Trapping, manipulation, and crystallization of live cells using magnetofluidic tweezers
Source abstract
Abstract
Live mammalian cells are captured and manipulated in magnetofluidic traps created in a suspension of biocompatible, magnetic nanoparticles by a coaxial magnetic/non-magnetic "micropen". Upon activation by an external electromagnet, the pen creates microscale gradients of magnetic field and nanoparticle concentration that translate into directional and confining forces acting on the cells. Both individual cells and cell collections can be trapped by this method, allowing, for instance, for the formation of regularly shaped cell assemblies. The method does not entail any local heating artifacts and does not require magnetic tagging of the cells.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Microfluidic and Bio-sensing Technologies · 3D Printing in Biomedical Research · Electrohydrodynamics and Fluid Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Applied Physics
Aalto University
Espoo
Finland
Department of Chemical and Biological Engineering
Northwestern University
Evanston
USA
Feinberg School of Medicine
Department of Chemistry
Indian Institute of Science Education and Research (IISER)
Pune
India
IBS Center for Soft and Living Matter
UNIST
Ulsan
South Korea
Funding
Basic Energy Sciences
References (19)
Show source-provided references
1. S. Lindström and H.Andersson-Svahn, Single-Cell Analysis: Methods and Protocols, Humana Press, New York, 201210.1007/978-1-61779-567-1 ↗
2. S. D. Fleming and R. S.King, Micromanipulation in Assisted Conception, Cambridge University Press, Cambridge, 2012
3. Ashkin · Nature · 1987 · 330 · 76910.1038/330769a0 ↗
4. Ashkin · Science · 1987 · 235 · 151710.1126/science.3547653 ↗
5. Bonakdar · Biochem. Biophys. Res. Commun. · 2012 · 419 · 70310.1016/j.bbrc.2012.02.083 ↗
6. Timonen · Adv. Mater. · 2016 · 28 · 345310.1002/adma.201506072 ↗
7. Moore · J. Magn. Reson. Imaging · 1997 · 7 · 114010.1002/jmri.1880070629 ↗
8. Shen · Magn. Reson. Med. · 1993 · 29 · 59910.1002/mrm.1910290504 ↗
9. Grover · Proc. Natl. Acad. Sci. U. S. A. · 2011 · 108 · 1099210.1073/pnas.1104651108 ↗
10. Ladoux · Rep. Prog. Phys. · 2012 · 75 · 11660110.1088/0034-4885/75/11/116601 ↗
11. Eiraku · Nature · 2011 · 472 · 5110.1038/nature09941 ↗
12. Koehler · Nature · 2013 · 500 · 21710.1038/nature12298 ↗
13. W. P. Taylor , M.Schneider, H.Baltes and M. G.Allen, Transducers 97 - 1997 International Conference on Solid-State Sensors and Actuators, Digest of Technical Papers, Vol. 1 and 2, 1997, pp. 1445–1448
14. B. Alberts , A.Johnson, J.Lewis, M.Raff, K.Roberts and P.Walter, Mol. Biol. Cell, Garland Science, New York, 200710.1201/9780203833445 ↗
15. Puech · Ultramicroscopy · 2006 · 106 · 63710.1016/j.ultramic.2005.08.003 ↗
16. Wang · Sci. Rep. · 2016 · 6 · 2694510.1038/srep26945 ↗
17. Winkleman · Appl. Phys. Lett. · 2004 · 85 · 241110.1063/1.1794372 ↗
18. Neuman · Nat. Methods · 2008 · 5 · 49110.1038/nmeth.1218 ↗
19. Demirörs · Nature · 2013 · 503 · 9910.1038/nature12591 ↗