Human Body–Electrode Interfaces for Wide-Frequency Sensing and Communication: A Review
Source abstract
Abstract
Several on-body sensing and communication applications use electrodes in contact with the human body. Body–electrode interfaces in these cases act as a transducer, converting ionic current in the body to electronic current in the sensing and communication circuits and vice versa. An ideal body–electrode interface should have the characteristics of an electrical short, i.e., the transfer of ionic currents and electronic currents across the interface should happen without any hindrance. However, practical body–electrode interfaces often have definite impedances and potentials that hinder the free flow of currents, affecting the application’s performance. Minimizing the impact of body–electrode interfaces on the application’s performance requires one to understand the physics of such interfaces, how it distorts the signals passing through it, and how the interface-induced signal degradations affect the applications. Our work deals with reviewing these elements in the context of biopotential sensing and human body communication.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wireless Body Area Networks · Neuroscience and Neural Engineering · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906, USA
Eli Lilly and Company, Indianapolis, IN 46285, USA
Funding
Eli Lilly and Company
References (100+)
Show source-provided references
1. Button, V.L.D.S.N. (2015). Principles of Measurement and Transduction of Biomedical Variables, Academic Press.10.1016/B978-0-12-800774-7.00001-5 ↗
2. Biopotential electrodes
3. Zhao, J.F., Chen, X.M., Liang, B.D., and Chen, Q.X. (2017). A review on human body communication: Signal propagation model, communication performance, and experimental Issues. Wirel. Commun. Mob. Comput., 2017.10.1155/2017/5842310 ↗
4. Naranjo-Hernández, D., Callejón-Leblic, A., Lučev Vasić, Ž., Seyedi, M., and Gao, Y.M. (2018). Past results, present trends, and future challenges in intrabody communication. Wirel. Commun. Mob. Comput., 2018.10.1155/2018/9026847 ↗
5. Maity, S., Das, D., Chatterjee, B., and Sen, S. (2018, January 18–21). Characterization and classification of human body channel as a function of excitation and termination modalities. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.10.1109/EMBC.2018.8513332 ↗
6. Bio-physical modeling, characterization, and optimization of electro-quasistatic human body communication10.1109/TBME.2018.2879462 ↗
7. BodyWire: A 6.3-pJ/b 30-Mb/s- 30-dB SIR-tolerant broadband interference-robust human body communication transceiver using time domain interference rejection10.1109/JSSC.2019.2932852 ↗
8. Maity, S., Das, D., and Sen, S. (2017, January 11–15). Wearable health monitoring using capacitive voltage-mode human body communication. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju, Korea.10.1109/EMBC.2017.8036748 ↗
9. A capacitive intrabody communication channel from 100 kHz to 100 MHz10.1109/TIM.2012.2205491 ↗
10. Channel modeling of miniaturized battery-powered capacitive human body communication systems
11. The human body characteristics as a signal transmission medium for intrabody communication10.1109/TMTT.2007.895640 ↗
12. Review of the modeling, simulation and implement of intra-body communication10.1016/j.dt.2013.10.001 ↗
13. A comprehensive study into intrabody communication measurements10.1109/TIM.2013.2258766 ↗
14. Enabling covert body area network using electro-quasistatic human body communication10.1038/s41598-018-38303-x ↗
15. Fahier, N., and Fang, W.C. (2017, January 19–21). An HBC-based continuous bio-potential system monitoring using 30MHz OOK modulation. Proceedings of the 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), Turin, Italy.10.1109/BIOCAS.2017.8325051 ↗
16. (2021, July 14). Zio Monitoring. Available online: https://www.irhythmtech.com/providers/zio-service/zio-monitors.
17. (2021, July 14). Home—VitalConnect. Available online: https://vitalconnect.com/.
18. (2021, July 14). Kardia Mobile EKG|Omron Healthcare. Available online: https://omronhealthcare.com/products/kardia-mobile-ekg-ac009uac/.
19. (2021, July 14). Portable EKG Monitor—Instant EKG Analysis with APP—Wellue Health. Available online: https://getwellue.com/products/duoek-hand-held-wearable-ekg-tracker.
