journal article·2019-07-11Open access

Fabrication of Troponin I Biosensor Composed of Multi-Functional DNA Structure/Au Nanocrystal Using Electrochemical and Localized Surface Plasmon Resonance Dual-Detection Method

Taek Lee, Jinmyeong Kim, Inho Nam, Yeonju Lee, Ha Eun Kim, Hiesang Sohn, Seong-Eun Kim, Jinho Yoon, Sang Woo Seo, Min-Ho Lee, Chulhwan Park

Nanomaterials· Volume 9· Issue 7

Abstract

In the present study, we fabricated a dual-mode cardiac troponin I (cTnI) biosensor comprised of multi-functional DNA (MF-DNA) on Au nanocrystal (AuNC) using an electrochemical method (EC) and a localized surface plasmon resonance (LSPR) method. To construct a cTnI bioprobe, a DNA 3 way-junction (3WJ) was prepared to introduce multi-functionality. Each DNA 3WJ arm was modified to possess a recognition region (Troponin I detection aptamer), an EC-LSPR signal generation region (methylene blue: MB), and an anchoring region (Thiol group), respectively. After an annealing step, the multi-functional DNA 3WJ was assembled, and its configuration was confirmed by Native-TBM PAGE for subsequent use in biosensor construction. cTnI was also expressed and purified for use in biosensor experiments. To construct an EC-LSPR dual-mode biosensor, AuNCs were prepared on an indium-tin-oxide (ITO) substrate using an electrodeposition method. The prepared multi-functional (MF)-DNA was then immobilized onto AuNCs by covalent bonding. Field emission scanning electron microscope (FE-SEM) and atomic force microscopy (AFM) were used to analyze the surface morphology. LSPR and electrochemical impedance spectroscopy (EIS) experiments were performed to confirm the binding between the target and the bioprobe. The results indicated that cTnI could be effectively detected in the buffer solution and in diluted-human serum. Based on the results of these experiments, the loss on drying (LOD) was determined to be 1.0 pM in HEPES solution and 1.0 pM in 10% diluted human serum. Additionally, the selectivity assay was successfully tested using a number of different proteins. Taken together, the results of our study indicate that the proposed dual-mode biosensor is applicable for use in field-ready cTnI diagnosis systems for emergency situations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Integrated Circuits and Semiconductor Failure Analysis · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering, Kwangwoon University, Wolgye-dong, Nowon-gu, Seoul 01899, Korea

Department of Chemical Engineering and Materials Science, Chung-Ang University, Heukseok-dong, Dongjak-gu, Seoul 06974, Korea

Human IT Convergence Research Center, Korea Electronics Technology Institute, Seongnam-si, Gyeonggi-do 13509, Korea

Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea

School of Chemical and Biological Engineering, Institute of Chemical Process, Seoul National University, Seoul 08826, Korea

School of Integrative Engineering Chung-Ang University, Heukseok-dong, Dongjak-gu, Seoul 06974, Korea

Funding

Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education · National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) · Bio & Medical Technology Development Program of the NRF funded by the Korean government, MSIT

References (34)

