Ind Electron 64:9626–963510.1109/TIE.2017.2701780 ↗
4. da Silva FAM, Kruger MAV, de Pereira WCA (2014) Continuous flow phantom for the calibration of an ultrasonic transit-time flowmeter. Res Biomed Eng 30:03–10
5. Global, regional, and national burden of chronic kidney disease, 1990–2017: a systematic analysis for the global burden of disease study 2017. https://www.thelancet.com/article/S0140-6736(20)30045-3/fulltext
6. Ingle JD, Crouch SR (1988) Spectrochemical analysis. Prentice Hall, Englewood Cliffs
7. Kao YH, Chao PCP, Wey CL (2018) Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter. Microsyst Technol 24:4621–462210.1007/s00542-018-3877-3 ↗
8. Krivitski NM (1995) Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 48:244–25010.1038/ki.1995.290 ↗
9. Lee C, Shin HS, Lee M (2011) Relations between ac–dc components and optical path length in photoplethysmography. J Biomed Opt 16:1–10
10. Mukherjee R, Dubey S, Gupta B, Chakravarty T (2016) Bio-optical modeling of human skin to eliminate the skin structure variability in blood pressure measurement. In: Conference on IEEE advances in electrical, electronics, information, communication and bio-informatics (AEEICB), pp 450–45410.1109/AEEICB.2016.7538329 ↗
11. Näslund J, Pettersson J, Lundeberg T, Linnarsson D, Lindberg L-G (2006) Non-invasive continuous estimation of blood flow changes in human patellar bone. Med Biol Eng Comput 44:501–50910.1007/s11517-006-0070-0 ↗
12. National Kidney Foundation (2006) KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: hemodialysis adequacy peritoneal dialysis adequacy and vascular access. Am J Kidney Dis 48(suppl 1):S1–S322
13. Orozco L (2013) Programmable-gain transimpedance amplifiers maximize dynamic range in spectroscopy systems. Analog Dialogue 47:1–5
14. Reisner A, Shaltis PA, McCombie D, Asada HH (2008) Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology 108:950–95810.1097/ALN.0b013e31816c89e1 ↗
15. Rybynok VO, Kyriacou PA (2010) Beer–Lambert law along non-linear mean light pathways for the rational analysis of photoplethysmography. J Phys Conf Ser 238(1): 01206110.1088/1742-6596/238/1/012061 ↗
16. Sallomi AH, Ahmed S (2016) Multi-layer feed forward neural network application in adaptive beamforming of smart antenna system. In: 2016 Al-Sadeq international conference on multidisciplinary in IT and communication science and applications (AIC-MITCSA). IEEE10.1109/AIC-MITCSA.2016.7759925 ↗
17. Tamura T, Maeda Y, Sekine M, Yoshida M (2014) Wearable photoplethysmographic sensors—past and present. Electronics 3:282–30210.3390/electronics3020282 ↗
18. Teng XF, Zhang YT (2004) The effect of contacting force on photoplethysmographic signals. Physiol Meas 25:1323–133510.1088/0967-3334/25/5/020 ↗
19. Tessitore N, Bedogna V, Gammaro L, Lipari G, Poli A, Baggio E, Firpo M, Morana G, Mansueto G, Maschio G (2003) Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis. Am J Kidney Dis 42:331–34110.1016/S0272-6386(03)00659-0 ↗
20. Venketesu K (2015) Blood flow analysis using ultrasound doppler technique. IOSR J Electron Commun Eng 10:31–35
21. Whittier WL (2009) Surveillance of hemodialysis vascular access. Semin Intervent Radiol 26:130–13810.1055/s-0029-1222457 ↗
22. Wilhelm K-P, Elsner P, Berardesca E, Maibach HI (2006) Bioengineering of the skin: skin imaging and analysis. CRC Press, Boca Raton10.3109/9781420005516 ↗
23. Zeraati A, Mousavi SSB, Mousavi MB (2013) A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis. Nephro-Urol Mon 5:728–73210.5812/numonthly.6689 ↗
24. https://www.transonic.com/product/hd03-hemodialysis-monitor/
25. http://www.rossmax.com/downloads/Epaper/Epaper_SA210_EN.pdf
26. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/pulse-oximeters-premarket-notification-submissions-510ks-guidance-industry-and-food-and-drug
27. https://www.openstax.org/books/anatomy-and-physiology/pages/1-introduction