20. (2021, July 14). BardyDx. Available online: https://www.bardydx.com/.
21. (2021, July 14). MAX-ECGMONITOR Wearable ECG and Heart Monitor Evaluation and Development Platform—Maxim Integrated. Available online: https://www.maximintegrated.com/en/products/interface/sensor-interface/MAX-ECGMONITOR.html.
22. Maity, S., Modak, N., Yang, D., Avlani, S., Nath, M., Danial, J., Das, D., Mehrotra, P., and Sen, S. (2020, January 22–25). A 415 nw physically and mathematically secure electro-quasistatic hbc node in 65nm cmos for authentication and medical applications. Proceedings of the 2020 IEEE Custom Integrated Circuits Conference (CICC), Boston, MA, USA.10.1109/CICC48029.2020.9075930 ↗
23. Chen, C.H., Mak, P.I., Zhang, T.T., Vai, M.I., Mak, P.U., Pun, S.H., Wan, F., and Martins, R. (2009, January 19–21). A 2.4 Hz-to-10 kHz-tunable biopotential filter using a novel capacitor multiplier. Proceedings of the 2009 Asia Pacific Conference on Postgraduate Research in Microelectronics & Electronics (PrimeAsia), Shanghai, China.10.1109/PRIMEASIA.2009.5397367 ↗
24. Harrison, R.R. (2007, January 16–19). A versatile integrated circuit for the acquisition of biopotentials. Proceedings of the 2007 IEEE Custom Integrated Circuits Conference, San Jose, CA, USA.10.1109/CICC.2007.4405694 ↗
25. “Virtual” experiment for understanding the electrocardiogram and the mean electrical axis10.1152/advances.2000.23.1.S1 ↗
26. The relation between the surface electromyogram and muscular force10.1113/jphysiol.1975.sp010904 ↗
27. EEG signal analysis: A survey10.1007/s10916-008-9231-z ↗
28. Maling, N., and McIntyre, C. (2016). Closed Loop Neuroscience, Academic Press.
29. Biesheuvel, P., Porada, S., and Dykstra, J. (2018). The difference between Faradaic and non-Faradaic electrode processes. arXiv.
30. Ratner, B.D., Hoffman, A.S., Schoen, F.J., and Lemons, J.E. (2004). Biomaterials Science: An Introduction to Materials in Medicine, Elsevier.
31. Characterization of textile electrodes and conductors using standardized measurement setups10.1088/0967-3334/31/2/009 ↗
32. Xiong, F., Chen, D., Chen, Z., Jin, C., and Dai, S. (2019). Advances in Body Area Networks I, Springer.
33. Electrical stimulation of excitable tissue: Design of efficacious and safe protocols10.1016/j.jneumeth.2004.10.020 ↗
34. Wearable sensors: Modalities, challenges, and prospects10.1039/C7LC00914C ↗
35. Lu, F., Wang, C., Zhao, R., Du, L., Fang, Z., Guo, X., and Zhao, Z. (2018). Review of stratum corneum impedance measurement in non-invasive penetration application. Biosensors, 8.10.3390/bios8020031 ↗
36. Human skin battery potentials and their possible role in wound healing10.1111/j.1365-2133.1983.tb07673.x ↗
37. Epidermal impedance sensing sheets for precision hydration assessment and spatial mapping10.1109/TBME.2013.2264879 ↗
38. Skin impedance and moisturization
39. Fabric-based wearable dry electrodes for body surface biopotential recording10.1109/TBME.2015.2462312 ↗
40. Wearable silver nanowire dry electrodes for electrophysiological sensing10.1039/C4RA15101A ↗
41. Effect of pressure and padding on motion artifact of textile electrodes
42. A flexible dry electrode based on APTES-anchored PDMS substrate for portable ECG acquisition system10.1007/s00542-015-2490-y ↗
43. Flexible polymeric dry electrodes for the long-term monitoring of ECG10.1016/j.sna.2007.11.019 ↗
44. Nanomaterial-enabled dry electrodes for electrophysiological sensing: A review10.1007/s11837-016-1818-0 ↗
45. Capacitive epidermal electronics for electrically safe, long-term electrophysiological measurements10.1002/adhm.201300334 ↗
46. Novel semi-dry electrodes for brain–computer interface applications10.1088/1741-2560/13/4/046021 ↗
47. Review of semi-dry electrodes for EEG recording10.1088/1741-2552/abbd50 ↗
48. Towards real-life EEG applications: Novel superporous hydrogel-based semi-dry EEG electrodes enabling automatically ‘charge–discharge’ electrolyte10.1088/1741-2552/abeeab ↗
49. Novel passive ceramic based semi-dry electrodes for recording electroencephalography signals from the hairy scalp10.1016/j.snb.2016.06.045 ↗
50. Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting10.1016/j.snb.2018.08.155 ↗
51. (2021, May 08). The Wet-EEG Cap: Semi-Dry, Saline & Gel EEG Caps|Bitbrain. Available online: https://www.bitbrain.com/blog/wet-eeg-cap.
