journal article·2019-12-27Open access

Peroxide Electrochemical Sensor and Biosensor Based on Nanocomposite of TiO2 Nanoparticle/Multi-Walled Carbon Nanotube Modified Glassy Carbon Electrode

L. Andrés Guerrero, Lenys Fernández, Gema González, Marjorie Montero-Jiménez, Rafael Uribe, Antonio Díaz Barrios, Patricio J. Espinoza-Montero

Nanomaterials· Volume 10· Issue 1

Abstract

A hydrogen peroxide (H2O2) sensor and biosensor based on modified multi-walled carbon nanotubes (CNTs) with titanium dioxide (TiO2) nanostructures was designed and evaluated. The construction of the sensor was performed using a glassy carbon (GC) modified electrode with a TiO2–CNT film and Prussian blue (PB) as an electrocalatyzer. The same sensor was also employed as the basis for H2O2 biosensor construction through further modification with horseradish peroxidase (HRP) immobilized at the TiO2–fCNT film. Functionalized CNTs (fCNTs) and modified TiO2–fCNTs were characterized by Transmission Electron Microscopy (TEM), Fourier Transform Infrared Spectroscopy (FTIR), and X-Ray DifFraction (XRD), confirming the presence of anatase over the fCNTs. Depending on the surface charge, a solvent which optimizes the CNT dispersion was selected: dimethyl formamide (DMF) for fCNTs and sodium dodecylsulfate (SDS) for TiO2–fCNTs. Calculated values for the electron transfer rate constant (ks) were 0.027 s−1 at the PB–fCNT/GC modified electrode and 4.7 × 10−4 s−1 at the PB–TiO2/fCNT/GC electrode, suggesting that, at the PB–TiO2/fCNT/GC modified electrode, the electronic transfer was improved. According to these results, the PB–fCNT/GC electrode exhibited better Detection Limit (LD) and Quantification Limit (LQ) than the PB–TiO2/fCNT/GC electrode for H2O2. However, the PB film was very unstable at the potentials used. Therefore, the PB–TiO2/fCNT/GC modified electrode was considered the best for H2O2 detection in terms of operability. Cyclic Voltammetry (CV) behaviors of the HRP–TiO2/fCNT/GC modified electrodes before and after the chronoamperometric test for H2O2, suggest the high stability of the enzymatic electrode. In comparison with other HRP/fCNT-based electrochemical biosensors previously described in the literature, the HRP–fCNTs/GC modified electrode did not show an electroanalytical response toward H2O2.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Electrochemical Analysis and Applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Escuela de Ciencias Químicas, Pontificia Universidad Católica del Ecuador, Av. 12 de Octubre 1076, Apartado, Quito 17-01-2184, Ecuador

School of Physics and Nanotechnology, Yachay Tech University, Urcuqui 100650, Ecuador

Departamento de Química, Universidad Simón Bolívar, Caracas 89000, Venezuela

Instituto Venezolano de Investigaciones Científicas, Centro de Ingeniería Materiales y Nanotecnología, Caracas 1020-A, Venezuela

Departamento de Ingeniería Química, Escuela Politécnica Nacional, Quito 17-01-2759, Ecuador

Funding

Corporación Ecuatoriana para el Desarrollo de la Investigación y la Academia

References (54)

