Time-frequency characteristics of longitudinal modes in symmetric mode conversion for defect characterization in guided waves-based pipeline inspection
Source abstract
Abstract
Abstract The converted modes generated by mode conversion in guided waves-based inspection can provide plenty of defect information, and the reasonable usage of multiple wave modes can improve the results of defect inspection and evaluation. Axisymmetric longitudinal L(0,2) mode guided-waves is widely used in pipeline inspection currently, and the lower order longitudinal L(0,1) mode is easily excited simultaneously. This paper focuses the interconversion process of axisymmetric modes for incident longitudinal modes when interacting with the defects in pipeline whist ignoring the converted non-axisymmetric modes through suppressing them in reception. This process is defined as symmetric mode conversion in this research. The pattern of axisymmetric mode sequence during symmetric mode conversion is identified and the method is proposed to extract the converted axisymmetric mode components for analysis. The relationships between the defect features and the modes generated in symmetric mode conversion under the excitation of longitudinal mode waves are investigated. The conclusion obtained by numerical simulation is also experimentally verified using guided wave data from practical pipeline. The results show that longitudinal modes in symmetric mode conversion present the useful time and frequency characteristics, which provides the potential for establishing an effective defect inspection and evaluation method with longitudinal guided waves.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Geophysical Methods and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Defect detection in pipes using guided waves[J]10.1016/S0041-624X(97)00038-3 ↗
2. The choice of ultrasonic inspection method for the detection of corrosion at inaccessible locations[J]10.1016/j.ndteint.2018.06.003 ↗
3. Review of guided-wave structural health monitoring10.1177/0583102406075428 ↗
4. Guided wave generation, sensing and damage detection using in-plane shear piezoelectric wafers10.1088/0964-1726/23/1/015014 ↗
5. Monitoring of corrosion in pipelines using guided waves and permanently installed transducers10.1121/1.4755100 ↗
6. A baseline and vision of ultrasonic guided wave inspection potential [J]10.1115/1.1491272 ↗
7. Review of synthetically focused guided wave imaging techniques with application to defect
8. Determination of natural frequencies of pipes using white noise for magnetostrictive longitudinal guided-wave nondestructive testing[J]10.1109/TIM.2019.2931528 ↗
9. Guided wave signal processing and image fusion for in situ damage localization in plates[J]10.1016/j.wavemoti.2007.02.008 ↗
10. Phased annular array transducers for omnidirectional guided wave mode control in isotropic plate like structures[J]10.1088/0964-1726/22/12/125022 ↗
11. Sizing of impact damages in composite materials using ultrasonic guided waves[J]10.1016/j.ndteint.2011.10.002 ↗
12. Mode separation and characterization of torsional guided wave signals reflected from defects using chirplet transform[J]10.1016/j.ndteint.2015.04.006 ↗
13. Subwavelength defect characterization using guided wave scattering matrix[J]10.4028/www.scientific.net/AMM.330.504 ↗
14. The reflection of guided waves from notches in pipes: a guide for interpreting corrosion measurements[J]10.1016/j.ndteint.2003.09.004 ↗
15. Experimental investigation of the reflection in guided Wave-based Inspection for the characterization of pipeline defects[J]10.1016/j.ndteint.2010.01.002 ↗
16. Fatigue crack detection in pipes with multiple mode nonlinear guided waves[J]10.1177/1475921718791134 ↗
17. Multiridge-based analysis for separating individual modes from multimodal guided wave signals in long bones[J]10.1109/TUFFC.2010.1714 ↗
18. Sparse recovery of multiple dispersive guided-wave modes for defect localization using a Bayesian approach[J]10.1177/1475921718790212 ↗
19. Ultrasonic waveguide based level measurement using flexural mode F(1,1) in addition to the fundamental modes [J]
20. Estimation of ultrasonic guided wave mode conversion in a plate with thickness variation[J]10.1109/58.842046 ↗
21. The mode conversion of a guided wave by a part-circumferential notch in a pipe[J]10.1115/1.2789107 ↗
22. Time-domain spectral finite element method for analysis of torsional guided waves scattering and mode conversion by cracks in pipes[J]10.1016/j.ymssp.2019.04.013 ↗
23. Investigation on ultrasonic guided waves propagation in elbow pipe[J]10.1016/j.ijpvp.2016.02.026 ↗
24. The choice of torsional or longitudinal excitation in guided wave pipe inspection[
25. Pipe wall damage detection by electromagnetic acoustic transducer generated guided waves in absence of defect signals[J]10.1121/1.2902188 ↗
26. Extracting quantitative information on pipe wall damage in absence of clear signals from defect[J]10.1115/1.4005877 ↗
27. Interaction of SH guided waves with wall thinning[J]10.1016/j.ndteint.2018.10.007 ↗
28. Mode selectivity of SH guided waves by dual excitation and reception applied to mode conversion analysis[J]10.1109/TUFFC.2018.2835299 ↗
29. The reflection of guided waves from circumferential notches in pipes[J]10.1115/1.2789105 ↗
30. Rose · 1999
31. Guided wave signal processing and image fusion for in situ damage localization in plates[J]10.1016/j.wavemoti.2007.02.008 ↗
32. Phased annular array transducers for omnidirectional guided wave mode control in isotropic plate like structures[J]10.1088/0964-1726/22/12/125022 ↗
33. Enhancement of unidirectional excitation of guided torsional T(0,1) mode by linear superposition of multiple rings of transducers[J]10.1016/j.apacoust.2020.107411 ↗
34. A two-dimensional Fourier transform method for the measurement of propagating multimode signals[J]10.1121/1.400530 ↗
35. The interaction of Lamb waves with defects[J]10.1109/58.143172 ↗
36. Characterization of pipeline defect in guided-waves based inspection through matching pursuit with the optimized dictionary[J]10.1016/j.ndteint.2012.10.003 ↗
37. The variation of the reflection coefficient of extensional guided waves in pipes from defects as a function of defect depth, axial extent, circumferential extent and frequency[J]10.1243/095440602761609498 ↗
38. Guided wave thickness measurement with EMATs[J]10.1784/insi.45.11.735.52961 ↗
39. Identification and analysis of multimode guided waves in tibia cortical bone[J]10.1016/j.ultras.2006.06.013 ↗