journal article·2022-11-24Open access

Micro and Nano Interdigitated Electrode Array (IDEA)-Based MEMS/NEMS as Electrochemical Transducers: A Review

Elyana Kosri, Fatimah Ibrahim, Aung Thiha, Marc Madou

Nanomaterials· Volume 12· Issue 23

Abstract

Micro and nano interdigitated electrode array (µ/n-IDEA) configurations are prominent working electrodes in the fabrication of electrochemical sensors/biosensors, as their design benefits sensor achievement. This paper reviews µ/n-IDEA as working electrodes in four-electrode electrochemical sensors in terms of two-dimensional (2D) planar IDEA and three-dimensional (3D) IDEA configurations using carbon or metal as the starting materials. In this regard, the enhancement of IDEAs-based biosensors focuses on controlling the width and gap measurements between the adjacent fingers and increases the IDEA’s height. Several distinctive methods used to expand the surface area of 3D IDEAs, such as a unique 3D IDEA design, integration of mesh, microchannel, vertically aligned carbon nanotubes (VACNT), and nanoparticles, are demonstrated and discussed. More notably, the conventional four-electrode system, consisting of reference and counter electrodes will be compared to the highly novel two-electrode system that adopts IDEA’s shape. Compared to the 2D planar IDEA, the expansion of the surface area in 3D IDEAs demonstrated significant changes in the performance of electrochemical sensors. Furthermore, the challenges faced by current IDEAs-based electrochemical biosensors and their potential solutions for future directions are presented herein.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical Analysis and Applications · Nanopore and Nanochannel Transport Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia

Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia

Centre of Printable Electronics, Universiti Malaya, Kuala Lumpur 50603, Malaysia

Department of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA

School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey 64849, NL, Mexico

Academia Mexicana de Ciencias, Ciudad de México 14400, CDMX, Mexico

Funding

Ministry of Science and Technology (MOSTI) · Ministry of Higher Education (MOHE) · Universiti Malaya

References (100+)

