This paper reports a new technique of fabricating polystyrene microlenses with both convex and concave profiles that are integrated in polymer-based microfluidic system. The polystyrene microlenses, or microlens array, are fabricated using the free-surface thermal compression molding method. The laser fabricated poly(methyl methacrylate) (PMMA) sheet is used as the mold for the thermal compression molding process. With different surface treatment methods of the PMMA mold, microlenses with either convex or concave profiles could be achieved during the thermal molding process. By integrating the microlenses in the microfluidic systems, observing the flow inside the microchannels is easier. This new technique is rapid, low cost, and it does not require cleanroom facilities. Microlenses with both convex and concave profiles can be easily fabricated and integrated in microfluidic system with this technique.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Innovative Microfluidic and Catalytic Techniques Innovation · Advanced optical system design · Nanofabrication and Lithography Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Abdelgawad M, Watson MWL, Wheeler AR (2009) Hybrid microfluidics: a digital-to-channel interface for in-line sample processing and chemical separations. Lab Chip 9(8):1046–1051. doi: 10.1039/b820682a10.1039/b820682a ↗
2. Carter JC, Alvis RM, Brown SB, Langry KC, Wilson TS, McBride MT, Myrick ML, Cox WR, Grove ME, Colston BW (2006) Fabricating optical fiber imaging sensors using inkjet printing technology: a pH sensor proof-of-concept. Biosens Bioelectron 21(7):1359–1364. doi: 10.1016/j.bios.2005.06.00610.1016/j.bios.2005.06.006 ↗
3. Domachuk P, Tsioris K, Omenetto FG, Kaplan DL (2010) Bio-microfluidics: biomaterials and Biomimetic Designs. Adv Mater 22(2):249–260. doi: 10.1002/adma.20090082110.1002/adma.200900821 ↗
4. Edwards CA, Presby HM, Dragone C (1993) Ideal microlenses for laser to fiber coupling. J Lightwave Technol 11(2):610.1109/50.212535 ↗
5. Etoh TG, Poggemann D (2003) An image sensor which captures 100 consecutive frames at 1000000 frames/s. IEEE Trans Electron Devices 50(1):7
6. Fakhfouri V, Cantale N, Mermoud G, Kim JY, Boiko D, Charbon E, Martinoli A, Brugger J (2008) Inkjet printing of SU-8 for polymer-based MEMS a case study for microlenses. In: Micro electro mechanical systems, 2008. MEMS 2008. IEEE 21st international conference on, 13–17 Jan. 2008. pp 407–410. doi: 10.1109/memsys.2008.444367910.1109/MEMSYS.2008.4443679 ↗
7. Fan YQ, Li HW, Foulds IG (2011) Fabrication of microlens and microlens array on polystyrene using CO2 laser. Adv Mater Res 403–408:3350–3353. doi: 10.4028/www.scientific.net/AMR.403-408.335010.4028/www.scientific.net/AMR.403-408.3350 ↗
8. Fan Y, Li H, Conchouso D, Foulds IG (2013a) Simulation and fabrication of integrated polystyrene microlens in microfluidic system. SPIE Microtechnologies 8763:876318. doi: 10.1117/12.201550910.1117/12.2015509 ↗
9. Fan Y, Li H, Yi Y, Foulds I (2013b) PMMA to Polystyrene bonding for polymer based microfluidic systems. Microsyst Technol:1–6. doi: 10.1007/s00542-013-1778-z10.1007/s00542-013-1778-z ↗
10. Gunther A, Jensen KF (2006) Multiphase microfluidics: from flow characteristics to chemical and materials synthesis. Lab Chip 6(12):1487–1503. doi: 10.1039/b609851g10.1039/B609851G ↗
11. Iga K, Oikawa M, Misawa S, Banno J, Kokubun Y (1982) Stacked planar optics: an application of the planar microlens. Appl Opt 21(19):5
12. Kunnavakkam MV, Houlihan FM, Schlax M, Liddle JA, Kolodner P, Nalamasu O, Rogers JA (2003) Low-cost, low-loss microlens arrays fabricated by soft-lithography replication process. Appl Phys Lett 82(8):1152. doi: 10.1063/1.155569410.1063/1.1555694 ↗
13. Lim CS, Hong MH, Kumar AS, Rahman M, Liu XD (2006) Fabrication of concave micro lens array using laser patterning and isotropic etching. Int J Mach Tools Manuf 46(5):552–558. doi: 10.1016/j.ijmachtools.2005.06.00410.1016/j.ijmachtools.2005.06.004 ↗
14. Mihailov S, Lazare S (1993) Fabrication of refractive microlens arrays by excimer laser ablation of amorphous Teflon. Appl Opt 32(31):6211–621810.1364/AO.32.006211 ↗
15. O’Neill FT, Sheridan JT (2002) Photoresist reflow method of microlens production Part I: background and experiments. Optik Int J Light Electron Optics 113(9):391–404. doi: 10.1078/0030-4026-0018610.1078/0030-4026-00186 ↗
16. Partridge RH (1967) Vacuum-ultraviolet absorption spectrum of polystyrene. J Chem Phys 47(10):4223–422710.1063/1.1701603 ↗
17. Yabu H, Shimomura M (2005) Simple fabrication of micro lens arrays. Langmuir 21(5):1709–1711. doi: 10.1021/la046996z10.1021/la046996z ↗
18. Yang H, Chao C-K, Wei M-K, Lin C-P (2004) High fill-factor microlens array mold insert fabrication using a thermal reflow process. J Micromech Microeng 14(8):1197–1204. doi: 10.1088/0960-1317/14/8/01210.1088/0960-1317/14/8/012 ↗
19. Yi C, Li C-W, Ji S, Yang M (2006) Microfluidics technology for manipulation and analysis of biological cells. Anal Chim Acta 560 (1–2):1–23. doi: http://dx.doi.org/10.1016/j.aca.2005.12.03710.1016/j.aca.2005.12.037 ↗