journal article·2008-06

Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography

M. Krumm, S. Kasperl, M. Franz

NDT & E International· Volume 41· Issue 4
Publisher page

Abstract

Abstract In computed tomography (CT) several physical effects reduce the quality of reconstructed CT images. Beside scatter, one major deterministic artifact is the beam hardening effect which arises due to the polychromatic character of the used X-ray spectrum and causes cupping and streak artifacts. In this paper, a method is proposed which allows correcting beam hardening artifacts in two and multi-component objects. Neither is it necessary to have any estimate or knowledge of the incident X-ray spectrum nor material characteristics like mass density or absorption coefficients. The method works without any reference measurements and uses the original projection images. Several two-material specimens of miscellaneous material combinations were tested and corrected to show the efficiency of the proposed method.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Kak · 1988
2. The fourier reconstruction of a head section10.1109/TNS.1974.6499235 ↗
3. Correction for beam hardening artefacts in computerised tomography
4. Correction for beam hardening in computed tomography10.1088/0031-9155/24/1/008 ↗
5. A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine10.1118/1.597970 ↗
6. CT reprojection polychromaticity correction for three attenuators10.1109/TNS.1981.4331811 ↗
7. A model-based correction method for beam hardening artefacts in X-ray microtomography
8. Kasperl S. Qualitätsverbesserungen durch referenzfreie Artefaktreduzierung und Oberflächennormierung in der industriellen 3D-Computertomographie. Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 2005.
9. Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography10.1118/1.2188076 ↗
10. Energy selective reconstructions in X-ray computerized tomography10.1088/0031-9155/21/5/002 ↗
11. Generalized image combinations in dual KVP digital radiography10.1118/1.595025 ↗
12. Fuchs TOJ. Strahlaufhärtungskorrekturen in der Computer-Tomographie. Inaugural-Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.
13. Post-reconstruction method for beam hardening in computerized tomography10.1088/0031-9155/24/2/009 ↗
14. Surface interpolation with radial basis functions for medical imaging10.1109/42.552059 ↗
15. Device modeling by radial basis functions10.1109/81.109239 ↗
16. Wenig P. Untersuchung von Störeinflüssen auf das dimensionelle Messen mittels Röntgencomputertomographie. Diplomarbeit, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.