journal article·2024-08-12Open access

Influence of the configuration of metal sensing layers on the performance of a bimetallic (Ag–Cu) surface plasmon resonance biosensor

Anjitha M Pillai, Niveditha Nair, Mukul K Das, Sanjay K Ram

Nanotechnology· Volume 35· Issue 33

Abstract

Abstract Bimetallic surface plasmon resonance (SPR) sensors have the potential to overcome the drawbacks of individual metals, but the effect of the configuration of the two metallic layers on the performance of the sensors has not been explored. This study examines the influence of different positions of a thin layer of silver in relation to a copper layer on the sensitivity of such a bimetallic SPR sensor. The design of this configuration aims to improve the SPR reflectance curve and strengthen the evanescent electric field to improve the sensor efficiency. Our findings indicate that, by optimizing the architectures of SPR sensors and using a silver–copper bimetallic structure, we can achieve superior performance compared to devices that utilize only silver or copper. The optimized Ag (5 nm)/Cu (55 nm) sensor design, with the best sensitivity of 299.09° RIU−1, can detect a change of 0.43°/(g dl−1) for hemoglobin in blood, 0.35°/(g dl−1) for glucose in urine, and 0.1°/(%) for methanol in ethanol. We also demonstrate the importance of signal quality by introducing two new parameters that offer a better quantitative indication of the efficiency of a sensor than is obtained by using only sensitivity.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Plasmonic and Surface Plasmon Research · Advanced Biosensing Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Phase detection of surface plasmon resonance using rotating analyzer method10.1016/j.snb.2004.12.044 ↗
2. Surface plasmon studies of thin silver/gold bimetallic films10.1021/la00010a088 ↗
3. Bimetallic layers increase sensitivity of affinity sensors based on surface plasmon resonance10.3390/s20200062 ↗
4. Stable and sensitive silver surface plasmon resonance imaging sensor using trilayered metallic structures10.1021/ac402126k ↗
5. Effective refractive index and composition of oxidized porous silicon films10.1016/S0921-5107(99)00236-6 ↗
6. Enhanced biosensing activity of bimetallic surface plasmon resonance sensor10.3390/photonics6040108 ↗
7. Influences of surface roughness of ZnO electron transport layer on the photovoltaic performance of organic inverted solar cells10.1021/jp308480u ↗
8. Copper nitride nanowire arrays—comparison of synthetic approaches10.3390/ma14030603 ↗
9. Theoretical investigation of voltage sensitivity enhancement for surface plasmon resonance based optical fiber sensor with a bimetallic layer10.1016/j.optcom.2014.07.076 ↗
10. Bimetallic chips for a surface plasmon resonance instrument10.1364/AO.50.000387 ↗
11. Resonance effect of bimetallic diffraction grating on the sensing characteristics of surface plasmon resonance sensor with COMSOL multiphysics10.1166/jno.2019.2523 ↗
12. High performance SPR biosensor using Cu-Pt bimetallic layers and 2D materials10.15251/DJNB.2023.181.221 ↗
13. Sensitivity–stability-optimized surface plasmon resonance sensing with double metal layers10.1088/1464-4258/8/11/005 ↗
14. Resolution estimation of the Au, Ag, Cu, and Al single- and double-layer surface plasmon sensors in the ultraviolet, visible, and infrared regions10.1007/s11468-013-9575-1 ↗
15. Influence of the metal film thickness on the sensitivity of surface plasmon resonance biosensors10.1366/0003702053945994 ↗
16. Theoretical design of a surface plasmon resonance sensor with high sensitivity and high resolution based on graphene–WS2 hybrid nanostructures and Au–Ag bimetallic film10.1039/C7RA08380G ↗
17. Plasmonic properties of copper nanoparticles fabricated by nanosphere lithography10.1021/nl070648a ↗
18. Superior sensitivity of copper-based plasmonic biosensors10.1021/acs.langmuir.8b00276 ↗
19. Optical measurements of the surface plasmon of copper10.1002/pssb.2221070207 ↗
20. Design considerations for surface plasmon resonance based detection of human blood group in near infrared10.1063/1.3298503 ↗
21. SCHOTT n.d. Glass made of ideas (SCHOTT AG)
22. Self-consistent optical constants of SiO2 and Ta2O5 films10.1364/OME.6.003622 ↗
23. Realistic silver optical constants for plasmonics10.1038/srep30605 ↗
24. Optical constants of Cu, Ag, and Au revisited10.1364/AO.54.000477 ↗
25. Plasmonic nanomeshes: their ambivalent role as transparent electrodes in organic solar cells10.1038/srep42530 ↗
26. Sensitivity enhancement by using few-layer black phosphorus-graphene/TMDCs heterostructure in surface plasmon resonance biochemical sensor10.1016/j.snb.2017.04.110 ↗
27. Design of photonic crystal-based biosensor for detection of glucose concentration in urine10.1109/JSEN.2014.2359799 ↗
28. The refractive index of human hemoglobin in the visible range10.1088/0031-9155/56/13/017 ↗
29. Ultra sensitive long period fiber gratings based sensor for detection of adulterator in ethanol10.1364/CLEO_AT.2018.JW2A.170 ↗
30. COMSOL · 2019 · p 208
31. Sensitivity improved SPR biosensor based on the MoS2/graphene–aluminum hybrid structure J.10.1109/JLT.2016.2624982 ↗
32. Sensitivity enhancement in surface plasmon resonance sensors: theoretical modeling10.1117/12.820811 ↗
33. Dielectric coated plasmonic interfaces: their interest for sensitive sensing of analyte-ligand interactions10.1515/revac.2011.120 ↗
34. Hybrid design architecture and sensitivity analysis of Cu based surface plasmon resonance sensors
35. Plasmon resonance spectroscopy: probing molecular interactions within membranes10.1016/S0968-0004(99)01394-8 ↗
36. High-performance bimetallic film surface plasmon resonance sensor based on film thickness optimization10.1016/j.ijleo.2016.05.085 ↗
37. Studies of surface plasmon resonance effect on different metallic layers of silver (Ag) and copper (Cu) with molybdenum trioxide (MoO3) for formaldehyde sensor10.1016/j.rio.2023.100374 ↗
38. SPR bacterial pathogen biosensor: the importance of fluidic conditions and probing depth10.1016/j.talanta.2014.01.022 ↗
39. Surface plasmon resonance sensors: review10.1016/S0925-4005(98)00321-9 ↗