Show source-provided references
1. Gonsalves, K.E., Laurencin, C.L., Halberstadt, C.R., and Nair, L.S. (2008). Clinical Applications of Micro- and Nanoscale Biosensors. Biomedical Nanostructures, John Wiley & Sons, Inc.10.1002/9780470185834 ↗
2. Zourob, M. (2010). Principles of biomolecular recognition. Recognition Receptors in Biosensors, Springer.10.1007/978-1-4419-0919-0 ↗
3. Lowe, C.R. (2008). Overview of Biosensor and Bioarray Technologies. Handbook of Biosensors and Biochips, Wiley.10.1002/9780470061565.hbb003 ↗
4. Advances in biosensors: Principle, architecture and applications10.1016/j.jab.2013.02.001 ↗
5. An overview of foodborne pathogen detection: In the perspective of biosensors10.1016/j.biotechadv.2009.12.004 ↗
6. Carbon Nanomaterial-Based Electrochemical Biosensors for Foodborne Bacterial Detection10.1080/10408347.2018.1561243 ↗
7. Mediated biosensors10.1016/S0956-5663(01)00313-X ↗
8. Biosensors and nanomaterials and their application for mycotoxin determination10.3920/WMJ2011.1318 ↗
9. Electrochemical sensor for indirect detection of bacterial population10.1016/j.snb.2004.04.022 ↗
10. Electrochemical biosensors10.1039/b714449k ↗
11. Novel impedimetric aptasensor for label-free detection of Escherichia coli O157:H710.1016/j.snb.2017.09.121 ↗
12. Impedimetric transducers based on interdigitated electrode arrays for bacterial detection—A review10.1016/j.aca.2019.09.026 ↗
13. Highly selective detection of Escherichia coli O157:H7 based on micro-gapped interdigitated electrode arrays10.1080/13102818.2017.1335178 ↗
14. Label-Free Detection of Bacteria by Electrochemical Impedance Spectroscopy: Comparison to Surface Plasmon Resonance10.1021/ac070085n ↗
15. Electrochemical Genosensor To Detect Pathogenic Bacteria (Escherichia coli O157:H7) As Applied in Real Food Samples (Fresh Beef) To Improve Food Safety and Quality Control10.1021/acs.jafc.5b00675 ↗
16. Electrochemical biosensors—Sensor principles and architectures10.3390/s80314000 ↗
17. Carbon nanomaterials and their application to electrochemical sensors: A review10.1515/ntrev-2017-0160 ↗
18. Electrochemical Characterization of Nanogap Interdigitated Electrode Arrays for Lab-on-a-Chip Applications10.1149/2.0701803jes ↗
19. Gold interdigitated nanoelectrodes as a sensitive analytical tool for selective detection of electroactive species via redox cycling10.1007/s00604-016-1792-9 ↗
20. Formaldehyde assay by capacitance versus voltage and impedance measurements using bi-layer bio-recognition membrane10.1016/j.bios.2006.01.019 ↗
21. Afsarimanesh, N., Nag, A., Alahi, M.E.E., Han, T., and Mukhopadhyay, S. (2020). Interdigital sensors: Biomedical, environmental and industrial applications. Sens. Actuators A Phys., 305.10.1016/j.sna.2020.111923 ↗
22. A review of screen-printed silver/silver chloride (Ag/AgCl) reference electrodes potentially suitable for environmental potentiometric sensors10.1016/j.sna.2017.10.013 ↗
23. Michalska, A., Kisiel, A., and Maksymiuk, K. (2013). Screen-Printed Disposable Reference Electrodes. Handbook of Reference Electrodes, Springer.10.1007/978-3-642-36188-3_13 ↗
24. Khan, M., Rahaman, R., Khalilian, A., and Kang, S.-W. (2016). Fast, highly-sensitive, and wide-dynamic-range interdigitated capacitor glucose biosensor using solvatochromic dye-containing sensing membrane. Sensors, 16.10.3390/s16020265 ↗
25. Electrical impedance characterization of cell growth on interdigitated microelectrode array10.1166/jnn.2014.9929 ↗
26. Tech-electrochemical handheld breathalyzer COVID sensing technology10.1038/s41598-022-08321-x ↗
27. Electrical conductivity measurements using microfabricated interdigitated electrodes10.1021/ac00057a016 ↗
28. Electrochemical measurements with interdigitated array microelectrodes
29. Dizon, A., and Orazem, M.E. (2019). On the impedance response of interdigitated electrodes. Electrochim. Acta, 327.10.1016/j.electacta.2019.135000 ↗
30. Generator-collector double electrode systems: A review10.1039/c2an16174e ↗
31. Voltammetric determination of iodide by use of an interdigitated microelectrode array10.1007/s002160101010 ↗
32. Titrations with electrogenerated halogens in the diffusion layer of an interdigitated microelectrode array10.1039/AN9962101795 ↗
33. The linear and non-linear electrical properties of the electrode-electrolyte interface10.1016/0956-5663(95)96795-Z ↗
34. Exploring the interfaces between metal electrodes and aqueous electrolytes with electrochemical impedance spectroscopy10.1039/c3an00791j ↗
35. Electrochemical impedance spectroscopy with interdigitated electrodes at the end of hypodermic needle for depth profiling of biotissues10.1016/j.snb.2016.07.064 ↗
