Spectroscopic Properties Unique to Nano-Emitters
Source abstract
Abstract
The spectral position of light emission from an individual carbon nanotube is shown to depend on the location of the nanotube within the focal spot, while no such effect is present for macroscopic emitters. In addition, in contrast to macroscopic emitters, the measured line width from the nanotube emitter is independent of spectrometer entrance slit width. The effects are general for any nanoscale optical emitter with at least one dimension smaller than the optical diffraction limit.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Carbon Nanotubes in Composites · Mechanical and Optical Resonators · Nanowire Synthesis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics, 590 Commonwealth Avenue, and Department of Electrical and Computer Engineering and The Boston University Photonics Center, 8 Saint Mary’s Street, Boston University, Boston, Massachusetts 02215, and CEMES UPR-CNRS, 29 rue Jeanne Marvig, Université Toulouse, 31055 Toulouse, France
References (31)
Show source-provided references
1. Empedocles S. · Acc. Chem. Res. · 1999 · 32 · 38910.1021/ar9501939 ↗
2. Alen B. · Appl. Phys. Lett. · 2003 · 83 · 223510.1063/1.1609243 ↗
3. Vamivakas, A. N.; Zhao, Y.; Lu, C.Y.; Atature, M.arXiv:cond-mat/0806.3707.
4. Bayer M. · Phys. Rev. B · 2002 · 65 · 12130910.1103/PhysRevB.65.121309 ↗
5. Findeis F. · Phys. Rev. B · 2001 · 63 · 12130910.1103/PhysRevB.63.121309 ↗
6. Zrenner A. · Physica B · 1998 · 256 · 30010.1016/S0921-4526(98)00480-3 ↗
7. Cronin S. B. · Phys. Rev. Lett. · 2006 · 96 · 12740310.1103/PhysRevLett.96.127403 ↗
8. Cronin S. B. · Phys. Rev. B · 2005 · 72 · 03542510.1103/PhysRevB.72.035425 ↗
9. Cronin S. B. · Phys. Rev. Lett. · 2004 · 93 · 16740110.1103/PhysRevLett.93.167401 ↗
10. Lucas M. · Phys. Rev. B · 2004 · 69 · 08540510.1103/PhysRevB.69.085405 ↗
11. Walsh A. G. · Nano Lett. · 2007 · 7 · 148510.1021/nl070193p ↗
12. Walsh A. G. · Physica E · 2008 · 40 · 237510.1016/j.physe.2007.07.007 ↗
13. Arnold M. S. · Nat. Nanotechnol. · 2006 · 1 · 6010.1038/nnano.2006.52 ↗
14. Zheng M. · Science · 2003 · 302 · 154510.1126/science.1091911 ↗
15. Reich S. · 2004
16. We have found the nano-emitter to be helpful in correcting alignment issues and in diagnosing chromatic aberration effects arising from the beam waist not falling precisely at the plane of the slit. That is, the slit can begin to act as the system aperture stop.
17. http://www.jobinyvon.com/SiteResources/Data/Templates/1divisional.asp?DocID=566&v1ID=&lang.
18. Wang F. · Phys. Rev. Lett. · 2006 · 96 · 16740110.1103/PhysRevLett.96.167401 ↗
19. See Newport application note athttp://www.newport.com/file_store/Optics_and_Mechanics/AppsNote28.pdf.
20. Wolf E. · Phys. Rev. Lett. · 1987 · 58 · 264610.1103/PhysRevLett.58.2646 ↗
21. Gbur G. · Phys. Rev. Lett. · 2002 · 88 · 01390110.1103/PhysRevLett.88.013901 ↗
22. Jorio A. · Phys. Rev. B · 2002 · 65 · 12140210.1103/PhysRevB.65.121402 ↗
23. The beam profile was determined by recording the power as a razor was advanced through the beam by micrometer screw, fitting the resulting curve with the error function, and taking the derivative. The results indicate an incident beam with a nearly perfect Gaussian profile. FWHM = 1.46 mm and objective back focal openings are 3.6 mm and 4 mm for the 100× and 50× objectives, respectively.
24. Vamivakas A. N. · Opt. Lett. · 2007 · 32 · 97010.1364/OL.32.000970 ↗
25. Rao A. M. · Nature · 1997 · 388 · 25710.1038/40827 ↗
26. Tsang J. C. · Nat. Nanotechnol. · 2007 · 2 · 72510.1038/nnano.2007.321 ↗
27. Novotny L. · 200610.1017/CBO9780511813535 ↗
28. Hecht E. · 2002
29. In most systems, the contribution from the grating resolution can be ignored. Here, Δσgcontributes <2% of the instrumental broadening.
30. Here we use the Gaussian form to simply illuminate the different contributions to the line width even though the slit and the pixel have a rectangular form. The result in Figure4is obtained from a proper convolution.
31. When the slit starts to clip the diffraction-limited spot size, the line-width contribution from the instrument response decreases. However, the system parameters are often chosen so that the pixel size is approximately commensurate with the diffraction-limited spot size at the slit making this effect moot.