52. Integrated circuits and electrode interfaces for noninvasive physiological monitoring10.1109/TBME.2014.2308552 ↗
53. Nano-bio-textile sensors with mobile wireless platform for wearable health monitoring of neurological and cardiovascular disorders10.1149/2.012402jes ↗
54. Assambo, C., Baba, A., Dozio, R., and Burke, M. (2007, January 16–19). Determination of the parameters of the skin-electrode impedance model for ECG measurement. Proceedings of the 6th WSEAS International Conference on Electronics, Hardware, Wireless and Optical Communications, Corfu Island, Greece.
55. Kusche, R., Kaufmann, S., and Ryschka, M. (2018). Dry electrodes for bioimpedance measurements—Design, characterization and comparison. Biomed. Phys. Eng. Express, 5.10.1088/2057-1976/aaea59 ↗
56. Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation10.3390/s110605819 ↗
57. Dry-contact and noncontact biopotential electrodes: Methodological review10.1109/RBME.2010.2084078 ↗
58. Xu, J., Mohan, R., Van Helleputte, N., and Mitra, S. (2018). CMOS Circuits for Biological Sensing and Processing, Springer.
59. Towards gel-free electrodes: A systematic study of electrode-skin impedance10.1016/j.snb.2016.10.005 ↗
60. Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography10.1007/BF02523842 ↗
61. Oster, C.D. (2021, August 06). Proper Skin Prep Helps Ensure ECG Trace Quality. Available online: https://multimedia.3m.com/mws/media/358372O/proper-skin-prep-ecg-trace-quality-white-paper.pdf.
62. Passive Impedance Matching for Implanted Brain–Electrode Interfaces10.1109/JERM.2019.2904024 ↗
63. Reducing motion artifacts and interference in biopotential recording10.1109/TBME.1984.325244 ↗
64. Standards of instrumentation of EMG10.1016/j.clinph.2019.07.025 ↗
65. Motion artifact removal techniques for wearable EEG and PPG sensor systems10.3389/felec.2021.685513 ↗
66. Correlation between electrode-tissue impedance and motion artifact in biopotential recordings10.1109/JSEN.2012.2221163 ↗
67. The origin of skin-stretch-caused motion artifacts under electrodes10.1088/0967-3334/17/2/003 ↗
68. Reducing skin potential motion artefact by skin abrasion10.1007/BF02442929 ↗
69. Motion artifact from electrodes and cables
70. (2021, July 18). Triboelectric Noise in Medical Cables and Wires|Experience Molex. Available online: https://experience.molex.com/triboelectric-noise-in-medical-cables-and-wires/.