36. Improving sensitivity of a miniaturized label-free electrochemical biosensor using zigzag electrodes10.1016/j.bios.2017.11.065 ↗
37. Interdigitated microelectrode geometry for simple electrical Escherichia coli O157:H7 DNA detection10.1108/MI-08-2016-0054 ↗
38. Cheng, Y.H., Moura, P.A.R., Zhenglong, L., Feng, L., Arokiam, S., Yang, J., Hariharan, M., and Basuray, S. (2019). Effect of electrode configuration on the sensitivity of nucleic acid detection in a non-planar, flow-through, porous interdigitated electrode. Biomicrofluidics, 13.10.1063/1.5126452 ↗
39. Muaz, A., Hashim, U., Liu, W.-W., Ibrahim, F., Thong, K., and Mohktar, M.S. (2014, January 8–10). Fabrication of interdigitated electrodes (IDE’s) by conventional photolithography technique for pH measurement using micro-gap structure. Proceedings of the 2014 IEEE Conference on Biomedical Engineering and Sciences (IECBES), Kuala Lumpur, Malaysia.10.1109/IECBES.2014.7047474 ↗
40. Redox Recycling Amplification Using an Interdigitated Microelectrode Array for Ionic Liquid-Based Oxygen Sensors10.1021/acs.analchem.7b04945 ↗
41. Three-dimensional interdigitated electrode array as a transducer for label-free biosensors10.1016/j.bios.2008.06.057 ↗
42. Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA)10.1373/clinchem.2005.051532 ↗
43. Fabrication and characteristics of vertically separated interdigitated array electrodes10.1016/0022-0728(89)80257-8 ↗
44. Quantitative analysis of the steady-state currents of reversible redox species at a microdisk array electrode embedded in a surface electrode10.1016/0022-0728(90)85003-N ↗
45. Interdigitated array microelectrodes as electrochemical sensors10.1016/S0013-4686(97)00171-0 ↗
46. Electrochemical redox cycling in a new nanogap sensor: Design and simulation10.1016/j.jelechem.2015.11.031 ↗
47. Quantitative analysis of reversible diffusion-controlled currents of redox soluble species at interdigitated array electrodes under steady-state conditions10.1016/0022-0728(88)87003-7 ↗
48. Digital simulation of the measured electrochemical response of reversible redox couples at microelectrode arrays: Consequences arising from closely spaced ultramicroelectrodes10.1021/ac00124a045 ↗
49. The effect of channel height and electrode aspect ratio on redox cycling at carbon interdigitated array nanoelectrodes confined in a microchannel10.1039/c3an00905j ↗
50. Carbon Interdigitated Array Nanoelectrodes for Electrochemical Applications10.1149/1.3531952 ↗
51. An interdigitated electrode with dense carbon nanotube forests on conductive supports for electrochemical biosensors10.1039/C8AN00528A ↗
52. Fast Electron-Transfer Kinetics Probed in Nanofluidic Channels10.1021/ja902331u ↗
53. A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157: H7 in food samples10.1016/j.snb.2007.03.045 ↗
54. Three-Dimensional Carbon Interdigitated Electrode Arrays for Redox-Amplification10.1021/ac4033356 ↗
55. Madou, M. (2002). Fundamentals of Microfabrication: The Science of Miniaturization, CRC.
56. Madou, M., Schmidt, G., Song, X., Kinoshita, K., Fendorf, M., Zettly, A., and White, R. (1997, January 1). Carbon micromachining (c-mems). Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods, Paris, France.
57. Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers10.1021/nn3023969 ↗
58. Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., and Fiore, V. (2016). Analytical problems in exposing amperometric enzyme biosensors to biological fluids. Sensors, 16.10.3390/s16060780 ↗
59. Impedimetric Sensors: Principles, Applications and Recent Trends
60. A review on impedimetric biosensors
61. Conductometric Microbiosensors for Environmental Monitoring10.3390/s8042569 ↗
62. Electrochemical sensors: A powerful tool in analytical chemistry10.1590/S0103-50532003000200003 ↗
63. Willander, M., Tahira, A., and Ibupoto, Z. (2018). Potentiometric Biosensors Based on Metal Oxide Nanostructures. Encyclopedia of Interfacial Chemistry, Elsevier.10.1016/B978-0-12-409547-2.13482-1 ↗
64. The Electrical Double Layer and the Theory of Electrocapillarity10.1021/cr60130a002 ↗
65. Theory of the voltammetric response of electrodes of submicron dimensions. Violation of electroneutrality in the presence of excess supporting electrolyte10.1021/ac00071a002 ↗
66. Dynamic Diffuse Double-Layer Model for the Electrochemistry of Nanometer-Sized Electrodes10.1021/jp060084j ↗
67. How valid is the electroneutrality approximation in the theory of steady-state voltammetry?10.1016/S0022-0728(01)00508-3 ↗
68. Simulating the structure and effect of the electrical double layer at nanometre electrodes10.1088/0957-4484/18/33/335201 ↗
69. The effect of an electrical double layer on the voltammetric performance of nanoscale interdigitated electrodes: A simulation study10.1088/0957-4484/19/46/465504 ↗
