journal article·2009-01

Design of modified electromagnetic main-flux for steel wire rope inspection

C. Jomdecha, A. Prateepasen

NDT & E International· Volume 42· Issue 1
Publisher page

Abstract

Abstract This paper presents the design and construction of modified main-flux equipment for wire rope inspection which has advantages over the in-service inspection and indirect axial-flux measurement used by ordinary main-flux and return-flux methods. The equipment can be adjusted high electromagnetic field strength to produce leakage filed from flaws of various large-diameter ropes. Unique coil sensors connected in series were employed and performed well when sensing leakage fields of the radial, axial and tangential directions. In addition, a standalone system has a simple setup for service inspection. Due to the complicated structure of the wire rope, electromagnetic field theory for anisotropic structures with high electromagnetization was used to design the equipment. The characteristics of the leakage field, in terms of localized fault and loss of metallic cross-sectional area, were distinguished mathematically. The sensor orientation to detect leakage fields was also determined. Performance of the system was then verified experimentally and shown good resolution and repeatability. Furthermore, the equipment is sufficiently sensitive to detect a smallest surface flaw of 1×2 mm at 5 mm equipment lift off. The inspection signals were processed and shown locations, levels and deterioration quantities.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. The inspection of wire ropes in service: a critical review
2. Whitehead EAN. Method of obtaining an electrical signal proportional to the cross-sectional area of a magnetic tube or rod. UK Patent 913,780, 1962.
3. Standard practice for electromagnetic examination of ferromagnetic steel wire rope
4. The principle and application of a new technique for detecting wire rope defects
5. Weischedel HR. The magnetic flux leakage inspection of wire ropes. NDT Technologies Inc., p. 1–19.
6. Design and construction of magnetic-flux-leakage equipment for detecting localized faults of wire rope
7. Jomdecha · 2002
8. Characterization of wire rope defects from magnetic flux leakage signals
9. Characterisation of metal loss defects from magnetic flux leakage signals with discrete wavelet transform10.1016/S0963-8695(99)00011-0 ↗
10. Electromagnetic response of an isotropic conducting cylinder to an external source10.1029/RS013i005p00789 ↗
11. Wangsness · 1979
12. Wait · 1985
13. A transducer made up of fluxgate sensors for testing wire rope defects10.1109/19.989914 ↗
14. Jomdecha C, Prateepasen A, Methong W. Coil sensors for wire rope inspection using magnetic flux leakage instrument. In: ICCAS 2002, Muju Resort, Jeonbuk, Korea; 2002. p. 1131–6.