71. Yang, D., Mehrotra, P., Weigand, S., and Sen, S. (2021). In-The-Wild Interference Characterization and Modelling for Electro-Quasistatic-HBC with Miniaturized Wearables. IEEE Trans. Biomed. Eng.10.1101/2020.11.06.372060 ↗
72. Towards emerging EEG applications: A novel printable flexible Ag/AgCl dry electrode array for robust recording of EEG signals at forehead sites10.1088/1741-2552/ab71ea ↗
73. Dillingham, T., Andary, M., and Dumitru, D. (2021). Braddom’s Physical Medicine and Rehabilitation, Elsevier.
74. Worsfold, P., Townshend, A., and Poole, C. (2005). Encyclopedia of Analytical Science, Elsevier. [2nd ed.].
75. Enderle, J.D., and Bronzino, J.D. (2012). Introduction to Biomedical Engineering, Academic Press. [3rd ed.]. Biomedical Engineering.
76. Materials for Implantable Electrodes10.1557/S088376940006913X ↗
77. Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes10.1007/BF02368010 ↗
78. Generation of resting membrane potential10.1152/advan.00029.2004 ↗
79. Skeletal muscle physiology10.1093/bjaceaccp/mki062 ↗
80. (2021, August 16). PASCO CI-6539A EKG SENSOR User Manual. Available online: https://manualmachine.com/pasco/ci6539aekgsensor/1700487-user-manual/.
81. Dry EEG electrodes10.3390/s140712847 ↗
82. Portable out-of-hospital electrocardiography: A review of current technologies10.1002/joa3.12035 ↗
83. Occult atrial fibrillation in cryptogenic stroke: Detection by 7-day electrocardiogram versus implantable cardiac monitors10.1161/STROKEAHA.111.676189 ↗
84. Wyngaarden, J.B., and Smith, L.H. (1982). Cecil Textbook of Medicine, W B Saunders.
85. Clinical significance of ST segment depression in lead aVR to predict culprit artery in an acute inferior wall myocardial infarction10.3126/njh.v12i1.12324 ↗
86. ST segment elevations: Always a marker of acute myocardial infarction?10.1016/j.ihj.2013.06.013 ↗
87. Jiang, Y., Samuel, O.W., Liu, X., Wang, X., Idowu, P.O., Li, P., Chen, F., Zhu, M., Geng, Y., and Wu, F. (2018). Effective biopotential signal acquisition: Comparison of different shielded drive technologies. Appl. Sci., 8.10.3390/app8020276 ↗
88. Physio Control Inc. (2015). Physio-Control, Physio Control Inc.
89. An, X., and Stylios, G.K. (2020). Comparison of motion artefact reduction methods and the implementation of adaptive motion artefact reduction in wearable electrocardiogram monitoring. Sensors, 20.10.3390/s20051468 ↗
90. Babusiak, B., Borik, S., and Smondrk, M. (2020). Two-Electrode ECG for Ambulatory Monitoring with Minimal Hardware Complexity. Sensors, 20.10.3390/s20082386 ↗
91. Acharya, V. (2011). Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier, Texas Instruments.
92. Yamamoto, Y. (1998, January 18–21). Impedance balancing analysis for power-line interference elimination in ECG signal. Proceedings of the IMTC/98 Conference Proceedings, IEEE Instrumentation and Measurement Technology Conference, Where Instrumentation is Going (Cat. No. 98CH36222), St. Paul, MN, USA.
93. Becchetti, C., and Neri, A. (2013). Medical Instrument Design and Development: From Requirements to Market Placements, John Wiley & Sons.
94. Nash, E., and Devices, A. (1998). Common Mode and Instrumentation Amplifiers, Analog Devices.
95. Two-electrode biopotential amplifier with current-driven inputs10.1007/BF02347705 ↗
96. A 24.8-μW Biopotential Amplifier Tolerant to 15-VPP Common-Mode Interference for Two-Electrode ECG Recording in 180-nm CMOS10.1109/JSSC.2020.3005768 ↗
97. Characterization and modeling of the capacitive HBC channel10.1109/TIM.2015.2420391 ↗
98. Toward understanding the return path capacitance in capacitive human body communication
99. Inter-body coupling in electro-quasistatic human body communication: Theory and analysis of security and interference properties10.1038/s41598-020-79788-9 ↗
100. Wegmüller, M.S. (2007). Intra-Body Communication for Biomedical Sensor Networks. [Ph.D. Thesis, ETH Zurich].