70. Bearden, S.L. (2015). Manipulation of the Electrical Double Layer for Control and Sensing in a Solid State Nanopore, Clemson University.
71. A method to determine the parameters of the double layer of a planar interdigital sensor
72. Fleischmann, M., Pons, S., and Rolison, D.R. (1987). Ultramicroelectrodes, Datatech Systems.
73. Microvoltammetric electrodes10.1021/ac00232a004 ↗
74. Linear sweep voltammetry at very small stationary disk electrodes10.1016/0022-0728(84)80115-1 ↗
75. Accurate Simulations of Electric Double Layer Capacitance of Ultramicroelectrodes10.1021/jp204498e ↗
76. Yasuga, H., Shoji, K., Koiwai, K., and Kawano, R. (2021). New Sensing Technologies: Microtas/NEMS/MEMS. Encyclopedia of Sensors and Biosensors, Elsevier.
77. Band Electrodes in Sensing Applications: Response Characteristics and Band Fabrication Methods10.1021/acssensors.9b01172 ↗
78. Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: Consideration of redox cycling and collection efficiency10.1021/ac00204a006 ↗
79. Electrochemical Detection of the Neurotransmitter Dopamine by Nanoimprinted Interdigitated Electrodes and a CMOS Circuit With Enhanced Collection Efficiency10.1109/JSEN.2011.2105260 ↗
80. Integrated Biodetection in a Nanofluidic Device10.1021/nn502678t ↗
81. Biosensor Devices: A review on their biological applications10.21786/bbrc/19.1/20 ↗
82. Direct current-induced breakdown to enhance reproducibility and performance of carbon-based interdigitated electrode arrays for AC electroosmotic micropumps10.1016/j.sna.2017.05.023 ↗
83. Effect of pyrolysis process parameters on electrical, physical, chemical and electro-chemical properties of SU-8-derived carbon structures fabricated using the C-MEMS process10.1016/j.matpr.2017.10.153 ↗
84. SU-8 Photolithography as a Toolbox for Carbon MEMS10.3390/mi5030766 ↗
85. Wang, S., Peng, T., Meng, Q., Zhu, X., Guo, L., Yao, K., Wang, Z., Zheng, P., Ren, Z., and He, Z. (2020). Rapid and ultrasensitive detection of Salmonella typhimurium using a novel impedance biosensor based on SiO2@MnO2 nanocomposites and interdigitated array microelectrodes. Sens. Actuators B Chem., 324.10.1016/j.snb.2020.128654 ↗
86. Aliabadi, E.S. (2021). Carbon Interdigitated Electrode Arrays for Biosensing. [Ph.D. Thesis, UC Irvine].
87. Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement10.1016/j.sna.2006.12.006 ↗
88. Bhura, D.K. (2011). 3D Interdigitated Electrode Array (IDEA) Biosensor For Detection of Serum Biomarker. [Master’s Thesis, Portland State University].
89. Computer aided modelling of an interdigitated microelectrode array impedance biosensor for the detection of bacteria10.1109/TDEI.2009.5293949 ↗
90. Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect10.1007/s10404-013-1231-8 ↗
91. O’Sullivan, B., Patella, B., Daly, R., Seymour, I., Robinson, C., Lovera, P., Rohan, J., Inguanta, R., and O’Riordan, A. (2021). A simulation and experimental study of electrochemical pH control at gold interdigitated electrode arrays. Electrochim. Acta, 395.10.1016/j.electacta.2021.139113 ↗
92. MacKay, S., Hermansen, P., Wishart, D., Hiebert, W., and Chen, J. (2015, January 3–6). Simulating electrical properties of interdigitated electrode designs for impedance-based biosensing applications. Proceedings of the 2015 IEEE 28th Canadian Conference on Electrical and Computer Engineering (CCECE), Halifax, NS, Canada.10.1109/CCECE.2015.7129305 ↗
93. Cyclic voltammetry simulation at microelectrode arrays with COMSOL Multiphysics®10.1007/s10800-009-9797-2 ↗
94. Jun, L.Q., bin Djaswadi, G.W., bin Hawari, H.F., and Zakariya, M.A.B. (2018, January 13–14). Simulation of interdigitated electrodes (IDEs) geometry using COMSOL Multiphysics. Proceedings of the 2018 International Conference on Intelligent and Advanced System (ICIAS), Kuala Lumpur, Malaysia.10.1109/ICIAS.2018.8540599 ↗
95. Investigation of the effect of metallization ratio and side shift on the interdigitated electrodes performance for biochemical sensing10.1007/s10800-021-01549-x ↗
96. Optimization and fabrication of planar interdigitated impedance sensors for highly resistive non-aqueous industrial fluids10.1016/j.snb.2006.01.003 ↗
97. Madou, M.J., Perez-Gonzalez, V.H., and Pramanick, B. (2016). Carbon: The Next Silicon?: Book 2—Applications, Momentum Press.
98. Gold nanoparticles in delivery applications10.1016/j.addr.2008.03.016 ↗
99. Functionalized gold nanoparticle supported sensory mechanisms applied in detection of chemical and biological threat agents: A review10.1016/j.aca.2011.12.008 ↗
100. Gold Nanoparticles: Assembly, Supramolecular Chemistry, Quantum-Size-Related Properties, and Applications toward Biology, Catalysis, and Nanotechnology10.1021/cr030698+ ↗