Show source-provided references
1. Sutcliffe, P., Connock, M., Gurung, T., Freeman, K., Johnson, S., Ngianga-Bakwin, K., Grove, A., Gurung, B., Stranges, S., and Clarke, A. (2013). Aspirin in primary prevention of cardiovascular disease and cancer: A systematic review of the balance of evidence from reviews of randomized trials. PLoS ONE, 8.10.1371/journal.pone.0081970 ↗
2. Cardiovascular disease detection using bio-sensing techniques10.1016/j.talanta.2014.04.060 ↗
3. Ischemic heart disease in women: A focus on risk factors10.1016/j.tcm.2014.10.005 ↗
4. Prevalence, incidence, predictive factors and prognosis of silent myocardial infarction: A review of the literature10.1016/j.acvd.2010.11.013 ↗
5. Mechanical complications of acute myocardial infarction10.1016/j.ccl.2013.07.004 ↗
6. Evolution of myocardial infarction and its biomarkers: A historical perspective10.4103/1995-705X.201786 ↗
7. Biochemical markers of myocardial damage
8. Diagnostic markers of acute myocardial infarction10.3892/br.2015.500 ↗
9. Biosensors for cardiac biomarkers detection: A review10.1016/j.snb.2012.05.077 ↗
10. Electrochemical aptasensor of cardiac troponin I for the early diagnosis of acute myocardial infarction10.1021/acs.analchem.5b02312 ↗
11. Recent development of cardiac troponin I detection10.1021/acssensors.5b00318 ↗
12. Silicon nanowire biosensors for detection of cardiac troponin I (cTnI) with high sensitivity10.1016/j.bios.2015.10.008 ↗
13. Functionalized SnO2 nanobelt field-effect transistor sensors for label-free detection of cardiac troponin10.1016/j.bios.2011.05.019 ↗
14. Fabrication of electrochemical biosensor composed of multi-functional DNA structure/Au nanospike on micro-gap/PCB system for detecting troponin I in human serum10.1016/j.colsurfb.2018.11.078 ↗
15. Quenching effect on gold nano-patterned cardiac troponin I chip by total internal reflection fluorescence microscopy10.1016/j.talanta.2012.11.014 ↗
16. Ultrahigh sensitivity assays for human cardiac troponin I using TiO2 nanotube arrays10.1039/c2lc20892j ↗
17. Moore, T.J., Moody, A.S., Payne, T.D., Sarabia, G.M., Daniel, A.R., and Sharma, B. (2018). In vitro and in vivo SERS biosensing for disease diagnosis. Biosensors, 8.10.3390/bios8020046 ↗
18. Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography10.1016/j.aca.2008.11.019 ↗
19. On/off-switchable LSPR nano-immunoassay for troponin-T10.1038/srep44027 ↗
20. Fabrication of anti-human cardiac troponin I immunogold nanorods for sensing acute myocardial damage10.1007/s11671-009-9415-6 ↗
21. Thermodynamically stable RNA three-way junctions for constructing multifuntional nanoparticles for delivery of therapeutics10.1038/nnano.2011.105 ↗
22. Binding-induced formation of DNA three-way junctions and its application to protein detection and DNA strand displacement10.1021/ac402179a ↗
23. Nanoparticles of methylene blue enhance photodynamic therapy10.1016/j.pdpdt.2018.06.011 ↗
24. Plasmon-enhanced fluorescence biosensors: A review10.1007/s11468-013-9660-5 ↗
25. Highly sensitive localized surface plasmon resonance immunosensor for label-free detection of HIV-110.1016/j.nano.2013.03.005 ↗
26. Fabrication of electrochemical biosensor consisted of multi-functional DNA structure/porous Au nanoparticle for avian influenza virus (H5N1) in human serum10.1016/j.msec.2019.02.001 ↗
27. Multilevel biomemory device consisting of recombinant azurin/cytochrome c10.1002/adma.200902288 ↗
28. Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform10.1016/j.snb.2013.12.066 ↗
29. A polyaniline based ultrasensitive potentiometric immunosensor for cardiac troponin complex detection10.1016/j.bios.2015.04.084 ↗
30. Electrochemical immunosensor for simultaneous detection of dual cardiac markers based on a poly (dimethylsiloxane)-gold nanoparticles composite microfluidic chip: A proof of principle10.1373/clinchem.2010.147256 ↗
31. Electrochemical detection of cardiac biomarker troponin I at gold nanoparticle-modified ITO electrode by using open circuit potential10.1016/S1452-3981(23)18155-7 ↗
32. Tunable plasmon Resonances in two-dimensional molybdenum oxide nanoflakes10.1002/adma.201306097 ↗
33. Plasmon resonances of highly doped two-dimensional MoS210.1021/nl503563g ↗
34. Bifunctional Au@Bi2Se3 core–shell nanoparticle for synergetic therapy by SERS-traceable antagomiR delivery and photothermal treatment10.1002/smll.201802934 ↗