Abstract

Glaucoma, a leading cause of blindness, demands innovative and effective treatments that surpass the limitations of current drug and surgical interventions to lower intraocular pressure. This study describes the generation of cell-repellent hydrogel patches, their deposition on the ocular surface, and a photoinduced chemical binding between the patches and the collagens of the eye. The hydrophilic and protein-repellent hydrogel patch is composed of a copolymer made from dimethylacrylamide and a comonomer unit with anthraquinone moieties. A thin layer of the prepolymer is deposited on a flexible foil. This foil has a hydrophobic side on top and superhydrophilic sides on the bottom. A small amount of added water can penetrate easily through the foil and release the polymer, which is thus transferred from the foil onto the eye at the desired location. Through brief irradiation with UV light with a wavelength of 365 nm, the prepolymer is simultaneously cross-linked and covalently attached to the eye's surface through C-H insertion reactions. We describe the handling, attachment, UV irradiation effects on nearby healthy tissues, biocompatibility, stability, and cellular interaction of the patches during in vitro studies.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Glaucoma and retinal disorders · Ocular Surface and Contact Lens · Retinal and Macular Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Microsystems Engineering (IMTEK), Laboratory for Chemistry & Physics of Interfaces (CPI), Albert Ludwigs Universität Freiburg, Georges Köhler Allee 103, 79110 Freiburg, Germany

Eye Center, Medical Center − University of Freiburg, Faculty of Medicine, University of Freiburg, Killianstraße 5, 79106 Freiburg, Germany

Cluster of Excellence livMatS @ FIT−Freiburg Center of Interactive Materials and Bioinspired Technologies Albert Ludwigs Universität Freiburg, Georges Köhler Allee 105, 79110 Freiburg, Germany

Funding

Deutsche Forschungsgemeinschaft

References (50)

Show source-provided references
1. 10.1136/bjo.80.5.38910.1136/bjo.80.5.389 ↗
2. 10.1007/s00347-003-0810-610.1007/s00347-003-0810-6 ↗
3. 10.1016/j.eswa.2022.11720210.1016/j.eswa.2022.117202 ↗
4. 10.1016/j.ophtha.2020.10.02310.1016/j.ophtha.2020.10.023 ↗
5. 2019
6. 10.1016/j.ophtha.2014.05.01310.1016/j.ophtha.2014.05.013 ↗
7. 10.1001/archopht.122.4.53210.1001/archopht.122.4.532 ↗
8. 10.1001/archophthalmol.2011.26110.1001/archophthalmol.2011.261 ↗
9. 10.1001/archopht.122.4.45110.1001/archopht.122.4.451 ↗
10. 10.1016/j.ajo.2012.02.02410.1016/j.ajo.2012.02.024 ↗
11. 10.1097/IJG.000000000000226110.1097/IJG.0000000000002261 ↗
12. 10.3390/bioengineering1102012210.3390/bioengineering11020122 ↗
13. 10.3389/fphys.2023.118406010.3389/fphys.2023.1184060 ↗
14. 10.18240/ijo.2021.11.1110.18240/ijo.2021.11.11 ↗
15. 10.1056/NEJM19911114325200510.1056/NEJM199111143252005 ↗
16. 10.3390/jcm1205182810.3390/jcm12051828 ↗
17. 10.1007/s00347-002-0763-110.1007/s00347-002-0763-1 ↗
18. 10.1023/A:100623862407210.1023/A:1006238624072 ↗
19. 10.1001/archopht.1983.0104001079502110.1001/archopht.1983.01040010795021 ↗
20. Hitchings R. A. · Trans. Ophthalmol. Soc. U. K. (1962) · 1983 · 103 · 84
21. 10.1007/BF0019071210.1007/BF00190712 ↗
22. 10.1016/0002-9394(80)90118-X10.1016/0002-9394(80)90118-X ↗
23. 10.1055/s-2008-104568610.1055/s-2008-1045686 ↗
24. 10.1089/jop.1990.6.17510.1089/jop.1990.6.175 ↗
25. 10.1001/archopht.1978.0391005054100910.1001/archopht.1978.03910050541009 ↗
26. 10.1111/aos.1280510.1111/aos.12805 ↗
27. 10.1136/bmjopen-2022-06592110.1136/bmjopen-2022-065921 ↗
28. 10.1097/ICU.000000000000054910.1097/ICU.0000000000000549 ↗
29. 10.1016/S0161-6420(97)30193-610.1016/S0161-6420(97)30193-6 ↗
30. 10.1021/acs.biomac.7b0010010.1021/acs.biomac.7b00100 ↗
31. 10.1163/15685620677836605910.1163/156856206778366059 ↗
32. 10.1116/1.499978610.1116/1.4999786 ↗
33. 10.1002/admi.20220158110.1002/admi.202201581 ↗
34. 10.1016/j.triboint.2019.02.04510.1016/j.triboint.2019.02.045 ↗
35. 10.1021/la402323k10.1021/la402323k ↗
36. 10.1002/adfm.20130084610.1002/adfm.201300846 ↗
37. 10.1021/ma034737v10.1021/ma034737v ↗
38. 10.1021/acs.macromol.1c0012110.1021/acs.macromol.1c00121 ↗
39. 10.1002/admi.20230031610.1002/admi.202300316 ↗
40. 10.1021/acs.langmuir.1c0066910.1021/acs.langmuir.1c00669 ↗
41. 10.1021/bm010021110.1021/bm0100211 ↗
42. 10.1021/jacs.1c0213310.1021/jacs.1c02133 ↗
43. 10.1002/marc.20190035210.1002/marc.201900352 ↗
44. 10.1097/MAT.000000000000011810.1097/MAT.0000000000000118 ↗
45. 10.1039/c2jm30820g10.1039/c2jm30820g ↗
46. 10.1002/mabi.20120044510.1002/mabi.201200445 ↗
47. 10.1021/ja00751a00310.1021/ja00751a003 ↗
48. 10.1007/s00348-014-1713-910.1007/s00348-014-1713-9 ↗
49. 10.1021/acs.macromol.5b0273410.1021/acs.macromol.5b02734 ↗
50. 10.1016/0006-2952(75)90016-710.1016/0006-2952(75)90016-7 ↗