Show source-provided references
1. Biomaterials and Bioengineering Tomorrow’s Healthcare10.4161/biom.24717 ↗
2. Carbon-Nanotube Based Electrochemical Biosensors: A Review10.1002/elan.200403113 ↗
3. Carbon Nanotubes: Properties, Synthesis, Purification, and Medical Applications10.1186/1556-276X-9-393 ↗
4. Integration of Carbon Nanotubes with Semiconductor Technology: Fabrication of Hybrid Devices by III-V Molecular Beam Epitaxy10.1088/0268-1242/21/11/S02 ↗
5. Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors10.1021/ac060830g ↗
6. Interactions between Single-Walled Carbon Nanotubes and Tetraphenyl Metalloporphyrins: Correlation between Spectroscopic and FET Measurements10.1021/jp0690289 ↗
7. Full-Length Single-Walled Carbon Nanotubes Decorated with Streptavidin-Conjugated Quantum Dots as Multivalent Intracellular Fluorescent Nanoprobes10.1021/bm0602031 ↗
8. An Amperometric Acetylthiocholine Sensor Based on Immobilization of Acetylcholinesterase on a Multiwall Carbon Nanotube—Cross-Linked Chitosan Composite10.1007/s00216-006-0972-6 ↗
9. Functionalized Carbon Nanotubes and Nanofibers for Biosensing Applications10.1016/j.trac.2008.05.009 ↗
10. Highly Sensitive Electrochemical Immunosensor for IgG Detection Based on Optimized Rigid Biocomposites10.1016/j.bios.2015.11.081 ↗
11. Improvement of the Detection Limit for Biosensors: Advances on the Optimization of Biocomposite Composition10.1016/j.microc.2014.11.004 ↗
12. Electrochemistry and Electroanalytical Applications of Carbon Nanotubes: A Review10.2116/analsci.21.1383 ↗
13. Carbon Nanotube-Modified Electrodes for the Simultaneous Determination of Dopamine and Ascorbic Acid10.1039/b201060g ↗
14. A Simple Route to Incorporate Redox Mediator into Carbon nanotubes/Nafion Composite Film and Its Application to Determine NADH at Low Potential10.1016/j.talanta.2007.05.042 ↗
15. Fabrication of polythionine/NPAu/MWNTs Modified Electrode for Simultaneous Determination of Adenine and Guanine in DNA10.1016/j.snb.2007.06.028 ↗
16. The Synergistic Effect of Prussian-Blue-Grafted Carbon Nanotube/Poly(4-Vinylpyridine) Composites for Amperometric Sensing10.1002/adfm.200600033 ↗
17. Methods for Detection and Measurement of Hydrogen Peroxide Inside and Outside of Cells10.1007/s10059-010-0082-3 ↗
18. Methods to Detect Hydrogen Peroxide in Living Cells: Possibilities and Pitfalls10.1016/j.cbpa.2013.02.003 ↗
19. A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes10.1080/00032719408000297 ↗
20. Fabrication of an Amperometric Glucose Biosensor Based on a Prussian Blue/Carbon Nanotube/Ionic Liquid Modified Glassy Carbon Electrode
21. Detection of Hydrogen Peroxide at Mesoporous Platinum Microelectrodes10.1021/ac011052p ↗
22. Functionalized Carbon Nanotubes: Properties and Applications10.1021/ar010160v ↗
23. Helical Wrapping of Single-Walled Carbon Nanotubes by Water Soluble Poly(p-Phenyleneethynylene)10.1021/nl8032334 ↗
24. Polymer-Encapsulated Carbon Nanotubes Prepared through Ultrasonically Initiated In Situ Emulsion Polymerization10.1021/cm0341890 ↗
25. Nanostructured Metal Oxide-Based Biosensors10.1038/asiamat.2010.137 ↗
26. Tailored Titanium Dioxide Photocatalysts for the Degradation of Organic Dyes in Wastewater Treatment: A Review10.1016/j.apcata.2009.02.043 ↗
27. Titanium Dioxide Nanomaterials for Sensor Applications10.1021/cr400625j ↗
28. Nanocomposite Building Blocks of TiO2-MWCNTf and ZrO2-MWCNTf10.1016/j.matchar.2011.10.002 ↗
29. Preparation of Reproducible Glassy Carbon Electrodes by Removal of Polishing Impurities10.1016/S0022-0728(02)01264-0 ↗
30. On the Mechanism of H2O2 Reduction at Prussian Blue Modified Electrodes10.1016/S1388-2481(99)00010-7 ↗
31. Glucose Biosensor Based on Titanium Dioxide-Multiwall Carbon Nanotubes-Chitosan Composite and Functionalized Gold Nanoparticles10.1007/s00449-011-0565-4 ↗
32. Glucose Determination in Beverages Using Carbon Nanotube Modified Biosensor: An Experiment for the Undergraduate Laboratory10.1021/ed300429a ↗
33. Variations of Interlayer Spacing in Carbon Nanotubes10.1039/C4RA04201H ↗
34. Titania Based Nanocomposites as a Photocatalyst: A Review
35. The Scherrer Formula for X-Ray Particle Size Determination10.1103/PhysRev.56.978 ↗
36. Effect of Carboxylic Group Functionalized on Carbon Nanotubes Surface on the Removal of Lead From Water10.1155/2010/603978 ↗
37. Effect of MWCNT Functionalization on Thermal and Electrical Properties of PHBV/MWCNT Nanocomposites10.1557/jmr.2014.303 ↗
38. Synthesis and Characterization of Nanostructures: MWCNTf/TiO2 and MWCNTf/TiO2/HAp10.1002/masy.201251112 ↗
39. High-Concentration Zeta Potential Measurements Using Light-Scattering Techniques
40. McNeil, S.E. (2011). Zeta Potential Measurement BT—Characterization of Nanoparticles Intended for Drug Delivery, Humana Press.
41. Carbon Nanotube Dispersion in Solvents and Polymer Solutions: Mechanisms, Assembly, and Preferences10.1021/acsnano.7b07684 ↗
42. The Role of Surfactants in Dispersion of Carbon Nanotubes10.1016/j.cis.2006.11.007 ↗
43. Biesheuvel, P.M., and Dykstra, J.E. (2018). The Difference between Faradaic and Nonfaradaic Processes in Electrochemistry. arXiv.
44. Amperometric Biosensors Based on the Immobilization of Oxidases in a Prussian Blue Film by Electrochemical Codeposition10.1016/0003-2670(95)00152-P ↗
45. Amperometric Glucose Biosensor Based on Immobilization of Glucose Oxidase in Electropolymerized O-Aminophenol Film at Prussian Blue-Modified Platinum Electrode10.1016/j.electacta.2003.09.033 ↗
46. Electrochemistry of Prussian Blue. An in Situ Moessbauer Effect Measurement10.1021/j100210a033 ↗
47. Electrical and Optical Properties of TiO2 Anatase Thin Films10.1063/1.356306 ↗
48. Electrochemical Behavior and Application of Prussian Blue Nanoparticle Modified Graphite Electrode10.1016/j.snb.2010.03.020 ↗
49. Wang, J., and Zhang, Z. (1994). Analytical Chemistry, VCH. Trans. Tech. Publ.
50. A New Peroxidase from Leaves of Guinea Grass (Panicum Maximum): A Potential Biocatalyst to Build Amperometric Biosensors10.1016/j.bioelechem.2017.03.005 ↗
51. Photoelectrochemical Detection of H2O2 Based on Flower-Like CuInS2-Graphene Hybrid10.1002/elan.201300515 ↗
52. In Situ Controllable Growth of Prussian Blue Nanocubes on Reduced Graphene Oxide: Facile Synthesis and Their Application as Enhanced Nanoelectrocatalyst for H2O2 Reduction10.1021/am100372m ↗
53. Teepoo, S., Dawan, P., and Barnthip, N. (2017). Electrospun Chitosan-Gelatin Biopolymer Composite Nanofibers for Horseradish Peroxidase Immobilization in a Hydrogen Peroxide Biosensor. Biosensors, 7.10.3390/bios7040047 ↗
54. Nonenzymatic H2O2 Sensor Based on Pt Nanoflower Electrode10.1007/s10876-012-0497-4 ↗