journal article·2022-09-10Open access

Comparative analysis of the sensitivity of nanometallic thin film thermometers

Ethan A Scott, Anna Carow, Douglas Pete, C Thomas Harris

Nanotechnology· Volume 33· Issue 37

Abstract

Abstract Thin film platinum resistive thermometers are conventionally applied for resistance thermometry techniques due to their stability and proven measurement accuracy. Depending upon the required thermometer thickness and temperature measurement, however, performance benefits can be realized through the application of alternative nanometallic thin films. Herein, a comparative experimental analysis is provided on the performance of nanometallic thin film thermometers most relevant to microelectronics and thermal sensing applications: Al, Au, Cu, and Pt. Sensitivity is assessed through the temperature coefficient of resistance, measured over a range of 10–300 K for thicknesses nominally spanning 25–200 nm. The interplay of electron scattering sources, which give rise to the temperature-dependent TCR properties for each metal, are analyzed in the framework of a Mayadas–Shatzkes based model. Despite the prevalence of evaporated Pt thin film thermometers, Au and Cu films fabricated in a similar manner may provide enhanced sensitivity depending upon thickness. These results may serve as a guide as the movement toward smaller measurement platforms necessitates the use of smaller, thinner metallic resistance thermometers.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor Technologies Research · Thermal properties of materials · Acoustic Wave Resonator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. On the extraction of resistivity and area of nanoscale interconnect lines by temperature-dependent resistance measurements10.1016/j.sse.2018.12.005 ↗
2. Advanced interconnects: materials, processing, and reliability10.1149/2.0271501jss ↗
3. Towards a robust thin film sensor for distinguishing fluids using the 3\omega-method10.1016/j.sna.2020.112419 ↗
4. Evaluation of uncertainty in determining average grain size by ASTM E112 standard10.1088/1757-899X/733/1/012045 ↗
5. Zum elektrischen Widerstandsgesetz bei tiefen Temperaturen10.1007/BF01341426 ↗
6. Development of a platinum resistance thermometer on the silicon substrate for phase change studies10.1088/0960-1317/22/8/085012 ↗
7. Surface and grain boundary contributions in the electrical resistivity of metallic nanofilms10.1016/j.tsf.2006.07.024 ↗
8. Ultrafast silicon nanomembrane microbolometer for long-wavelength infrared light detection10.1021/acs.nanolett.1c02972 ↗
9. The film thickness effect on electrical conduction mechanisms and characteristics of the ni–cr thin film resistor10.1109/JEDS.2016.2598189 ↗
10. Interconnect metals beyond copper: reliability challenges and opportunities10.1109/IEDM.2018.8614695 ↗
11. Reliable and accurate MEMS-based thermal conductivity characterization device for individual nanowires
12. Measuring the thermal conductivity of thin films: 3 omega and related electrical methods10.1615/AnnualRevHeatTransfer.v16.20 ↗
13. Temperature and size effect on the electrical properties of monolayer graphene based interconnects for next generation MQCA based nanoelectronics—scientific reports10.1038/s41598-020-63360-6 ↗
14. Highly scaled ruthenium interconnects10.1109/LED.2017.2709248 ↗
15. Thickness dependence of the resistivity of platinum-group metal thin films10.1063/1.4992089 ↗
16. The conductivity of thin metallic films according to the electron theory of metals10.1017/S0305004100019952 ↗
17. Electron mean free path in elemental metals10.1063/1.4942216 ↗
18. Die Abhaängigkeit des elektrischen Widerstandes reiner Metalle von der Temperatur10.1002/andp.19334080504 ↗
19. A PtNiGe resistance thermometer for cryogenic applications10.1063/5.0014007 ↗
20. Haynes · 2012
21. Environmentally sustainable composite resistors with low temperature coefficient of resistance10.1016/j.mee.2008.12.092 ↗
22. Thermal transport measurements of individual multiwalled nanotubes10.1103/PhysRevLett.87.215502 ↗
23. Dielectric barrier, etch stop, and metal capping materials for state of the art and beyond metal interconnects10.1149/2.0051501jss ↗
24. Kittel · 2004
25. High-sensitivity chip calorimeter platform for sub-nano watt thermal measurement10.1016/j.sna.2016.02.001 ↗
26. Size effect of the resistivity of thin epitaxial gold films10.1103/PhysRevB.70.165414 ↗
27. Electrical properties and reduced Debye temperature of polycrystalline thin gold films10.1088/0022-3727/43/46/465301 ↗
28. Electrical-resistivity model for polycrystalline films: the case of arbitrary reflection at external surfaces10.1103/PhysRevB.1.1382 ↗
29. Electrical resistivity model for polycrystalline films: the case of specular reflection at external surfaces10.1063/1.1652680 ↗
30. Electron scattering mechanisms in Cu–Mn films for interconnect applications10.1063/1.4893718 ↗
31. On errors in thermal conductivity measurements of suspended and supported nanowires using micro-thermometer devices from low to high temperatures10.1088/0957-0233/22/1/015103 ↗
32. Calculated thermal properties of metals10.1103/PhysRevB.37.790 ↗
33. Resistance scaling of Cu interconnect and alternate metal (Co, Ru) benchmark toward sub 10 nm dimension10.1109/IITC.2018.8430411 ↗
34. High resolution resistive thermometry for micro/nanoscale measurements10.1063/1.4744963 ↗
35. Measuring thermal and thermoelectric properties of one-dimensional nanostructures using a microfabricated device10.1115/1.1597619 ↗
36. Temperature-dependent resistivity of alternative metal thin films10.1063/5.0015048 ↗
37. Application of 3 omega method for thin-film heat flux gauge calibration10.1088/1361-6501/ac0f23 ↗
38. The mean free path of electrons in metals10.1080/00018735200101151 ↗
39. Evolution of microstructure in vanadium oxide bolometer film during annealing process10.1016/j.apsusc.2015.09.068 ↗
40. La1-x Sr x MnO3:Ag0.2 (0.1 ≤ x ≤ 0.2) ceramics with large room-temperature TCR for uncooled infrared bolometers10.1016/j.jeurceramsoc.2018.10.004 ↗
41. Atomic layer deposition synthesized TiOx thin films and their application as microbolometer active materials10.1116/1.4947120 ↗
42. Nano-thermoelectric infrared bolometers10.1063/5.0040534 ↗
43. Influence of polar solvent on the thermal conductivity of ionic liquid based on the developed two-wire 3ω method10.1016/j.molliq.2022.118674 ↗
44. Measuring nanowire thermal conductivity at high temperatures10.1088/1361-6501/aa9389 ↗
45. Electron beam evaporation deposition10.1002/9783527696406.ch2 ↗
46. Reexamination of thermal transport measurements of a low-thermal conductance nanowire with a suspended micro-device10.1063/1.4816647 ↗
47. Ruthenium metallization for advanced interconnects
48. Standard platinum resistance thermometer interpolations in a revised temperature scale10.1088/1681-7575/ab6b3c ↗
49. Large grain ruthenium for alternative interconnects10.1109/LED.2018.2879932 ↗
50. Influence of grain boundary scattering on the electrical properties of platinum nanofilms10.1063/1.2338885 ↗
51. A fast-response calorimeter with dynamic corrections for transient heat transfer measurements10.3390/app10176143 ↗
52. Analysis of the size effect in electroplated fine copper wires and a realistic assessment to model copper resistivity10.1063/1.2711385 ↗
53. Influence of the electron mean free path on the resistivity of thin metal films10.1016/j.mee.2004.07.041 ↗
54. Ziman · 2001